김영민(Young-min Kim),강희정(Hee-jung Kang),방상우(Sang-woo Bang),임영도(Young-do Lim) 한국정보기술학회 2010 한국정보기술학회논문지 Vol.8 No.5
Generally parking of the vehicle only driver sight and in compliance with an experience comes to do the spatial security which is caused by with judging distance and the camera which are accurate the various sensor, but it in recent times is caused by with technical advancement and leads was possible, parking was quicker and safely there made be a possibility of doing. So about unmanned parking the research vehicle with technical advancement and in standard to be advanced from the side which is various comes. In this paper the parking sector from the public parking lot or the formation parking market is clear and importance in the space where the unmanned camera is established in the parking sector depends in real-time image value and is parks autonomously. The camera which is established in the parking sector guard and the vehicle of parking space, recognized the object with real-time image processing and the vehicle wheel track angle in compliance with a image data and presumed Fuzzy-control led and in the four-wheel mobile robot and parking a production value and got applied accomplished.
한국인에 발생한 기저세포 모반 증후군 : REVIEW OF 33 AFFECTED KOREAN INDIVIDUALS
임영신,김도경,김수관,윤정훈 大韓顎顔面成形再建外科學會 2003 Maxillofacial Plastic Reconstructive Surgery Vol.25 No.4
Basal cell nevus syndrome(BCNS)is a hereditary condition transmitted as an autosomal dominant trait that exhidits high penetrance and variable expressivity. There ara many potential complications which have been reported in association with the naevoid basal cell carcinoma syndrome. The data upon which this review is based has been retrieved from published case reports in Korean dental and medical literatures between the years 1981 to 2002. this survey included unpublished 3 patients by reviewing patients files and charts from the Dental hospital, Chosun University during same periods. We found 33 subjects who met the diagnostic criteria for BCNS reported by Evans et al. Relative frequencies of associated complications are presented and compared with those of the recent English survey. The frequencies of most manifestations are similar. Odontogenic keretocyst (OKC)and palmar and/or plantar pits, and hypertelorism were the most frequently observed anomalies. OKCs are often the first signs of BCNS and can be detected in patients younger than 9 years of age. however, the relatively low frequency of basal cell carcinomas and ectopic calcification were two major difference. This study more clearly defines the possible complications of the syndrome and gives earlier guidelines for counselling and screening affected and at risk persons.
12-O-Tetradecanoylphorbol-13-Acetate에 의한 HL-60 세포 분화유도중 Vimentin 유전자 전사조절에 대한 AP-1의 역할
임규,김진희,권도원,김승민,이명선,윤경아,손미영,박종일,윤완희,황병두 충남대학교 생물공학연구소 1999 생물공학연구지 Vol.7 No.-
Purpose: To gain insight on the role of AP-1 in transcriptional regulation of vimentin gene during differentiation of HL-60 cells by 12-O-tetradecanoylphorbol-13-acetate (TPA), the levels of vimentin mRNA and AP-1 have been investigated with Northern blot hybridization and DNA mobility shift assay. Materials and Methods: HL-60 cells were grown in RPMI 1640 medium supplemented with 10% heat-inactivated fetal calf serum and antibiotics in a humidified 5% CO_2 at 37℃. Total RNA was prepared by a modification of the method of Karlinsey et al. Northern blot hybridization was performed by the method of Virca et al. EcoRI fragment of pVIM-GEM was used as probe for vimentin mRNA. DNA mobility shift assay was performed by the method of Lim et al. End labeled DNA probe(Upper strand, 5'-CGCTTGATGAGTCAGCCG- 3') for AP-1 binding activity was mixed with nuclear extracts in a 20 μl reaction volume containing 300 mM KCI, 60 mM HEPES, pH 7.9, 25 mM MgCI_2, 1 mM EDTA, 1 mM DTT, 60% glycerol, and 2 ㎍ of poly[dI-dC]. Results: TPA increased vimentin mRNA levels, with maximal stimulation reached at 24 hr. The level of vimentin mRNA was induced in proportion to the concentration of TPA. TPA-induced vimentin mRNA was almost reduced by actinomycin-D pretreatment. TPA-induced stimulation of vimentin gene was completely reduced by staurosporin pretreatment. In DNA mobility shift assay, AP-1 newly appeared at 24 hr during TPA-induced differentiation and was almost not detected after the pretreatment of staurosporin. Conclusions: These results suggest that the induction of vimentin mRNA during TPA-dependent differentiation in HL-60 cells may be mediated by protein kinases C signal transduction and AP-1 is important to transcriptional regulation.
임영도,설재훈,한창훈,김승철,박종오,이준탁,방석원 東亞大學校 附設 情報通信硏究所 1998 情報通信硏究所論文誌 Vol.6 No.1
This paper describes an intelligent cruise control system for automobile. With the remarkable numericalincrease of automobiles on the roal, the optimized traffic flow control using the cruise control is one of the very important traffic problems to overcome the limitation of an existing road capacity. Based onthis idea that minimize the fuel cost and teh air pollution, and accept a driver's needs for driving, we have developed an intelligent cruise control system for vehicle. This proposed intelligent fuzzy cruise controller was successfully implemented using the fuzzy algorithm, the i80c196 μ-controller board and the throttle valve actuator. The field test results on an linear road was introduced.
후두 및 하인두 편평세포암종에서 E-cadherin의 면역조직화학적 발현
도남용,나한조,이도용,허준,최지윤,이홍영,임성철 조선대학교 2000 The Medical Journal of Chosun University Vol.25 No.2
Background and Objectives : The cell-cell adhesion molecule E-cadherin is necessary for the maintenance of the epithelial cellular structure. We were designed to confirm the significance of E-cadherin as a marker for differentiation and invasiveness of squamous cell carcinoma of the larynx and hypopharynx. Materials and Methods : Our study was investigated for the immunohistochemical expression of the epithelium-specific cell adhesion molecule E-cadherin in formalin fixed paraffin embedded tissue specimen of 32 cases of squamous cell carcinoma of larynx and hypopharynx. Results : The positive expression of E-cadherin was 56.3%(18 cases) in squamous cell carcinoma of the larynx and hypopharynx. Decreased E-cadherin expression was a stastistically significant correlation with a increased grade of lymph node stage and clinical stage. Reduced expression was seen in the large tumor size and poorly differentiated tumors, but these result was not statistically significant. Conclusion : The expression of E-cadherin may be related with progression of squamous cell carcinoma of the larynx and hypopharynx. But these correlation were not sufficient for the prognostic indicators in squamous cell carcinomas of the larynx and hypopharynx.
임동건,정세민,최유신,김도영,이준신 성균관대학교 1997 학술회의지원논문목록집 Vol.1997 No.-
We have investigated Pt and RuO₂as a bottom electrode for a device application of PZT thin film. The bottom electrodes were prepared by using an RF magnetron sputtering method. We studied some of the property influencing factors such as substrate temperature, gas flow ratem and RF power. An oxygen partial pressure from 0 to 50% was investigated. The results show that only Ru metal was grown without supplying any O₂gas. Both Ru and RuO₂phases were formed for O₂partial pressure between 10-40%. A pure RuO₂phasewas obtained with O₂partial pressure of 50%. A substrate temperature from room temperature to 400°C was investigated with XRD for the film crystallinity examination. The substrate temperature influenced the surface morphology and the resistivity of Pt and RuO₂ as well as the film crystal structure. From the various considerations, we recommend the substrate temperature of 300°C for the bottom electrode growth. Because PZT film growth on top of bottom electrode requires a temperature process higher than 500°C, bottom electrode properties were investigated as a functiona of post anneal temperature. As post anneal temperature was increasedm the resistibity of Pt and RuO₂was decreased. However, almost no change was observed in resistibity for an anneal temperature higher than 700°C . From the studies on resistivity and surface morphology, we recommend a post anneal temperature less than 600°C.
Young‑Gil Jung,Wonseok Yang,Jae Ik Hyun,Shae K. Kim,Hyunkyu Lim,Do Hyang Kim 대한금속·재료학회 2021 METALS AND MATERIALS International Vol.27 No.12
Three alloys (Mg–6Zn–1.2Y, Alloy I; Mg–3.65Zn–1.65Y, Alloy II; and Mg–4.3Zn–1.4Y, Alloy III) with same volume fractionand grain size were designed to evaluate the effects of the I-phase (Mg3Zn6Y) and W-phase (Mg3Zn3Y2), which are themajor phases in Mg–Zn–Y alloys, on the mechanical properties. The tensile strength of Alloy I with the I-phase at roomtemperature was the highest among the tested alloys because the coherent interface between the I-phase and the α-Mg phasewas more resistant to cracking than the incoherent interface between the W-phase and the α-Mg phase. A cross-sectionalmicrostructure analysis of a sample that was tensile-tested at 423 K revealed that the morphology of the I-phase remainedrelatively stable. In contrast, the W-phase was broken and fragmented during the tensile test at 423 K because it had higherbrittleness under the test conditions. Therefore, the tensile and creep properties of Alloy I at 423 K were better than thoseof Alloys II and III containing the W-phase. According to the results, the I-phase in the Mg-Zn-Y alloy was more beneficialto the mechanical properties at room temperature and 423 K than the W-phase.
임영식,이홍재,이도진,허종수,손보균,조주식 한국환경과학회 2002 한국환경과학회지 Vol.11 No.12
This study was carried out to evaluate the pollutant removal efficiencies of the advanced drinking water treatment using ozonation process. For raw water, Nakdong River was used. By conducting batch test of ozonation efficiencies of the ozonation were 94 to 92%, respectively. Removal efficiencies of single VOC compound or mixed VOC compounds in the raw water were 80% to 90% by the ozonation with 2 mg/ℓ dosage and 10 minutes contact time. Removal efficiencies of ABS by the ozonation with 1 mg/ℓ, 3 mg/ℓ dosage and 20 minutes contact time were 83% to 96%, respectively. Almost 67% of chlorophyll-a at the concentration of 38.㎍/ℓ was removed by ozonation at ozone dosage of 1mg/ℓ for 20 min. considering the efficiency of ozone utilization and water treatment, the most effective ozonation could be obtained with high ozone dosage and short and short contact time.