RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
        • 등재정보
        • 학술지명
        • 주제분류
        • 발행연도
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        자동렌즈미터를 이용한 소프트 콘택트렌즈의 굴절력 측정 방법에 관한 신뢰도

        김건규,이욱진,이선행,곽호원,유동식 한국안광학회 2010 한국안광학회지 Vol.15 No.1

        Purpose: To assess the reliability for measuring the back vertex power of soft contact lenses by dry blotting and wet cell method using an auto-lensmeter. Methods: The soft contact lenses used for measurement were 5 types that were distributed in Korea, and 4 back vertex powers (-1.50D, -3.00D, -6.00D, -9.00D) were used, and repeatability and reproducibility were evaluated by measuring them with an auto-lensmeter by two examiners. Results: Measured powers by dry blotting method were ranged in mean differences from 0.03D to 0.18D for overall lenses, 0.10D to 0.18D for silicone hydrogel lenses, 0.03D to 0.08D for hydrogel lenses. The mean differences between two examiners were less than 0.10D, and the inter-examiner reproducibility was good for dry blotting method. The mean difference between powers determined by wet cell method were 0.09D to 0.69D, the mean differences between two examiners were 0.02D to 0.59D. The reliability of measurements and inter-examiner reproducibility were less than dry blotting method. Conclusions: The reliability of measurements for all materials was better in dry blotting than wet cell method, the reliability of measurements for silicone hydrogel lenses was low in both methods. In clinical practical which requires quick checking of back vertex power using an auto-lensmeter, dry blotting method is thought to be more efficient than wet cell one. 목적: 자동렌즈미터를 이용한 소프트 콘택트렌즈의 굴절력 측정에서 dry blotting과 wet cell 방법에 따른 신뢰도 를 평가하고자 하였다. 방법: 측정에 사용한 소프트렌즈는 현재 국내에서 유통되고 있는 렌즈 5종류, 4개의 굴절력 (-1.50D, -3.00D, -6.00D, -9.00D)을 이용하였고, 두 검사자가 자동렌즈미터로 측정하여 반복성과 재현성을 평가하 였다. 결과: Dry blotting방법으로 측정한 굴절력의 평균 차이는 0.03~0.18D였으며, 실리콘 하이드로겔 렌즈에서 0.10~0.18D, 하이드로겔 렌즈에서 0.03~0.08D로 나타났다. 두 검사 간의 평균 차이는 0.10D이하로 측정자 간의 재 현성이 좋은 것으로 나타났다. Wet cell방법으로 측정한 굴절력의 평균 차이는 0.09~0.69D였으며, 두 검사자 간에 평균 차이는 0.02~0.59D로 나타났으며, 소재에 따른 측정의 신뢰도와 검사자 간의 재현성은 낮았다. 결론: 모든 재 질에 대해 dry blotting 방법이 wet cell방법보다 신뢰도가 좋았으며, 두 방법 모두 실리콘 하이드로겔 렌즈에서는 낮 은 신뢰도를 보였다. 자동렌즈미터를 이용하여 신속히 후면 정점굴절력을 확인할 필요가 있는 실무 현장에서 dry blotting방법이 효율적인 것으로 판단된다.

      • KCI등재

        MYSTERY CIRCLE 시스템을 이용한 폭주부족형 사위및 간헐성 사시 환자의 시기능 훈련 효과 연구

        이창선,김건규,전영기,김종기,최철희,김기홍 한국안광학회 2010 한국안광학회지 Vol.15 No.4

        목적: 이 연구의 목적은 MYSTERY CIRCLE 시스템을 이용하여 폭주부족 사위와 간헐성 사시 환자의 시기능 훈 련효과를 조사하였다. 방법: 시기능 훈련 대상자는 안질환과 조절이상 및 수직사위가 없는 폭주부족 사위(n=18)와 간헐성 사시(n=8) 이상자 26명을 대상으로 추적 관찰하였고, 훈련기간은 8주간 매주 한번은 안경원에 방문하여 시 기능 훈련에 따른 변화를 측정하였다. 결과: MYSTERY CIRCLE 시스템으로 시기능 훈련을 실행한 결과 기능적 및 감각적 증상이 개선되었다. 그리고 Worth 4 Dot검사, 입체시 검사 및 적색렌즈 융합 속도 검사도 개선을 보여 주었 다. 결론: MISTERY CIRCLE 시기능 훈련 시스템을 이용한 시기능 훈련은 좋은 양안시 이상 개선 효과를 보여주 었다. Purpose: The purpose of this study was to investigate the effect of vision training using MYSTERY CIRCLE system on patients with exophoria and intermittent extropia. Mehtods: The vision training observation group consists of 26 clients who had exophoria (n=18) and intermittent extropia (n=8) without opthalmic diseases or vertical phoria. Our clients took each vision training once a week for eight weeks and were investigated for the symptoms changes of binocular vision. Results: According to the results, MISTERY CIRCLE vision training methods improved the binocular vision function and sensation symptoms. For Worth 4 Dot test, Titmus test and red lenses showed fusion rate changes. Conclusions: The study proved that MISTERY CIRCLE vision training system for patients with binocular vision was effective for the improvement of the binocular vision symptoms of these patients.

      • KCI등재

        푸시 및 공유 : 모바일 콘텐츠 기반 네트워크에서 선행적 콘텐츠 전송의 모델링

        왕효비,김건규,권태경,최양희 한국정보과학회 2012 정보과학회논문지 : 정보통신 Vol.39 No.4

        셀룰러 네트워크 운영자들은 셀룰러 링크 용량을 초과하는 트래픽 요청을 모바일 사용자들로부터 받는 것에 대해 심각하게 고려한다. 하지만 기존의 pull-based communication model 은 이러한 데이터 급증 문제를 다루는 것에 적당하지 않다. 그래서 이러한 문제점을 해결하기 위해 선행적으로 데이터를 push-based(푸시) 전송하는 모델을 제안한다. 또한, 셀룰러 링크에서의 트래픽 로드를 줄이기 위해 모바일 사용자들 간의 직접 연결(e.g. Wi-Fi)을 사용하는 방식을 사용하고자 한다. Ad hoc 연결에서의 직접적인 share-based(공유) 전달 방식과 함께 셀룰러 링크에서의 push-based 전달 방식이 데이터를 얼마나 빨리 퍼뜨리는지 분석해 본다. 마지막으로, 이에 대한 최적화 프레임워크를 구현해보고, 분산 비용, 전달시간, 분산 비율 간의 트레이드 오프를 탐색·평가하여 분할 알고리즘을 설계해 본다. Cellular network operators are seriously concerned with the ever increasing traffic demand from mobile users, which is overwhelming the wireless link capacity. The conventional pull-based communication model is not appropriate to deal with the data explosion problem. Instead, we propose to push the contents proactively. Also, we leverage the direct connectivity (e.g. Wi-Fi) among mobile users to reduce the traffic load on cellular links for content delivery. We analyze how fast content is disseminated by the push-based delivery via cellular links along with direct share-based delivery via ad hoc connectivity among users. We also formulate the optimization framework and design a split algorithm by which the tradeoff among dissemination cost, delivery delay, and dissemination portion is explored and evaluated.

      • KCI등재

        국내 지진동 특성에 대한 기기 용접 정착부의 비탄성에너지 흡수계수를 고려한 지진취약도 평가

        임승현,김건규,최인길,곽신영 한국지진공학회 2023 한국지진공학회논문집 Vol.27 No.1

        In Korea, most nuclear power plants were designed based on the design response spectrum of Regulatory Guide 1.60 of the NRC. However, in the case of earthquakes occurring in the country, the characteristics of seismic motions in Korea and the design response spectrum differed. The seismic motion in Korea had a higher spectral acceleration in the high-frequency range compared to the design response spectrum. The seismic capacity may be reduced when evaluating the seismic performance of the equipment with high-frequency earthquakes compared with what is evaluated by the design response spectrum for the equipment with a high natural frequency. Therefore, EPRI proposed the inelastic energy absorption factor for the equipment anchorage. In this study, the seismic performance of welding anchorage was evaluated by considering domestic seismic characteristics and EPRI's inelastic energy absorption factor. In order to reflect the characteristics of domestic earthquakes, the uniform hazard response spectrum (UHRS) of Uljin was used. Moreover, the seismic performance of the equipment was evaluated with a design response spectrum of R.G.1.60 and a uniform hazard response spectrum (UHRS) as seismic inputs. As a result, it was confirmed that the seismic performance of the weld anchorage could be increased when the inelastic energy absorption factor is used. Also, a comparative analysis was performed on the seismic capacity of the anchorage of equipment by the welding and the extended bolt.

      • KCI등재

        지진하중 및 임의의 하중을 받는 배관 시스템에 대한 응답을 추정하기 위한 데이터 기반 디지털 트윈

        김동창,김건규,곽신영,임승현 한국지진공학회 2023 한국지진공학회논문집 Vol.27 No.6

        The importance of Structural Health Monitoring (SHM) in the industry is increasing due to various loads, such as earthquakes and wind, having a significant impact on the performance of structures and equipment. Estimating responses is crucial for the effective health management of these assets. However, using numerous sensors in facilities and equipment for response estimation causes economic challenges. Additionally, it could require a response from locations where sensors cannot be attached. Digital twin technology has garnered significant attention in the industry to address these challenges. This paper constructs a digital twin system utilizing the Long Short-Term Memory (LSTM) model to estimate responses in a pipe system under simultaneous seismic load and arbitrary loads. The performance of the data-driven digital twin system was verified through a comparative analysis of experimental data, demonstrating that the constructed digital twin system successfully estimated the responses.

      • KCI등재

        색 시표와 색 필터를 이용한 새로운 사위검사의 신뢰도

        이선행,박선영,김상엽,이동열,김건규,조현국,손정식,이재윤 한국안광학회 2010 한국안광학회지 Vol.15 No.3

        목적: 새로운 적청사위시표(Red-Blue phoria chart; RBP) 검사의 신뢰성을 평가하였다. 방법: 38명을 대상으로 원 거리(5m), 근거리(40cm) 사위량을 측정하였다. RBP 시표 사위검사, 하웰시표 사위검사(HP), 그리고 Muscle Imbalance Measure (MIM) 시표 사위검사를 실시하고 검사에 대한 신뢰도를 서로 비교하였다. 결과: 수평 사위도는 원거리 RBP -0.600.727D, HP -0.871.051D, MIM -1.501.346D, 근거리 RBP -2.572.352D, HP -2.802.411D, MIM -3.842.603D로 측정되었다. 검사 신뢰도는 원거리의 경우 RBP>MIM>HP 순이었고, 근거리의 경우 MIM>RBP>HP 순으로 나타났다. 결론: RBP 검사법은 신뢰도가 높은 사위검사법으로 판명되었다. Purpose: The repeatability of a new Red-Blue phoria chart test (Red-Blue phoria chart; RBP) was appreciated. Methods: Distance (5 m) and near (40 cm) heterophoria was measured in 38 visually normal subjects. Phoria tests using RBP, Howell phoria card (HP), and MIM card (MIM) were done and the repeatability of each phoria test was compared with one another. Results: The mean of horizontal deviations was that RBP was -0.602 0.727D, HP was -0.8651.051D, and MIM was -1.5011.346D" at distance, and that RBP was -2.5662.352D, HP was -2.8042.411D, MIM was -3.8382.603D" at near. The repeatability was RBP>MIM>HP in distance tests and MIM>RBP>HP in near tests. Conclusions: RBP test is identified as a reliable phoria test having high repeatability.

      • KCI등재

        토릭소프트콘택트렌즈의 착용 후 축 정렬 상태의 변화 분석

        김상엽,이동열,이선행,김건규,송섭,조현국 한국안광학회 2010 한국안광학회지 Vol.15 No.3

        Purpose: To emphasize the necessity of post-fitting by follow-up test, the mis-alignment was analyzed after initial wearing of toric soft contact lenses (TSCL). Methods: After trial contact lenses were worn to 87 eyes with myopic astigmatism for 1 week, we observed the alignment of axis mark on trial contact lenses using slit lamp and corrected the rotated axis by method of LARS. After final fitting, rotation ratio, rotation degree and rotation position were analyzed compared to initial prescription divided to amount of cylinderical and spherical powers. Results: Rotation ratio of TSCL's axis was increased as increment of both cylinderical powers and (-)spherical powers. An average of rotation degree was 10o~13o which was not related to amount of their powers. Rotation position of TSCL's axis was more to temporal than to nasal. Conclusions: Because mis-alignment of axis after TSCL wearing induce the poor sight, adjustment of axial alignment as a result of follow-up must be performed. 목적: 토릭소프트콘택트렌즈(TSCL) 최초 착용 후 발생한 축의 정렬상태 변화를 분석하여 추적검사에 의한 피팅 의 필요성을 강조하고자 하였다. 방법: 근시성 난시 87안을 대상으로 시험콘택트렌즈를 1주일 간 착용시킨 후, 틈새 등현미경을 이용하여 시험렌즈에 표시된 축 표시의 정렬상태를 관찰하여 회전된 축을 LARS법에 따라 교정하였다. 최종 교정 후 축 정렬상태를 최초 처방값과 비교하여 변화된 축의 회전율, 회전 각도, 그리고 회전방향을 처방 렌 즈의 원주굴절도와 구면굴절도에 따라 나누어 분석하였다. 결과: 원주굴절력이 클수록, (-)구면굴절력이 클수록 TSCL의 축 회전율은 높았으나 회전 각도는 평균 10o~13o로 굴절력 정도에 따른 차이가 없었다. 그리고 축 회전방 향은 코쪽보다 귀쪽으로 회전한 비율이 더 높았다 결론: TSCL 착용 후 축 회전은 시력저하를 유발하므로 반드시 추적검사 결과에 따라 축 정렬 조정을 실시하여야 한다.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼