http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
응축전열관 외부형상 변화에 따른 HFC134a의 열전달 실험
박찬형,이영수,정진희,강용태 대한설비공학회 2006 설비공학 논문집 Vol.18 No.8
The objectives of this paper are to study the characteristics of heat transfer for enhanced tubes(19.05mm) used in the condenser with high saturation temperatures and to provide a guideline for optimum design of a condenser using HFC134a. Three different enhanced tubes are tested at a high saturation temperature of 59.8℃(16bar); a low-fin and three turbo-C tubes.. The refrigerant, HFC134a is condensed on the outside of the tube while the cooling water flows inside the tube. The film Reynolds number varies from 130 to 330. The wall subcooling temperature ranges from 2.7℃ to 9.7℃. This study provides experimental heat transfer coefficients for condensation on the enhanced tubes. It is found that the turbo- C(2) tube provides the highest heat transfer coefficient.