RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 음성지원유무
        • 원문제공처
          펼치기
        • 등재정보
          펼치기
        • 학술지명
          펼치기
        • 주제분류
          펼치기
        • 발행연도
          펼치기
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • 다이나믹 CMOS PLA의 고장검출을 위한 내장 테스트

        정준모 서경대학교 1998 論文集 Vol.26 No.-

        In this paper built-in test for fault detection of dynamic CMOS PLA is proposed. In the proposed built-in test by proposing the BILBO which can generate initialization patterns and test patterns to detect faults in dynamic CMOS circuit, the testble design for dynamic CMOS PLA, which was difficult in the past because of the problem for detection of stuck-open faults in dynamic CMOS circuit, can be realized easily. And a robust test can be accomplished regardless of input transition skew as the test sequences are generated in consideration of Hamming distance of initialization pattern and test pattern, in addition the length of test sequence is reduced by considering the regular structure of CMOS PLA. And the signal at normal operation can not propagate through BILBO, therefore the problem of signal delay caused by BILBO is solved.

      • FDM에서 경사면의 표면과 면적오차법의 관계에 대한 연구

        전재억,정진서,황영모,김수광,김준안,계중읍,하만경 한국공작기계학회 2002 한국공작기계학회 추계학술대회논문집 Vol.2002 No.-

        In any rapid prototyping process, the layer by layer building process introduces an area error between the staircase and the surface line specified by the computer-aided design model. This affects the dimensional accuracy as well as the surface finish for different part build orientations. This paper describes a methodology for computing the area error for any orientation of the part built by the fused deposition modelling system. This technique can be applied to determine the best build orientation of the part, based on the minimum area error. This technique is verified by comparing the results with the experimental measurements of the area error of the parts built at different orientations.

      • CMOS회로의 고장검출을 위한 전류 테스팅 기법

        정준모 서경대학교 1996 論文集 Vol.24 No.-

        본 논문에서는 전류 테스팅 기법을 이용하여 CMOS회로의 고장 검출 및 위치 결정을 보다 효율적으로 할 수 있는 구조를 제안한다. 기존의 방법에서는 정상 상태 전원 전류에 대한 관찰점이 하나였으나, 제안하는 방법에서는 정상 상태 전원 전류를 두 곳에서 관찰하여 결함으로 인한 과도한 전류가 흐르는 경우를 각각 Vdd에서 입력, 입력에서 GND, 그리고 Vdd에서 GND로 흐르는 경우로 나누어 생각함으로써 고장 검출 및 위치 결정에 유리하도록 보다 많은 고장 부류로 나누어 준다. 또한, 이 구조가 기존의 전류 테스팅 기법으로는 테스팅이 용이하지 않았던 stuck-open 고장 검출에도 쉽게 적용될 수 있음을 보인다. 제시하는 방법에서는 부가 트랜지스터를 이용하며, 정상 상태에서는 전류 경로가 형성되지 않는 CMOS회로에 강제로 전류 경로가 형성되도록 하고, 만일 stuck-open 고장으로 이 경로가 없어지게 되면 해당 전류 경로에 있는 MOS 트랜지스터에 stuck-open 고장이 있음을 알게 된다. 고장을 인가한 회로에 대하여 spice 시뮬레이션을 하고, 트랜지스터 단락 모델을 이용하는 전류 경로 탐색 프로그램을 SUN Sparc Workstation에서 C 언어로 작성하여 전류 경로 탐색 실험을 함으로써, 제안하는 구조의 타당성과 효용성을 입증한다. In this paper a structure that can detect and locate faults in CMOS circuits more efficiently using current testing techniques is proposed. In the conventional method, the observation point of power supply current for stead state was only one, but in proposed method more fault classes are divided for fault detection and location through the observation of power supply current at two points. Also, it is shown that this structure can be easily applied in detection of stuck-open fault which is not easy to test circuits with conventional current testing techniques. In the presented method, a extra transistor is used, and current path is made compulsorily in the CMOS circuits in which no current path can be established in steady state, then it can be known that stuck-open fault is in the MOS transistor on the considering current path, if this path disappears due to stuck-open fault. Through the spice simulation of fault circuits and the experiment using the program of current path search based on transistor of short model written in C language on SUN Spark workstation, the validity and effectiveness is shown.

      • KCI등재
      • 일측성 질폐쇄 및 동측 신장 무발생을 동반한 중복자궁 2예

        윤일영,여소진,김형문,김정식,김태희,이해혁,남계현,이권해,김준모,김민의 순천향의학연구소 2004 Journal of Soonchunhyang Medical Science Vol.10 No.2

        Uterus didelphys with unilateral obstructed hemivagina and ipsilateral renal agenesis usually presents after menarch with progressive abdominal pain during menses secondary to hematocolpos, and indeed a very rare congenital anomaly due to Mullerian duct malformation. An accurate and prompt diagnosis is of importance to permit treatment and to assure the future fertility of the patient. Pelvic ultrasound, physical examination and pelvic MRI established a diagnosis of hematometracolpos secondary to uterus didelphys with unilateral imperforate hemivagina. An incision in the vaginal septum allowed drainage of the hematocolpos, providing relief of the patients symptoms. We report two case of uterus didelphys with obstructed hemivagina with brief review of the literature.

      • 흉요추부 굴곡-신연 손상에서 척추체의 골절 양상

        고영도,김종오,윤여헌,유재두,정준모 대한골절학회 2003 대한골절학회지 Vol.16 No.2

        목적 : 흉요추부 굴곡-신연 손상에 동반되는 척추체의 골절 양상을 알아 보고자 하였다. 대상 및 방법 : 흉요추부 굴곡 - 신연 손상 21례의 방사선 검사를 검토하여 골절된 척추체의 위치, 전후방 추체 높이, 손상된 분절의 후만각, 척추체 골편의 척추관내 침범 정도 및 척추체의 분쇄 정도를 관찰하였다. 결과 : 총 21례 중 압박 골절이 11례, 방출성 골절이 9례 있었다. 척추체 골절은 85%에서 굴곡-신연 손상된 분절내에서 하부 척추체에 위치하였다. 전방 추체 높이는 평균 27% 감소하였고, 압박 골절이 동반된 경우 18%, 방출성 골절이 동반된 경우 40% 감소하였다. 후방 추체 높이는 평균 1% 감소하였고, 압박 골절이 동반된 경우 1% 증가하였으며, 방출성 골절이 동반된 경우 4% 감소하였다. 손상된 분절의 후만각은 평균 19.5도이었고, 압박 골절이 동반된 경우는 15.4도, 방출성 골절이 동반된 경우는 26.8도이었다. 방출성 골절이 동반된 9례 중 골편의 척추관내 침범은 평균 27%이었으며, 척추체의 분쇄 정도는 71.4%에서 경미하였다, 결론 : 흉요추부 굴곡-신연 손상에서 척추세의 골절은 매우 흔하며 분절내 하부 척추체에 호발하였다. 가해진 힘에 비하여 전후방 추체 높이의 감소, 척추관내 침범 및 분쇄 정도가 적었으며, 이는 굴곡력이나 축성 부하의 효과가 신연력에 의해 일부 상쇄되었기 때문이다. Purpose : To evaluate the configuration of vertebral body fractures in flexion-distraction injuries of thoracolumbar spine. Materials and Method : We investigated the location of fractures, anterior or posterior vertebral body height, kyphotic angle of injured segments, canal encreachment and severity of comminution on radiologic examinations of 21 cases. Result : There were 11 compression fractures and 9 burst fractures. 85% of fractures were located in the inferior vertebrae of injured segments. Anterior vertebral height decreased by 27% on average with decrease of 18% in compression fractures and 40% in burst fractures. Posterior height decreased by 1% on average with increase of 1% in compression fractures and decrease of 4% in burst fractures. The average kyphotic angle of injured segments was 19.5˚ with 15.4˚ in compression fractures and 26.8˚ in burst fractures. The canal encreachment in 9 burst fractures was 27% on average, and the comminution of vertebral body was mild in 74%. Conclusion : The fracture of vertebral body in flexion-distraction injuries of thoracolumbar spine was very common, and located on the inferior vertebare of injured segment. The decrease of vertebral height, canal encreachment and severity of comminution was relatively less than the estimated from mechanism of injury, with offset effect of distraction force.

      • SCIESCOPUSKCI등재
      • 지연유합과 불유합에서 저신호 강도 초음파의 유용성

        윤여헌,김종오,고영도,유재두,정준모,오종건,방한천,최창호,신명철 대한골절학회 2003 대한골절학회지 Vol.16 No.1

        목 적 : 저 신호 강도 초음파를 이용한 지연유합과 불유합의 치료에 대한 유용성을 알아보고자 하였다. 대상 및 방법 : 2001년 7월부터 2002년 5월까지 본원에 내원한 지연유합 7례와 불유합 8례를 대상으로 5개월간 저 신호 강도 초음파로 치료하여 5개월후 골유합 여부를 알아 보았다. 결 과 : 총 15례 중 대퇴골 간부 2례, 경골 간부 1례, 상완골 간부 1례, 요골 1례의 지연유합에서 골유합을 얻었고 대퇴골 간부 불유합 3례에서 유합을 얻었다. 지연주합은 71%의 유합율을, 불유합은 37.5%의 유합율을 보였다. 결 론 : 저 신호 강도 초음파는 골유합을 촉진 시킬 수 있으며 지연유합에서 시도해 볼 만 하나 불유합 치료를 위해서는 보다 많은 연구가 필요 하다. Purpose : To evaluation of usefulness of low-intensity ultrasound for nonunion and delayed union. Materials and Methods : For 5 months, we treated 7 delayed union and 8 nonunion using low-intensity ultrasound. After 5 months, in checked X-ray AP and Lateral view, when cortical bridge formation was done, we through union. Results : In 7 delayed union, 5 cases-2 femur, tibia, humerus, radius were healed. In 8 nonunion, 3 femur nonunion were healed. Union rate was 71% in delayed union 37.5% in nonunion. Conclusion : we thought that the low-intensity ultrasound has capacity of induction of union and was considered as the method of treatment for delayed union.

      • 노령의 대퇴 전자간 골절 치료에서 압박고 나사못의 안정성 및 유용성

        김종오,노권재,윤여헌,고영도,유재두,정준모,방한천,정재학 대한골절학회 2003 대한골절학회지 Vol.16 No.2

        목 적: 노령의 대퇴 전자간 골절에서 압박고 나사못의 안정성에 영향을 주는 인자들간의 상관 관계와 골절 양상에 따른 술후 고관절 기능을 평가 및 분석하였다. 대상 및 방법: 압박고 나사를 이용하여 수술적 치료를 시행한 231명의 환자 중 6개월 이상 추시가 가능하였던 60세 이상 84명의 환자들을 대상으로 했다. 방사선적 계측은 압박고 나사못의 활강 길이 및 내반각, 가압 나사 위치, 정복 상태, 원위 골편의 내측 전위를 측정하였으며 술후 기능은 Clawson의 기능 평가표로 하였고 골절 양상에 따라 방사선 계측과 기능 회복과의 상관 관계를 평가하였다. 결 과: 임상 결과는 불안정 골절에서 양호가 10례, 불량이 23례, 안정 골절에서는 양호 40례, 불량이 11례로 안정 골절에서 임상 결과가 좋았고(p<0.001), 압박고 나사 활강은 10 ㎜ 이상일 때 양호가 4례, 불량이 21례, 10 ㎜ 이하에서 양호가 46례, 불량이 13례로 10 ㎜ 이상 활강시에 술후 결과가 불량했다(p<0.001). 다르 방사선적 계측 요인은 결과에 의미있는 차이를 보이지 않았다. 또한, 불안정 골절 중에서 전위 양상 골절의 경우 10㎜ 이상 활강이 12례, 10㎜ 이하 활강이 8례, 분쇄 양상 골절의 경우는 10㎜ 이상이 11례, 10㎜ 이하가 2례로 분쇄 양상의 불안정 골절에서 10㎜ 이상 활강이 의미있게 많았다 (p<0.001). 결 론: 10㎜ 이상의 지연 나사 활강은 고관절 기능 회복 약화를 유발시킬 수 있으며 불안정 골절 분쇄 양상 골절은 이런 지연 나사의 활강이 과도하게 유발될 수 있으므로 불안정 분쇄 양상 골절에서 압박고 나사의 단독 사용은 재고해 보아야 할 것이다. Purpose: To evaluate the relationship between fracture stability and functional results, and analyze the correlation between stability factors and the outcome in intertrochanteric fracture of the elderly. Materials and Methods: Of the 231 patients, 84 patients with age above 60 were able to follow up for minimum 6 months. We measured the sliding length of the lag screw, varus degree, position of lag screw, reduction status and medialization of distal fragment radiologically. The functional outcome of the treatment was evaluated with the Clawson's result classification and we evaluated the correlation between the radiological results of measurement and the functional recovery depending on the Evans fracture classification. Results: There were good results in 40 cases out of 51 stable fractures, and in 10 cases out of 33 unstable fractures (p<0.001). In case of sliding of lag screw more than 10㎜, good results were obtained in 4 cases, and poor in 21. And in case of sliding less than 10㎜, good results were obtained in 46, and poor in 13. (p<0.001).But there was no relationship between other radiologic factors and clinical results. In unstable type, there were 12 cases with lag screw sliding more than 10㎜ and 10 cases with less than 10㎜. In comminuted type, there were 11 cases with lag screw sliding more than 10㎜ and 2 cases with less than 10㎜(p<0.001). Conclusion: The sliding of lag screw more than 10㎜ may result in poor outcome. As in comminuted unstable pattern, sliding of lag screw might be excessive, the use of compression hip screw alone is not good treatment option.

      • KCI등재후보

        당뇨병환자에서 뇨증 Fibronectin농도의 증가에 관한 연구

        한승범,조준승,손건영,서성문,박근용,조성래,박규영,박정모,이인규,여준기 啓明大學校 醫科大學 1994 계명의대학술지 Vol.13 No.4

        Plasma fibronectin is an α₂-glyoprotein, which is produced by vascular endothelial cells. Raised level of plasma fibronectin has been observed in diabetic patients particularly in the presence of microvascular complications. However, no available data exist about urine level of this glycoprotein in diabetic patients. We measured urine fibronectin level by ELISA methods in 54 diabetic patients who have microvascular comlications or not. The following results were obtained. 1) Urine fibronectin level(㎍/g creatinine) in diabetic group(1740.0±678.0) is increased compaired with those in normal control group(471.0±59.0). but this results were not significantly different among two groups(P>0.05). 2) Urine fibronectin level(㎍/g creatinine) was significantly increased in patients with nephropathy (6188.0±3144.0) compared with those in normal control group(471.0±59.0) and patients without nephropathy(645.0±251.0)(P<0.001). 3) There were a significant correlation between BUN, creatinine, creatinine clearance, 24hr urine total protein and urine fibronectin level in diabetic patients. Our data suggest that urine fibronectin excretion level might be used as a sensitive guide for diabectic nephropathy.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼