http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Urapidil, Labetalol의 투여가 기관내 삽관시 심혈관계에 미치는 영향
신용섭,윤석화,손수창,이원형,이정은,황원재,김만수,김영주,김혜자,최세진 충남대학교 의과대학 지역사회의학연구소 1994 충남의대잡지 Vol.21 No.2
We have examined the comparative efficacy of small doses of intravenous urapidil and labetalol in blunting hemodynamic response to endotracheal intubation and surgical incision in 30 patients without cardiovascular diseases. After intravenous urapidil 0.2 mg/kg or labetalol 0.2 mg/kg anesthesia was induced with thiopental 5mg/kg. Endotracheal intubation was facilitated by vecuronium 0.15 mg/kg with priming principle and anesthesia was maintained with enflurane and nitrous oxide in oxygen. Systolic, diastolic and mean arterial pressure and heart rate were measured before administration of the drugs, 5 minute after administration, just prior to endotracheal intubation and 1, 3, 5, 10 minute after intubatin. Also the peak blood pressures and heart rate within 10 minutes after surgical incision were measured. Endotracheal intubation and surgical stimulation were associated with significant increases in blood pressures and heart rate in both urapidil and labetalol group. Comparison of the changes in systolic, diastolic, and mean artrial pressures and heart rate between urapidil and labetalol group showed no significant difference except peak systolic pressure after surgical incision. It is concluded that the pressor response to endotracheal intubation and surgical stimulation are not influenced significantly by urapidil 0.2 mg/kg or labetalol 0.2 mg/kg. However, urapidil and labetalol preloading may be similarly effective in the blunting of the increases in blood pressures with larger doses of the durgs during anesthetic induction.
Man-Seok Son(손만석),Ho-Seung Jin(진호승),Dae-Seok Rho(노대석),Jae-Ha Ko(고재하) 대한전기학회 2020 대한전기학회 학술대회 논문집 Vol.2020 No.11
MVDC(Medium Voltage DC) distribution system has been on the rise for large transmission capacity with low energy loss, undersea power transmission, and so forth. Recently it has been a key part of renewable energy transmission in the smartgrid. However, in the process of the design and the implementation of the protection for the grid, engineers face the difficulties to find MVDC equipments, especially commercialized protection coordination devices, such as DC hybrid CB, solid state CB, VCB, ACB, MCCB, fuse, power contactors(CTR), etc. And those equipments have generally provided the narrow range of the DC rated voltage and the rated current and the power capacity, and given few types of the protective relay with narrow range. It gives a big restriction to design the protection elements and apply the equipments into the grid. This paper presents the protection coordination methods and prepares the actual application for 5kV MVDC grid with distributed generators(DG). The simulation and calculation have been done, the breakers and contactors are chosen, and the setting values of their protective relays and peripherals are found. Now those equipments are in the process of shipment. All of them will be built into the MVDC grid in the site of Naju in the 5kV grid and the ±35 kV grid.
아스픽스(Aspix)를 이용한 KEC 2021 규정에 따른 전력 시설물의 접지 설계 방안
손만석(Man-Seok Son),호세 아르실라(Jose Arcila) 대한전기학회 2021 대한전기학회 학술대회 논문집 Vol.2021 No.11
국내 고압 · 특고압 전력시설물의 경우 KEC 321에 의해 대지전위상승(EPR), 최대허용 접촉 · 보폭전압과 예상 접촉 · 보폭전압과 등을 고려하여 변전실과 전력시설물의 접지를 설계해야 한다. 즉 고압 · 특고압 접지계통의 일반사항에서 접촉전압 및 보폭전압은 허용값 이내의 요건을 만족하여야 하며, 공통접지와 관련된 사항은 KSC IEC 61936-1(교류1 kV 초과 전력설비-제1부 공통규정)의 ‘10. 접지 시스템’에 명기되었다. 그런데 접지를 계산할 때 IEC 61936-1만으로는 최대허용접촉전압과 예상접촉전압을 계산하기에 부족한 점이 있어 ‘IEEE std. 80, Guide for Safety in AC Substation Grounding’를 이용하여야 한다. 본 논문은 고압 이상의 전력시설물의 접지설계를 KEC 규정에 따라 현장에 실적용할 때 필요한 것을 중심으로 계산하는 방법을 서술한다. 특히 계산 과정 중에 복잡한 부분은 아스픽스(Aspix) 접지설계 소프트웨어를 사용하여 결과값을 이론적으로 산출하고, 다른 논문에 나와 있는 소프트웨어 결과와도 비교 분석해 보았다. 또한 이 논문은 IEEE std. 80-2013를 참고하였다.
분산형전원이 연계된 MVDC 마이크로그리드에서 ±35kV와 5kV DC선로의 절연설계 방안
손만석(Man-Seok Son),진호승(Ho-Seung Jin),노대석(Dae-Seok Rho) 대한전기학회 2021 대한전기학회 학술대회 논문집 Vol.2021 No.10
MVDC ±35kV와 5kV 선로 절연설계를 위해 IEC에 제시된 절연거리는 비균질 전계 상태의 내전압과 과도전압, 정상상태 일시 과전압과 반복 첨두전압, 트래킹으로 인한 고장회피에 따라 산출할 수 있다. 또한 요구되는 첨두 내전압 또는 DC 전압을 선정하고 절연에 따른 최소 공간거리와 오염도에 따른 연면거리는 표에 의해 얻을 수 있다. 설비 최고 전압, 정격 단시간 상용주파 내전압, 정격 뇌충격 내전압 1.2/50μs에 따른 최소 당-대지와 상간 이격거리 또한 표에 의해 정할 수 있다. 본 논문에서는 산출된 갑을 근거로 가공전선로와 지중 전선로의 상-대지와 상대상의 이격거리를 산출하였고, 애자와 피뢰기와 종단접속재이 공간거리와 연면거리가 ±35kV와 5kV에 사용되는 기기의 절연에 적합한 갑을 찾고 설계에 반영하였다. 추가하여 실제 적용을 위해서는 선정된 완철, 애자, 피뢰기, 종단접속재, 케이블, 직선접속재를 연결하여 가압시험을 해야 하고, 특히 가공전선로의 구성품들의 강도와 하중에 대한 기계적인 부분의 세밀한 검토가 요구된다.