http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
변연골 흡수가 내측연결 임플란트 매식체의 응력분포에 미치는 영향
윤미정,윤민철,엄태관,허중보,정창모 대한치과보철학회 2012 대한치과보철학회지 Vol.50 No.2
Purpose: The change of the marginal bone around dental implants have significance not only for the functional maintenance but also for the esthetic success of the implant. The purpose of this study was to investigate the load transfer of internal conical joint type implant according to marginal bone resorption by using the three-dimensional finite element analysis model. Materials and methods: The internal conical joint type system was selected as an experimental model. Finite element models of bone/implant/prosthesis complex were constructed. A load of 300 N was applied vertically beside 3 mm of implant axis. Results: The pattern of stress distribution according to marginal bone resorption was similar. The maximum equivalent stress of implant was increase according to marginal bone resorption and the largest maximum equivalent stress was shown at model of 1 mm marginal bone resorption. Although marginal bone loss more than 1mm was occurred increasing of stress, the width of the stress increase was decreasing. Conclusion: According to these results, the exposure of thin neck portion of internal conical joint type implant is most important factor in stress increasing. 연구 목적: 지금까지 성공적인 임플란트 치료를 위해 많은 연구가 진행되어 왔으며, 임플란트 주변 골 흡수 현상에 대한 연구는 매우 관심이 높은 분야 중 하나이다. 이에 본 연구에서는 삼차원 유한요소응력분석을 이용하여 변연골 흡수가 내측연결 임플란트 매식체의 기계적 안정성에 미치는 영향을 간접적으로 확인하고자 하였다. 연구 재료 및 방법: 악골에 식립된 내측연결 형태의 임플란트 매식체에 티타늄 소재의 임플란트 지대주를 지대주 나사로 연결하고 상부에 금합금관을 장착하는 삼차원 유한요소모형을 설계하였다. 0, 1, 2, 3 mm의 변연골 흡수 상태를 적용하고, 교합면 중심에서부터 3 mm 편측에 300 N의 수직 하중을 가하여 임플란트 매식체에 발생하는 최대 주응력을 계산하였다. 결과: 유한요소분석결과 변연골 흡수에 따른 임플란트 매식체의 최대 주응력 분포는 유사한 양상을 보였으며, 임플란트 매식체 상단에서 가장 높은 응력 집중이 나타났다. 최대 주응력은 처음 1 mm 변연골 흡수를 가정하였을 때 가장 크게 증가하였고, 이후 변연골 흡수가 증가할수록 응력은 증가하였지만 응력 증가의 폭은 감소하는 경향을 보였다. 결론: 이러한 결과로부터 내측연결 임플란트에서 매식체 두께가 얇은 경부의 노출은 변연골 흡수로 인한 응력 증가에 가장 큰 원인임을 알 수 있었으며, 매식체의 변형, 균열 및 파절 등의 기계적 실패를 감소시키기 위해서는 이에 대한 외과적, 보철적 고려가 필요할 것으로 생각된다.
수산화인회석 코팅 임프란트의 골치유과정에 관한 실험적 연구
엄태관(Tae-Gwan Eom),김종화(Jong-Hwa Kim),조인희(In-Hee Cho),정창모(Chang-Mo Jeong),조용석(Yong-Seok Cho),김영균(Young-Kyun Kim) 대한구강악안면외과학회 2011 대한구강악안면외과학회지 Vol.37 No.4
Introduction: Hydroxyapatite(HA) coating implant can accelerate osseointegration, however, there are many controversies. Materials and Methods: This study examined the early osseointegration of two types of hydroxyapatite coated implants. Twelve adult male miniature pigs (Medi Kinetics Micropigs, Medi Kinetics Co., Ltd., Busan, Korea) were used in this study. In the implants placed in the mandible, a histomorphometric evaluation was performed to evaluate the bone-implant contact (BIC) ratio. Results: The BIC ratio increased with time. TS III HA and Zimmer HA were not significantly different (P>0.05). At 8 weeks, the BIC of Zimmer HA was higher than TS III HA, but there was no significant difference (P>0.05). Conclusion: HA coated implants will accelerate early osseointegration.
대한간학회지 제8차 춘계학술대회 초록집 : 구연 ; B형, C형 간염 바이러스에 중복 감염된 만성 간염 환자의 치료
한태호 ( Han Tae Ho ),박상훈 ( Park Sang Hun ),계세협 ( Gye Se Hyeob ),김동준 ( Kim Dong Jun ),이명석 ( Lee Myeong Seog ),엄순호 ( Eom Sun Ho ),변관수 ( Byeon Gwan Su ),김학철 ( Kim Hag Cheol ),박충기 ( Park Chung Gi ),유재영 ( Yu 대한간학회 2002 Clinical and Molecular Hepatology(대한간학회지) Vol.8 No.2(S)
Lee, Sang-Gwan,Hoh, Woo-Pil,Eom, Ki-Dong,Lee, Keun-Woo,Oh, Tae-Ho The Korean Society of Veterinary Science 2006 大韓獸醫學會誌 Vol.46 No.1
About 8 year-old castrated male Yorkshire terrier was presented for evaluation of dysuria, stranguria, hemtauria, and pollakiuria. On history taking, dysuria first was observed three months ago and these signs were waxed and waned. Physical examination revealed mild left perineal swelling. On routine laboratory examination, no significant findings were identified. Positive contrast urogram identified peritoneal herniation of urinary bladder. Urinalysis showed proteinuria and hematuria. Urine sediment revealed epithelial cells, white blood cells and rod-shaped bacteria. Pseudomonas aeroginosa was isolated from urine obtained through cystocentesis, and had resistance against fourteen antibiotics. Cystitis caused by P. aeruginosa concurrent with cystolithiasis and perineal hernia was diagnosed. Cystotomy, herniorrhaphy and EDTA-Tris solution lavage of bladder were performed. The patient was recovered to normal condition 2 days after treatment. Two weeks later, bacterial culture of urine was negative and any abnormality in ultrasonogram and urinalysis was not observed except calcium oxalate dihydrate crystals.
MEMS 스위치 기반 재구성 고출력 증폭기를 갖는 재구성 능동 배열 안테나 시스템
명성식(Seong-Sik Myoung),엄순영(Soon Young Eom),전순익(Soon-Ik Jeon),육종관(Jong-Gwan Yook),Terence Wu,임규태(Kyu-Tae Lim),Joy Laskar 한국전자파학회 2010 한국전자파학회논문지 Vol.21 No.4
본 논문에서는 상용 초고주파 MEMS 스위치를 이용하여 세 개의 주파수 대역에서 재구성 동작이 가능한 주파수 재구성 능동 배열 안테나 시스템(Reconfigurable Active Array Antenna System: RAA System)을 제안하였다. MEMS 스위치는 삽입 손실 및 선형성 특성이 우수하고 격리도가 높아 주파수 재구성 시스템 구현 시, 재구성을 위한 스위치로 인한 성능 열화가 거의 없다는 장점이 있다. 제안된 주파수 재구성 능동 배열 안테나 시스템은 간단한 구조의 임피던스 매칭 회로(Reconfigurable impedance Matching Circuit: RMC)를 갖는 주파수 재구성 증폭기(Reconfigurable Front-end Amplifier: RFA)가 집적화 되어 있으며, 안테나 방사체(Reconfigurable Antenna Element: RAE)와 재구성 제어 보드(Reconfiguration Control Board: RCB)로 구성되어 있다. 본 논문에서 제안한 RAA 시스템은 850 ㎒, 1.9 ㎓, 3.4 ㎓의 세 개 주파수로 재구성되어 동작하며, 안테나 방사체는 2×2 배열을 가지고 각각의 방사체는 광대역 다이폴 형태를 갖는다. 제작된 RAA 시스템은 실험을 통하여 그 타당성을 확인하였다. In this paper, a novel frequency reconfigurable active array antenna(RAA) system, which can be reconfigurable for three reconfigurable frequency bands, is proposed by using commercial RF MEMS switches. The MEMS switch shows excellent insertion loss, linearity, as well as isolation. So, the system performance degradation of the reconfigurable system by using MEMS switches can be minimized. The proposed frequency reconfigurable active antenna system is consisted with the noble frequency reconfigurable front-end amplifiers(RFA) with the simple reconfigurable impedancematching circuits(RMC), reconfigurable antenna elements(RAE), as well as a reconfiguration control board(RCB) for MEMS switch control. The proposed RAA system can be reconfigurable for three frequency bands, 850 ㎒, 1.9 ㎓, and 3.4 ㎓, with 2×2 array of the RAE having broadband printed dipole antenna topology. The validity of the proposed RFA as well as RAA is also presented with the experimental results of the fabricated systems.
임플란트 지대주나사의 조임회전력이 연결부 안정성에 미치는 영향에 관한 3차원 유한요소해석 연구
엄태관,서승우,전계록,신정욱,정창모,Eom, Tae-Gwan,Suh, Seung-Woo,Jeon, Gyeo-Rok,Shin, Jung-Wook,Jeong, Chang-Mo 대한치과보철학회 2009 대한치과보철학회지 Vol.47 No.2
Statement of problem: Loosening or fracture of the abutment screw is one of the common problems related to the dental implant. Generally, in order to make the screw joint stable, the preload generated by tightening torque needs to be increased within the elastic limit of the screw. However, additional tensile forces can produce the plastic deformation of abutment screw when functional loads are superimposed on preload stresses, and they can elicit loosening or fracture of the abutment screw. Therefore, it is necessary to find the optimum tightening torque that maximizes a fatigue life and simultaneously offer a reasonable degree of protection against loosening. Purpose: The purpose of this study was to present the influence of tightening torque on the implant-abutment screw joint stability with the 3 dimensional finite element analysis. Material and methods: In this study, the finite element model of the implant system with external butt joint connection was designed and verified by comparison with additional theoretical and experimental results. Four different amount of tightening torques(10, 20, 30 and 40 Ncm) and the external loading(250 N, $30^{\circ}$) were applied to the model, and the equivalent stress distributions and the gap distances were calculated according to each tightening torque and the result was analyzed. Results: Within the limitation of this study, the following results were drawn; 1) There was the proportional relation between the tightening torque and the preload. 2) In case of applying only the tightening torque, the maximum stress was found at the screw neck. 3) The maximum stress was also shown at the screw neck under the external loading condition. However in case of applying 10 Ncm tightening torque, it was found at the undersurface of the screw head. 4) The joint opening was observed under the external loading in case of applying 10 Ncm and 20 Ncm of tightening torque. 5) When the tightening torque was applied at 40 Ncm, under the external loading the maximum stress exceeded the allowable stress value of the titanium alloy. Conclusion: Implant abutment screw must have a proper tightening torque that will be able to maintain joint stability of fixture and abutment. 연구목적: 임플란트 치료에서 흔히 발생하는 기계적인 문제점을 하나가 지대주나사의 풀림과 파절이다. 일반적으로 나사 연결의 안정성을 위해서는 지대주나사의 조임회전력에 의한 전하중을 나사의 탄성한계까지 증가시킬 필요가 있다. 그러나 저작운동에 의한 기능부하는 전하중이 가해진 지대주나사에 추가적인 인장력을 가하게 되어 나사의 풀림이나 파절의 가능성을 높인다. 이러한 풀림이나 파절을 방지하면서 동시에 최대의 결합 강도를 가지는 조임회전력을 찾는 연구가 필요하다. 본 연구는 지대주나사의 조임회전력이 임플란트-지대주 연결부 안정성에 미치는 영향을 3차원 유한요소 분석을 통하여 확인하고자했다. 연구 재료 및 방법: External butt joint를 가진 임플란트를 기반으로 3차원 유한요소 해석모형을 설계하였다. 조임회전력에 따른 지대주나사의 전하중을 이론치, 실험치 및 해석치를 비교하여 해석모형을 검증하였다. 검증한 해석모형에서 대해 조임회전력을 10 Ncm, 20 Ncm, 30 Ncm, 그리고 40 Ncm로 각각 적용하고 지대주에 30도 경사지게 250 N의 외부하중을 가하여 유산요소 해석을 실시하였다. 그 결과를 통해 지대주나사의 최대 등가응력을 계산하고 고정체와 지대주 연결부의 응력분포 및 이개거리(gap distance)를 산출하였다. 결과 및 결론: 본 연구조건 하에서 다음과 같은 결과를 얻었다. 1. 전하중은 조임회전력이 클수록 증가하였다. 2. 조임회전력 적용 후 최대 등가응력은 지대주나사 경부에서 발생하였으며, 나사산 체결부에서는 주로 경부쪽 네 개의 나사산에 응력이 집중되었다. 3. 외부하중을 가했을 때에도 조임회전력을 적용했을 때와 동일하게 최대 등가응력은 주로 지대주나사 경부에서 발생하였으나, 10 Ncm의 조임회전력을 적용한 경우에서는 지대주나사 두부밑면에서 발생하였다. 4. 외부하중을 가했을 때 10 Ncm와 20 Ncm의 조임회전력을 적용한 경우에서는 연결부 이개(joint opening) 현상이 관찰 되었다. 5. 조임회전력이 40 Ncm인 경우에는 경사하중에 의해 지대주나사의 경부에 발생하는 최대등가응력이 나사의 소재인 티타늄 합금의 허용응력을 초과하였다. 이상의 결과로 볼 때, 조임회전력은 고정체와 지대주 연결부의 안정성에 영향을 미치는 것이 확인되었다. 임플란트 지대주나사는 임상에서 발생하는 기능 하중을 고려하여 고정체와 지대주 연결의 안정성을 유지할 수 있는 적정 조임회전력의 크기가 제안되어야 한다.