http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Abciximab(ReoPro)부착 관상동맥 스텐트의 세포외 기질 및 고사에 대한 영향
홍영준,정명호,안영근,임상엽,홍서나,이상현,김계훈,윤경호,강동구,이연상,박형욱,김주한,조정관,박종태,박창수,박종춘,강정채 대한심장학회 2005 Korean Circulation Journal Vol.35 No.4
Background and Objectives:The most important mechanism of coronary stent restenosis is neointimal hy-perplasia (NIH). In addition to neointimal cell proliferation, synthesis of the extracellular matrix (ECM) may be important for the induction of NIH. The efects of the abciximab (ReoPro)-coated stent on the ECM synthesis and cellular apoptosis in coronary stent restenosis were observed. Materials and Methods:Twenty one abcixi-mab-coated stents and 21 control stents were placed in porcine coronary arteries and histopathologic analyses were performed at 14 days, 28 days and 56 days after the stenting procedures, respectively. Each specimen was analyzed by hematoxylin and eosin staining, modified Movat, immunohistochemical staining and TUNEL analysis. Results:The area of neointima in the abciximab-coated stents was reduced by 45.7% and 45.5% of the control stents at 28 days and 56 days after stenting, respectively (1.9± 0.5 vs. 3.5± 0.7 mm2, 2.4± 0.5 vs. 4.4± 0.6 mm2, p= 0.012, 0.001, respectively). The content ratio of the proteoglycan of the abciximab-coated stents was reduced by 23% at 14 days (12.4± 4.4 vs. 16.1± 4.3%, respectively, p= 0.041)collagen in the abciximab-coated stents was reduced by 19.7% and 25% at 28 days and 56 days, respectively (27.7± 5.0 vs. 34.5± 8.7%, 36.6± 10.5 vs. 48.8± 12.7%, p= 0.021, 0.001, respectively). The proliferating cell nuclear antigen index of neointima for the abciximab-coated stents was reduced by 22.2% at 14 days (10.5± 5.4 vs. 13.5± 8.4%, respectively, p= 0.022)by TUNEL analysis between the two groups on the 56-day follow-up after stenting. Conclusion:The Abciximab-coated stent inhibits ECM synthesis, but it does not inhibit apoptosis in a porcine stent restenosis model. 배경 및 목적: 돼지 관상동맥에 혈소판 당단백 IIb/IIIa 수용체 차단제인 abciximab 부착 스텐트(ReoPro??-coated stent)와 대조 스텐트를 시술 후 시간경과에 따른 세포 증식률 및 세포외 기질의 분포와 스텐트 재협착의 형성과의 관계를 알아보고자 하였다. 방 법: 돼지 관상동맥 재협착 모형을 이용하며 abciximab 부착 스텐트 21개와 대조 스텐트 21개를 삽입하여 14일, 28일,56일째에 희생시켜 조직학적인 비교를 실시하였다. 혈관은 파라핀 포매괴를 만들고 박절편에서 Hematoxylin and Eosin 염색을 실시하고 세포외기질 성분에 대해 Masson Trichrome 염색을 실시하여 리오프로 부착 스텐트의 시간경과에 따른 세포외기질에 대한 영향을 분석하였고, proliferating cell nuclear antigen(PCNA)과 평활근 α-actin에대한 단클론 항체를 이용한 면역 조직 화학 염색법을 이용하여 리오프로 부착 스텐트가 세포증식 및 혈관 평활근 세포 증식에 미치는 영향을 조사하였으며 세포 고사에 대해서는 TUNEL 분석을 실시하였고 분석에는 Visus 2000 Visual Image Analysis system을 이용하였다. 결 과: 관상동맥 혈관 세포 손상 지수는 양 군에서 차이가 없었고 신생내막의 영역은 abciximab 스텐트 군에서 대조 스텐트 군에 비해 28일째 45.7%, 56일째 45.5% 각각 감소하였고(1.9±0.5 vs. 3.5±0.7, 2.4±0.5 vs. 4.4±0.6 mm2, 각각 p=0.012, 0.001), 내강 협착률은 abciximab 스텐트 군에서 대조 스텐트 군에 비해 28일째 48%, 56일째 48.1% 감소하였다(21.8±6.2 vs. 42.1±13.2, 28.2±10.4 vs. 54.3±18.4%, 각각 p=0.001, 0.001). 신생내막 내 proteoglycan의 비율은 abciximab 스텐트 군에서 대조 스텐트 군에 비해 14일째 23% 감소하였고(12.4±4.4 vs. 16.1±4.3%, p=0.041), 신생내막 내 collagen의 비율은 abciximab 스텐트군에서 대조 스텐트 군에 비해 28일째 19.7%, 56일째 25% 감소하였다(27.7±5.0 vs. 34.5±8.7, 36.6±10.5 vs. 48.8±12.7%, 각각 p=0.021, 0.001). PCNA 양성 세포의 비율은 abciximab 스텐트 군에서 대조 스텐트 군에 비해 14일째 22.2% 감소하였다(10.5±5.4 vs. 13.5±8.4%, p=0.022).신생내막 내 세포들에서 평활근 α-actin 양성을 나타내었고 이는 스텐트 삽입 후 주수에 따라 증가하였으며 abciximab 스텐트 군에서 대조 스텐트 군에 비해 낮은 경향을 보였다. 신생내막 내 고사 세포의 비율은 14일, 28일, 56일째에 abciximab 스텐트 군이 각각 25.9±10.1, 34.2±12.9, 44.4±17.3%, 대조 스텐트 군이 각각 22.5±11.0, 30.6±13.2, 40.2±19.8%로서 세포고사에 있어서 양군 간에 유의한 차이는 없었다. 결 론: Abciximab(ReoPro??) 부착 스텐트는 세포 증식과 세포외기질형성을 억제하였으나 세포 고사에는 영향이 없었다.
배드민턴 선수가 인식하는 지도자의 자율성지지와 운동탈진의 관계에서 운동정서의 매개효과
홍영준,최유리 한국스포츠학회 2022 한국스포츠학회지 Vol.20 No.3
The purpose of this study was to investigate the parallel multi-mediating effect of Athletic Emotions on the Relationship between Leader's Autonomy Support and Exercise Exhaustion in Badminton Players. In order to achieve the purpose of the study, the data of 255 badminton players registered as players in the Korean Sports Council in 2022. The collected data were analyzed through descriptive statistics, reliability test, exploratory factor analysis, correlation analysis, and model 4 of the PROCESS macro (v.3.3) using the SPSS 23.0 program, and the results are as follows. First, positive emotion, was found to mediate the relationship between autonomy support and emotional/physical exhaustion. Second, both positive and negative emotions, were found to mediate the relationship between autonomy support and exhaustion of a sense of achievement. Third, positive emotion, was found to mediate the relationship between autonomy support and devaluation. It was found that the coach's support for autonomy perceived by the players mediates athletic emotion and reduces exercise exhaustion. In addition, positive emotions experienced by athletes decreased exercise exhaustion, and negative emotions increased exercise exhaustion, indicating that exercise emotion and exercise burnout are closely related. To summarize the results of the study, it is effective for the coach to maintain a positive emotion by autonomy supporting the of the athletes in order to reduce the athletes' exhaustion. 본 연구는 배드민턴 선수가 인식하는 지도자의 자율성지지와 운동탈진의 관계에서 운동정서의 병렬다중매개효과를 알아보는데 목적이 있었다. 연구의 목적을 달성하기 위하여 2022년 대한체육회에 선수로 등록되어 있는 배드민턴 선수 255명의 자료를 수집하였다. 수집된 자료는 SPSS 23.0 프로그램을 활용하여 기술통계, 신뢰도 검사, 탐색적 요인분석, 상관관계 분석과 PROCESS macro(v.3.3)의 모델 4를 통해 분석을 실시하였으며, 그 결과는 다음과 같다. 첫째, 운동정서의 하위요인 긍정정서는 자율성지지와 정서/신체 소진의 관계를 매개하는 것으로 나타났다. 둘째, 운동정서의 하위요인 긍정정서와 부정정서 모두 자율성지지와 성취감 소진의 관계를 매개하는 것으로 나타났다. 셋째, 운동정서의 하위요인 긍정정서는 자율성지지와 평가저하의 관계를 매개하는 것으로 나타났다. 선수들이 인식하는 지도자의 자율성지지는 운동정서를 매개하여 운동탈진을 감소시키는 것으로 나타났다. 또한, 선수가 경험하는 긍정정서는 운동탈진을 감소시키고, 부정정서는 운동탈진을 높이는 것으로 나타나 운동정서와 운동탈진은 밀접한 관련이 있는 것으로 나타났다. 연구결과를 종합해보면, 선수들의 운동탈진을 감소시키기 위해서는 지도자는 선수들에게 자율성을 지지하여 긍정정서를 유지하는 것이 효과적이다.
차세대 리소그래피 빛샘 발생을 위한 플라스마 집속장치의 아르곤 아크 플라스마의 방출 스펙트럼 진단
홍영준,문민욱,이수범,오필용,송기백,홍병희,서윤호,이원주,신희명,최은하,Hong, Y.J.,Moon, M.W.,Lee, S.B.,Oh, P.Y.,Song, K.B.,Hong, B.H.,Seo, Y.H.,Yi, W.J.,Shin, H.M.,Choi, E.H. 한국진공학회 2006 Applied Science and Convergence Technology Vol.15 No.6
차세대 리소그래피 기술인 극자외선(EUV : Extreme Ultraviolet) 빛샘 연구의 기초단계로써, 동축타입의 전극구조가 설치된 다이오드 챔버를 통해 Ar 플라스마를 생성하였으며, 방출 분광기술(emission spectroscopy)를 이용하여 방출된 가시광선 영역의 빛을 조사하였다. 장치의 입력 전압을 0.5kV씩 변화를 주어 $2\sim3.5kV$까지 인가를 했으며 이극챔버의 최적 압력인 330mTorr 일 때 각 전압에 따른 방출 분광선 데이터를 얻었다. 이때 Ar I과 Ar II 방출선을 관측하였으며 국소적인 열적평형 (LTE ; Local Thermodynamic Equilibrium) 상태의 가정 하에 볼츠만 도표(Boltzmann plot)와 사하(Saha) 방정식을 이용해 Ar I 및 Ar II의 전자온도와 이온 밀도를 각각 계산하였다. 각 입력전압에 대해 이온밀도는 Ar I과 Ar II에서 각각 $\sim10^{15}/cc$ 및 $\sim10^{13}/cc$의 값으로 계산되었다. We have generated the argon plasma in the diode chamber based on the established coaxial electrode type and investigated the emitted visible light for emission spectroscopy. We applied various voltages $2\sim3.5kV$ to the device by 0.5kV, and obtained the emission spectrum data for the focused plasma in the diode chamber on the argon pressure of 330 mTorr. The Ar I and Ar II emission line are observed. The electron temperature and ion density have been measured by the Boltzmann plot and Saha equation from assumption of local thermodynamic equilibrium (LTE) The Ar I and Ar II ion densities have been calculated to be $\sim10^{15}/cc\;and\;~10^{13}/cc$, respectively, from Saha equation.