극초단 펄스 레이저를 사용한 유리 내부의 필라멘테이션에 대한 실험적 연구
최원석,윤지욱,김주한,최지연,장원석,김재구,최두선,황경현,조성학,Choi, Won-Suk,Yoon, Ji-Wook,Kim, Joohan,Choi, Jiyeon,Chang, Won-Seok,Kim, Jae-Goo,Choi, Doo-Sun,Whang, Kyoung Hyun,Cho, Sung-Hak 한국레이저가공학회 2013 한국레이저가공학회지 Vol.16 No.1
We have successfully formed filament inside of a transparent soda-lime glass using a Ti:sapphire based femtosecond laser. To make filament form, keeping the laser intensity higher than critical intensity is essential. Also each of the machining parameters plays an important role for the formation of filament. In this paper, we study what parameter can possibly influence for formation of filament, and we introduce an application using filamentation by femtosecond laser for transparent material.
AMOLED 제조공정에 사용되는 Fine Metal Mask 용 얇은 Invar 합금의 진동자를 이용한 펨토초 레이저 응용 홀 드릴링
최원석,김훈영,신영관,최준하,장원석,김재구,조성학,최두선,Choi, Won-Suk,Kim, Hoon-Young,Shin, Young-Gwan,Choi, Jun-ha,Chang, Won-Seok,Kim, Jae-Gu,Cho, Sung-Hak,Choi, Doo-Sun 한국금형공학회 2020 한국금형공학회지 Vol.14 No.3
One of display trends today is development of high pixel density. To get high PPI, a small size of pixel must be developed. RGB pixel is arranged by evaporation process which determines pixel size. Normally, a fine metal mask (FMM; Invar alloy) has been used for evaporation process and it has advantages such as good strength, and low thermal expansion coefficient at low temperature. A FMM has been manufactured by chemical etching which has limitation to controlling the pattern shape and size. One of alternative method for patterning FMM is laser micromachining. Femtosecond laser is normally considered to improve those disadvantages for laser micromachining process due to such short pulse duration. In this paper, a femtosecond laser drilling for thickness of 16 ㎛ FMM is examined. Additionally, we introduce experimental results for controlling taper angle of hole by vibration module adapted in laser system. We used Ti:Sapphire based femtosecond laser with attenuating optics, co-axial illumination, vision system, 3-axis linear stage and vibration module. By controlling vibration amplitude, entrance and exit diameters are controllable. Using vibrating objective lens, we can control taper angle when femtosecond laser hole drilling by moving focusing point. The larger amplitude of vibration we control, the smaller taper angle will be carried out.
Sensitiv Imago<sup>TM</sup> 측정에 의한 야뇨증 환아의 검사 결과 보고
최원석,김덕곤,이진용,Choi, Won Seok,Kim, Deog Gon,Lee, Jin Yong 대한한방소아과학회 2014 대한한방소아과학회지 Vol.28 No.4
Objectives The purpose of this study is to report the nocturnal enuresis in children using Sensitiv $Imago^{TM}$. Methods Twenty nocturnal enuresis children were tested using Sensitiv $Imago^{TM}$. Results 10 cases showed the lowest score at filter $#5^*$ and 7 cases showed the lowest score at filter $6^*$ in {Express Monitoring} of {Review of System Disorders of Homeostasis}. Conclusions Further study with more samples is necessary to establish the accuracy of Sensitiv $Imago^{TM}$.
치주질환으로 인한 전치부 정출(Extrusion)의 심미적 수복에 관한 증례
최원석,Choi, Won-Seok 대한심미치과학회 1999 Journal of the Korean Academy of Esthetic Dentistr Vol.8 No.1
Dental clinicians commonly encounter extrusion of the anterior teeth due to localized alveolar bone loss in adult patients with chronic periodontitis. This pathologic migration of the anterior not only may cause loss of functional anterior guidance and continuous periodontal destruction, but also can lead to esthetic disaster. In fact, most frequently reported chief complaint of the patients with extruded anterior teeth is the 'loss of esthetics', not the periodontal problem itself. The utilization of the expertise and skills in the various dental disciplines is thought to be the best treatment modality for the ultimate functional and esthetic attainment. Interdisciplinary therapy, involving periodontics, orthodontics, and restorative dentistry, was performed for the highest levels of patient and provider satisfaction in this case.
LC 공진형 압력 센서를 이용한 돼지 경골 동맥의 실시간 혈압 측정
최원석,김진태,정연호,Choi, Won-Seok,Kim, Jin-Tae,Joung, Yeun-Ho 한국전기전자재료학회 2012 전기전자재료학회논문지 Vol.25 No.6
We have developed an implantable wireless sensor for real time pressure monitoring of blood circulation system. MEMS (micro-electro-mechanical system) technology was adopted as a sensor development method. The sensor is composed of photolithographically patterned inductors and a distributed capacitor in gap between the inductors. A resulting LC resonant system produces its resonant frequency in range of 269 to 284 MHz at 740 mmHg. To read the resonant frequency changed by blood pressure variation, we developed a custom readout system based on a network analyzer functionality. The bench-top testing of the pressure sensors showed good mechanical and electrical functionality. A sensor was implanted into tibial artery of farm pig, and interrogated wirelessly with accurate readings of blood pressure. After 45 days, the sensor's electrical response and histopathology were studied with good frequency reading and biocompatibility.
최원석,신영주,김하경,이가영,Won Seok Choi,MD,Young Joo Shin,MD,PhD,Ha Kyoung Kim,MD,PhD,Kayoung Yi,MD,PhD 대한안과학회 2013 대한안과학회지 Vol.54 No.12
Purpose: In the present study we compared the intraocular pressure (IOP) after cataract surgery according to incisional techniques. <br /> Methods: Patients who underwent phacoemulsification with intraocular lens implantation were divided into 2 groups: clear corneal incision group (CC group), and scleral tunnel incision group (ST group). All complicated cases were excluded. IOP was measured preoperatively and at 1 week, 1, 3, 6, 12, 18 and 24 months after surgery.<br /> Results: Seventy-seven patients (100 eyes) were enrolled in the present study; CC group (28 patients, 33 eyes), ST group (49 patients 67 eyes). Preoperative IOPs in both groups were not significantly different (p = 0.908, student’s t-test). IOP in the CC group at 1 week after surgery significantly decreased 2.22 ± 2.57 mm Hg compared to preoperative IOP (p < 0.001, repeated-measures ANOVA with post hoc analysis), and the IOP of the ST group decreased 2.11 ± 2.50 mm Hg (p < 0.001, repeated-measures ANOVA with post hoc analysis). The lowered IOP was maintained for 24 months postoperatively. There was no significant difference in IOP change after surgery depending on incisional techniques (p = 0.848, repeated measures ANOVA).<br /> Conclusions: There may be no difference in IOP lowering effect after surgery depending on incisional techniques. <br /> J Korean Ophthalmol Soc 2013;54(12):1856-1861
최원석,이난희,최웅규,Choi, Won-Seok,Lee, Nan-Hee,Choi, Ung-Kyu 한국식품영양학회 2019 韓國食品營養學會誌 Vol.32 No.5
In this study, the quality characteristics of 30 kinds of long-term matured soy sauce collected from all over Korea classified according to ripening period were analyzed. The longer the soy sauce had to matured, the closer the pH was to neutrality. Acidity decreased as the ripening period increased. Total nitrogen and amino nitrogen content increased as the soy sauce matured. Moisture content decreased with the increasing soy sauce ripening period, and the content of pure extracts increased in proportion to the ripening period. The numbers of bacteria, fungi, and yeast increased in proportion to the maturation period. The content of P was highest in all soy sauce analyzed, followed by K, Ca, Mg, Fe and Zn. Mg and Ca contents decreased with maturing, whereas K increased with maturing.
쌀밥의 조직감에 대한 기기적 측정값과 관능적 측정값의 상관관계 연구
최원석,Choi, Won-Seok 한국식품영양학회 2016 韓國食品營養學會誌 Vol.29 No.5
This study aimed to find the optimum instrumental test conditions for the Texture Profile Analysis (TPA) of cooked rice in order to predict the sensory texture attributes (hardness, adhesiveness, chewiness). Sensory evaluation was performed for three kinds of instant cooked rice with university students in their twenties and the results of the sensory evaluation were compared to instrumental TPA patterns. Using partial least squares regression, the instrumental TPA results at a cross-head speed of 1.0 mm/sec and a compression ratio of 70% proved to be an excellent predictor of the sensory attributes of hardness ($R^2=0.99$) and chewiness ($R^2=0.99$). The results at a cross-head speed of 0.5 mm/sec and compression ratio of 30% provided an excellent model for the prediction of sensory adhesiveness ($R^2=0.83$). In this experimental range, sensory hardness and chewiness showed a high correlation with instrumental TPA parameters (hardness, cohesiveness, adhesiveness, springiness, chewiness) with a high cross-head speed and compression ratio, while sensory adhesiveness showed a high correlation with the TPA parameters with a low cross-head speed and compression ratio.
PECVD로 합성한 다이아몬드상 카본박막의 전기적 특성
최원석,박문기,홍병유,Choi, Won-Seok,Park, Mun-Gi,Hong, Byung-You 한국전기전자재료학회 2008 전기전자재료학회논문지 Vol.21 No.11
In addition to its similarity to genuine diamond film, diamond-like carbon (DLC) film has many advantages, including its wide band gap and variable refractive index. In this study, DLC films were prepared by the RF PECVD (Plasma Enhanced Chemical Vapor Deposition) method on silicon substrates using methane ($CH_4$) and hydrogen ($H_2$) gas. We examined the effects of the RF power on the electrical properties of the DLC films. The films were deposited at several RF powers ranging from 50 to 175 W in steps of 25 W. The leakage current of DLC films increased at higher deposition RF power. And the resistivities of DLC films grown at 50 W and 175 W were $5\times10^{11}$ ${\Omega}cm$ and $2.68\times10^{10}$ ${\Omega}cm$, respectively.
Fetal Bovine Serum을 포함한 세포 배양액에 담근 Indium Tin Oxide 전극 계면의 전기화학적 특성
최원석,조성보,Choi, Won Seok,Cho, Sungbo 대한의용생체공학회 2013 의공학회지 Vol.34 No.1
For the biocompatibility test of implantable devices or for the sensitivity evaluation of biomedical sensors, it is required to understand the mechanism of the protein adsorption and the interaction between the adsorbed proteins and cells. In this study, the adsorption of proteins in a cell culture medium with fetal bovine serum onto an indium tin-oxide electrode was characterized by using linear sweep voltammetry and impedance spectroscopy. We immersed the fabricated ITO electrodes in the culture medium for 30, 60, or 90 min, and then measured the electrochemical properties of electrodes with 10 mM $Fe(CN){_6}^{3-/4-}$ and 0.1 M KCl electrolyte. With an increase of contacting time, the anodic peak current was decreased and the charge transfer resistance was increased. However, both parameters were recovered to the values before contact with the medium after the treatment of Trypsin/Ethylenediaminetetraacetic acid hydrolyzing proteins.