http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
다운증후군의 산전진단을 위한 다양한 선별검사의 기여율 비교 - 산전 및 신생아때 진단된 96 례 분석 -
한정열(J . Y . Han),김문영(Y. M . Kim),조준형(J . H . Cho),안현경(H . K . Ahn),류현미(H . M . Ryu),김진미(J . M . Kim),김영미(Y . M . Kim),박소연(S . Y . Park),한혜경(H . K . Han),이영호(Y . H . Lee),양재혁(J . H . Yang) 대한산부인과학회 2000 Obstetrics & Gynecology Science Vol.43 No.10
Objective : The purpose of this study was comparison of the contribution rate for prenatal diagnosis of Down syndrome using various screening methods (Age: greater than or equal to 35 years old, Serum markers: Triple test, Ultrasonography: abnormal sonographic findings, nuchal translucency, nuchal fold thickness).Methods : Total 96 cases of Down syndrome, prenatally or postnatally diagnosed between Jan. 1990 and Sept. 1999, made up the study population. We got the contribution rate of various prenatal screening methods of down syndrome, and obtained the efficiency of various screening program applied for last 10 years. Results : The frequencies of Down syndrome confirmed in prenatal and postnatal were 68 (71%) and 28 (29%) in respectively. The mean age of mother of Down syndrome fetus was 33.0±5.7 years old. The frequency rate of Down syndrome was 0.4, 1.3, 0.7, 0.7, 1.6, 0.7, 1.2, 2.2, 2.0 and 2.3 a 1,000 deliveries from 1990 to 1999 (Y= 0.28+0.18 year, P=0.01). The percentage of Down syndrome diagnosed prenatally was 0 (0/2), 43 (3/7), 50 (2/4), 25 (1/4), 56 (5/9), 100 (5/5), 71 (5/7), 78 (14/18), 78 (14/18) and 89 (17/19) from 1990 to 1999 (Y= 12.9+8.9 year, P=0.000). The contribution rate of prenatal diagnosis for Down syndrome was 30.2±5.6% by age, 18.2±3.4% by triple test and 51.7±6.3% by ultrasonography, and was significantly difference among each screen methods (P=0.008). Conclusions : This study shows that our prenatal screening program is highly effective to detect Down syndrome and especially ultrasonographic findings (abnormal sono findings, Nuchal translucency, Nuchal fold thickness) may be more important than that of age or Triple test to detect the Down syndrome prenatally.
김성윤(SㆍYㆍKim),김유택(YㆍTㆍKim),남청도(CㆍDㆍNam),이영호(YㆍHㆍLee),강호근(HㆍKㆍKang),김성동(SㆍDㆍKim) 한국마린엔지니어링학회 2005 한국마린엔지니어링학회 학술대회 논문집 Vol.2005 No.-
The effect of break down of centrifugal pump due to entrained air has not been clarified yet. Thus, air-water two-phase flow experimental apparatus was installed to clarify the effect of break down. The performance results of a single-phase flow satisfied reappearance. Also, the heads coincided well impeller types.
이영호,최장운,도덕희,Lee, Y.H.,Choi, J.W.,Doh, D.H. 대한설비공학회 1995 설비공학 논문집 Vol.7 No.4
The present numerical study is aimed to investigate time-dependent characteristics of a two-dimensional lid-driven square cavity flow of three high Reynolds numbers, $7.5{\times}10^3$, $10^4$ and $3{\times}10^4$. A conservative convection term on irregular grids was adopted by renewing the MAC type difference schemes on regular grids. Relaxation of velocity and pressure is implemented by SOLA algorithm. In case of $Re=7.5{\times}10^3$, flow behavior converges to steady state after a transient period. But for $Re=10^4$, periodic unsteady sinusoidal fluctuation of local velocity and kinetic energy is found and continuous movements of small eddies in the secondary flow regions are also discovered. Random generation of eddies and their active migrating behavior are detected for $Re=3{\times}10^4$, resulting in complete unsteady and non-linear flow characteristics. And, an organized structure similar to a Moffat vortex is also observed from the time-mean flow patterns. Furthermore, a typoon-like vortex(TLV) appears intemittently and rotates along the separation regions and boundary layers.
마이크로그리드용 순간정전발생기의 순간정전모드 동작시 전류특성 해석
이영호(Y.H. Lee),민병호(B.H. Min),노의철(E.C. Nho),김인동(I.D. Kim),전태원(T.W. Chun),김흥근(H.G. Kim) 전력전자학회 2008 전력전자학술대회 논문집 Vol.- No.-
This paper describes the current characteristics of outage generator for microgrid in outage mode operation. The outage can be generated with 3-phase voltage disturbance generator. The STS current becomes very huge during the first cycle of the outage, and the magnitude of the current depends on the time impedance, series transformer leakage inductance, interfacing reactor of PCS, and the maximum allowable PCS output current. The current and load voltage waveform are analysed through simulation.
이영호(Y.H.Lee),김용환(Y.H.Kim),이광수(G.S.Lee),이현우(H.W.Lee) 전력전자학회 1998 전력전자학술대회 논문집 Vol.- No.-
The development of the high-frequency induction-heating for 2700㎾ power range intend to make localization at forging and rolling mill part by technical innovation And, the development makes to increase our's competitive power at technique, quality and cost. This paper describes the heart of high-frequency induction-heating technique, switching technique, a few problem in common using as an unsatisfied technique, load adjustment technique, system control, diagnostic system, and auto-interface etc.<br/> <br/>
이영호(Y. H. Lee) 한국유체기계학회 1997 유체기계 연구개발 발표회 논문집 Vol.- No.-
The application of PIV to the studies of fluid-machines, especially focused on turbo-machinery is reviewed by scrutinizing the previous investigation. Owing to the inevitable high-speed analysis of turbo-machinery consisting of rotating impellers, the importance of optical setups to cope with illumination problem is frequently mentioned as main ingredient affecting the PIV performance. And the acquisition of the relative velocity and absolute velocity is determined mainly by the optical recording conditions. A few studies cast satisfactory extension of the PIV data to quantitative pressure estimation and related noise assessment.