http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
유관우,이병문,강운구 한국컴퓨터정보학회 2022 韓國컴퓨터情報學會論文誌 Vol.27 No.12
In this paper, we propose a design of CCTV enlcosure record management system based on blockchain. Since CCTV video records are transferred to the control center through enclosure, it is very important to manage the enclosure to prevent modulation and damage of the video records. Recently, a smart enclosure monitoring system with real-time remote monitoring and opening and closing state management functions is used to manage CCTV enclosures, but there is a limitation to securing the safety of CCTV video records. The proposed system detect modulated record and recover the record through hash value comparison by distributed stored record in the blockchain. In addition, the integrity verification API is provided to ensure the integrity of enclosure record received by the management server. In order to verify the effectiveness of the system, the integrity verification accuracy and elapsed time were measured through experiments. As a result, the integrity of enclosure record (accuracy: 100%) was confirmed, and it was confirmed that the elapsed time for verification (average: 73 ms) did not affect monitoring. 본 연구에서는 공공 CCTV 함체 관리를 위한 블록체인 기반 함체기록 관리 시스템을 설계하였다. CCTV 영상 기록은 함체를 거쳐 관제센터까지 전송되기 때문에 영상기록의 변조 및 훼손 방지를 위한함체 관리가 매우 중요하다. 최근 CCTV 함체 관리를 위해 실시간 원격 모니터링 및 개폐 상태 관리기능을 갖춘 스마트 함체 모니터링 시스템을 사용하고 있으나 CCTV 영상기록의 안전성 확보에는 한계가있다. 우리가 제안한 시스템은 함체기록을 블록체인에 분산 저장하여 해시값 비교를 통해 위조를 탐지하고위조된 함체기록을 복구할 수 있다. 또한 관리서버가 수신하는 함체기록의 무결성을 확인할 수 있도록무결성 검증 API를 제공하여 함체기록의 무결성을 보장한다. 제안 시스템의 효용성을 검증하기 위해실험을 통해 무결성 검증 정확도와 소요시간을 측정하였다. 실험 결과 함체기록의 무결성(정확도: 100%)을확인하였고, 검증 소요시간(평균: 73ms)이 모니터링에 영향을 미치지 않을 것으로 확인하였다.
Telescopic 증폭기를 이용한 고속 LVDS I/O 인터페이스 설계
유관우,김정범 강원대학교 정보통신연구소 2007 정보통신논문지 Vol.11 No.-
This paper presents the design of input/output (I/O) interface circuits for 2.5Gbps operation in a 3.3V 0.35m CMOS technology. Due to the differential transmission technique and low voltage swing, LVDS (low-voltage differential signaling) has been widely used for high speed transmission with low power consumption. This interface circuit is fully compatible with the LVDS standard. The LVDS proposed in this paper utilizes a telescopic amplifier. This circuit operated up to 2.5Gbps. The circuit exhibits a power consumption of 21.04mW.
DAG 블록체인 기반의 향상된 CCTV 함체기록 관리모델
유관우,이병문 한국멀티미디어학회 2023 멀티미디어학회논문지 Vol.26 No.8
Managing enclosures is necessary in order to safely transfer video stream of public CCTV. Smart enclosure monitoring system provides efficient management by providing operating status and environment of enclosures and blockchain based enclosure record management system provides data integrity to this end. However, the blockchain with linear structure has a limit on data rate for storing depending on the block generation cycle and size. If the amount of data over this limit, a bottleneck occurs. The bottleneck reduces availability of the system. Therefore, this paper proposes a directed acyclic graph blockchain based CCTV enclosure record management model to reduce the bottleneck. This model stores the record in blockchain of DAG structure and maintains its integrity. The blockchain increases throughput and reduces the bottleneck of the linear blockchain by storing multiple blocks at the same time. To evaluate the performance of this model, an experiment simulating the confirmation time of linear and DAG blockchain was conducted. As a result the linear blockchain showed a maximum time of 859 seconds and the DAG blockchain showed a maximum time of 12.9 seconds in an environment composed of 1500 nodes, confirming that the bottleneck was reduced.
Telescopic 증폭기를 이용한 고속 LVDS I/O 인터페이스 설계
유관우,김정범 대한전자공학회 2007 電子工學會論文誌-SD (Semiconductor and devices) Vol.44 No.6
본 논문은 3.3V, 0.35㎛ CMOS 기술을 이용하여 I/O 인터페이스를 설계, 검증하였다. LVDS (low-voltage differential signaling)는 차동전송 방식과 저 전압의 스윙으로 저 전력 고속의 데이터를 전송할 수 있다. 본 논문은 기존의 차동증폭기나 감지 증폭기를 사용한 LVDS와 달리 telescopic 증폭기를 이용하여 2.3 Gbps의 빠른 전송속도를 갖는 LVDS 고속 인터페이스를 구현하였다. LVDS의 표준을 모두 충족하였고 25.5 mW의 전력소모를 갖는다. 이 회로는 삼성 0.35㎛ CMOS 공정을 이용하여 설계하였으며, HSPICE를 통하여 검증하였다. This paper presents the design and the implementation of input/output (I/O) interface circuits for 2.5 Gbps operation in a 3.3V 0.35um CMOS technology. Due to the differential transmission technique and low voltage swing, LVDS (low-voltage differential signaling) has been widely used for high speed transmission with low power consumption. This interface circuit is fully compatible with the LVDS standard. The LVDS proposed in this paper utilizes a telescopic amplifier. This circuit is operated up to 2.3 Gbps. The circuit has a power consumption of 25.5 mW. This circuit is designed with Samsung 0.35 ㎛ CMOS process. The validity and effectiveness are verified through the HSPICE simulation.
구관우,강신광,원태희,김시욱,유재현,나명훈,임승평,이영 대한흉부외과학회 2002 Journal of Chest Surgery (J Chest Surg) Vol.35 No.10
Cardiac Malignant Mesenchymoma - Two Cases Report - 원발성 심장 종양은 드물며 이들 중 20~25%에서 악성 종양이다. 더욱이 심장에서의 원발성 악성 간엽세포종은 극히 드문데, 최근 저자 등은 2례의 심장 악성 간엽세포종을 경험하였다.첫 번째 예는 승모판 폐쇄부전증을 보인 61세의 여자환자로 승모판을 막고있는 좌심방의 후측벽에서 생긴 악성 간엽세포종이었다. 2.7×3.7cm 크기의 종괴는 승모판의 후내측 교련과 판륜까지 자라고 있었다. 좌심방의 벽측은 남긴채 종괴는 부분 절제하였다. 환자는 항암치료를 받고 30일 후에 별문제 없이 퇴원하였으며, 19개월 동안 외래 추적관찰 중이다.두 번째 예는 좌측 하폐정맥에서 기원한 4×5cm 크기의 약하고 연노란색의 다엽성의 종괴였다. 다른 작은 종양결절들이 좌심방의 벽과 승모판 후엽에서 발견되었다. 수술은 종양의 부분절제와 승모판막치환술을 시행하였다.
영구 경정맥 심박조율도관의 심장내 이동과 동반된 심내막염 -1례 보고-
구관우,강신,김시욱,유재현,나명훈,임승평,이영 대한흉부외과학회 2002 Journal of Chest Surgery (J Chest Surg) Vol.35 No.11
감염된 심박조율기의 부분적 제거 후에 발생되는 재감염율은 51%에서 77%에 이르기 때문에 심박조율기의 어느 부위라도 감염이 된다면 모든 심박조율기의 하드웨어는 제거되어야 한다. 심폐기 가동하에서 감염된 심박조율기를 제거하는 것은 감염과 증식물의 확산 뿐만 아니라 기계적 손상을 방지 할 수 있다. 저자 등은 좌쇄골하 정맥에서 심장내로 이동된, 감염된 경정맥 심박조율기 도관에 의해 발생한 심내막염의 1예를 보고한다. 심장내로 이동된 심박조율기 도관과 증식물이 부착된 전극은 심폐우회를 이용하여 제거하였다.영구적 심내 심박조율기 설치에 따른 합병증이 다양하고 발생 빈도가 높기 때문에 이식한 심박조율기의 수명을 연장시키고 심박조율기 기능이상을 사전에 알아내기 위한 환자의 추적 관리가 필수적이다. 근자에 와서 심박조율기의 이식이 증가함에 따라 심박조율기 clinic이 설치되어 정기적 심전도 모니터, X-선 검사, 전해질의 측정 등을 하고 있으며, 또한 transtelephone을 이용하여 환자와 의사간의 편리를 도모하고 있는 추세이다7). Endocarditis with Intracardiac Migration of TransvenousPermanent Pacing Lead- 1 Case Report -