RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 음성지원유무
        • 원문제공처
          펼치기
        • 등재정보
          펼치기
        • 학술지명
          펼치기
        • 주제분류
          펼치기
        • 발행연도
          펼치기
        • 작성언어
        • 저자
          펼치기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        과채류 육묘용 정밀 두상관수 시스템 개발

        강동현,홍순중,김동억,박민정 (사) 한국생물환경조절학회 2023 생물환경조절학회지 Vol.32 No.1

        This study was conducted to develop a precision automatic irrigation system in a nursery by considering the problems and improvements of manual and the conventional automatic irrigation system. The amount of irrigated water between the conventional automatic irrigation system and manual irrigation was 28.7 ± 4.4 g and 14.2 ± 4.3 g, respectively, and the coefficient of variation was less than 30%. However, the coefficient of variation of the conventional automatic irrigation system of 15%, was higher than that of manual irrigation of 30%. The irrigation test using the developed uniform irrigation system attached with the nozzle of a spray angle 80° and most highest uniformity was at height 600 mm. And coefficient of variation of the irrigation uniformity at the center part was within 20%, but irrigation amount of the edge part was lower 50% and over compared to the center part. As a result of a tomato grafting seedling cultivation test using the developed uniform irrigation system, the average plant height of seedling at the edge part was 28 mm but plant height at the center part was higher as 72 mm. Therefore, it was necessary to apply additional irrigation device at the edge part. The irrigation uniformity of the edge concentrated irrigation system was investigated that the irrigation amount of the edge part was irrigated by more than 50% compared with the center part, and coefficient of variation of the irrigation amount at the center part was less than 30%. As a result of a cucumber grafting seedling cultivation test using the edge concentrated irrigation system, the plant height of seedlings in the edge and central part of cultivation bed were 24% and 26%, respectively, so irrigation uniformity was higher then the uniform irrigation system. In order to improve the uniformity of seedlings, it is necessary to adjust the height of boom according to the growth of the seedling by installing a distance sensor in the overhead watering and boom irrigation system. 본 연구에서는 육묘장에서 인력 또는 관행 자동관수장치의 활용도 조사를 통해 관수장치의 문제점과 그 개선점을 파악하여 균일관수가 가능한 스마트 관수장치를 개발하고 그 성능을 분석하였다. 자동관수와 인력관수의 평균 관수량은 각각 28.7 ±4.4g과 14.2±4.3g으로 두 조건 모두 변동계수가 30% 이내로 균일관수로 판단할 수 있다. 그렇지만 변동계수가 30%인 인력관수에 비해 자동관수는 15%로 균일도가 높았다. 개발된 균일관수장치에 탑재된 분사각이 80°인 노즐은 이론상 600mm 높이에서 가장 균일한 것으로 분석되었고, 균일관수장치를 이용한 관수시험 결과 중앙부의 관수 균일도는 평균대비 20% 이내이지만 가장자리부는 중앙부에 비해 50% 이상 관수량이 적었다. 균일관수장치를 활용한 토마토 접목묘 재배시험 결과, 시험기간 10일간 중앙부는 초장이 평균 72 mm 생장한 데 비해 가장자리부는 평균 28mm 생장하여 가장자리부에 대한 추가 관수가 필요한 것으로 나타났다. 가장자리부 추가 관수장치를 부착하여 관수할 경우 중앙부에 비해 가장자리부의 관수량은 50% 이상이었으며, 중앙부에서는 분사각의 겹침으로 인하여 관수량의 차이는 발생하였으나, 그 차이는 30% 이내였다. 가장자리 집중관수 시스템 활용 시 각지점별 생장 차이는 있으나, 10일간 생육을 비교하면 양측 가장자리의 평균 생장률은 24%, 중앙부의 평균 생장률은 26% 인 점을 고려하면 균일관수장치에 비해 생장 균일도가 높았다. 모종의 초장 균일도 향상을 위해서는 관수장치의 진행방향에 거리센서를 설치하여 작물의 생장에 따라 관수장치의 높이를 조절이 필요할 것으로 판단된다.

      • KCI등재

        전구체의 물성에 따른 리튬 2차전지용 Li(Ni<sub>0.5</sub>Co<sub>0.2</sub>Mn<sub>0.3</sub>)O<sub>2</sub>의 전기화학적 특성 변화

        강동현,채정은,김성수,Kang, Donghyun,Arailym, Nurpeissova,Chae, Jeong Eun,Kim, Sung-Soo 한국전기화학회 2013 한국전기화학회지 Vol.16 No.4

        리튬2차전지용 양극소재인 $Li(Ni_{0.5}Co_{0.2}Mn_{0.3})O_2$를 공침법을 이용해 $Ni_{0.5}Co_{0.2}Mn_{0.3}(OH)_2$ 전구체로부터 합성하였고, 공침조건을 조절하여 전구체의 1차 입자 형상을 Flake형상과 Needle형상으로 제어하였다. 동일한 공정으로 리튬과 혼합하고 열처리하여, 입도, 탭밀도, 화학적 성분 등이 동일한 분체물성의 양극 소재를 합성하였다. 전구체의 1차입자 형상에 따른 $Li(Ni_{0.5}Co_{0.2}Mn_{0.3})O_2$의 전기화학적 특성을 평가하고, 이 특성의 변화를 SEM, XRD, EELS로 이용하여 분석하여 연관성을 고찰하였다. Needle형상 전구체로 합성한 $Li(Ni_{0.5}Co_{0.2}Mn_{0.3})O_2$ 양극의 1차입자는 Flake형상 전구체로 합성한 경우보다 작고, EELS결과로는 입자표면의 Li농도가 내부보다 상대적으로 높았다. 전기화학적인 수명과 출력특성에서 Needle형상 전구체로 합성한 양극이 Flake형상 전구체의 경우보다 우수한 특성을 보였는데, 임피던스 측정으로부터 낮은 전하이동저항에 연관되어 있을 것으로 생각된다. The one of the cathode material, $Li(Ni_{0.5}Co_{0.2}Mn_{0.3})O_2$, was synthesized by the precursor, $Ni_{0.5}Co_{0.2}Mn_{0.3}(OH)_2$, from the co-precipitation method and the morphologies of the primary particle of precursors were flake and needle-shape by controlling the precipitation parameters. Identical powder properties, such as particle size, tap density, chemical composition, were obtained by same process of lithiation and heat-treatment. The relation between electrochemical performances of $Li(Ni_{0.5}Co_{0.2}Mn_{0.3})O_2$ and the primary particle morphology of precursors was analyzed by SEM, XRD and EELS. In the $Li(Ni_{0.5}Co_{0.2}Mn_{0.3})O_2$ cathode from the needle-shape precursor, the primary particle size was smaller than that from flake-shape precursor and high Li concentration at grain edge comparing grain center. The cycle and rate performances of the cathode from needle-shape precursor shows superior to those from flake-shape precursor, which might be attributed to low charge-transfer resistance by impedance measurement.

      • KCI등재
      • 실시간 감정인식을 위한 파형 단위PPG, GSR 신호 기반 1D CNN 기법

        강동현,김덕환 한국차세대컴퓨팅학회 2021 한국차세대컴퓨팅학회 학술대회 Vol.2021 No.05

        Emotion recognition technology, a core for human-robot interaction, must have fast data processing speed and real-time characteristics. This paper proposes an emotion classification method using two bio-signals for real-time emotion recognition. The proposed method is a technique to classify human emotions into three (high or low, neutral arousal / valence) emotions by extracting features from one pulse of PPG(Photoplethysmogram) signal and GSR(Galvanic Skin Response) signal through a 1D CNN model. For real-time emotion recognition, input data requires a short length from 1 to 3 seconds and fast preprocessing. Therefore, in this paper, we use three preprocessing processes and one short pulse of Window size 1.1s without feature extraction, and the label of each pulse uses annotation labeling. The Experiments show that average accuracy is 71.1% arousal and 71.8% valence, confirming the possibility of emotion recognition with pulse-wise data and a real-time possibility with 0.17 seconds of preprocessing time per sample data.

      • KCI등재

        The role of selenium metabolism and selenoproteins in cartilage homeostasis and arthropathies

        강동현,이지연,Wu Cuiyan,Guo Xiong,이병재,전장수,김진홍 생화학분자생물학회 2020 Experimental and molecular medicine Vol.52 No.-

        As an essential nutrient and trace element, selenium is required for living organisms and its beneficial roles in human health have been well recognized. The role of selenium is mainly played through selenoproteins synthesized by the selenium metabolic system. Selenoproteins have a wide range of cellular functions including regulation of selenium transport, thyroid hormones, immunity, and redox homeostasis. Selenium deficiency contributes to various diseases, such as cardiovascular disease, cancer, liver disease, and arthropathy—Kashin–Beck disease (KBD) and osteoarthritis (OA). A skeletal developmental disorder, KBD has been reported in low-selenium areas of China, North Korea, and the Siberian region of Russia, and can be alleviated by selenium supplementation. OA, the most common form of arthritis, is a degenerative disease caused by an imbalance in matrix metabolism and is characterized by cartilage destruction. Oxidative stress serves as a major cause of the initiation of OA pathogenesis. Selenium deficiency and dysregulation of selenoproteins are associated with impairments to redox homeostasis in cartilage. We review the recently explored roles of selenium metabolism and selenoproteins in cartilage with an emphasis on two arthropathies, KBD and OA. Moreover, we discuss the potential of therapeutic strategies targeting the biological functions of selenium and selenoproteins for OA treatment.

      • KCI등재

        점안약의 실온과 냉장보관에서의 2주 간격 연속 균 배양 결과

        강동현,황현지,최성찬,김응수 대한안과학회 2020 대한안과학회지 Vol.61 No.5

        Purpose: We investigated the serial culture of multiuse eye drops applied by medical personnel by intentionally touching the tip of the bottle. Methods: Ten different unpreserved and preserved eye drops including eye drops for allergies, artificial tears, antibiotics, and corticosteroids were included. One bottle was stored at room temperature and the other bottle stored under refrigeration. The experimenter intentionally touched the tip of the bottle with a finger twice daily. The first culture test was performed 2 weeks after contamination and the culture were performed six times; 2 weeks apart. Results: Contamination was noted in three types of eye drops (artificial tears without preservatives, corticosteroids, and anti-allergic eye drops) under refrigerated conditions and four types of eye drops (artificial tears without preservatives, artificial tears with preservatives, corticosteroids, and anti-allergic eye drops) under room temperature conditions. The contamination in 13 eye drops was attributable to five microbial species: Staphylococcus epidermidis (m/c), Staphylococcus hominis, Rhodotorula sp., Corynebacterium sp., and Bacillus sp. Under refrigerated conditions, three eyedrop bottles were contaminated, with five positive cultures in 12 weeks. However, at room temperature, four eye drop bottles were contaminated with eight positive cultures. The culture results changed according to culture time. In some cases, the same result was obtained 2 weeks after the first positive culture but in other cases the result was negative or one of two strains disappeared. Conclusions: Eye drops can be contaminated under both room temperature and refrigerated conditions. We should consider serial culture for eye drops because the culture results could be variable according to time. 목적: 점안약을 인위적으로 오염시킨 후 연속 배양을 통해 미생물의 검출을 알아보고자 하였다. 대상과 방법: 보존제가 첨가된 안약과 첨가되지 않은 안약을 포함하여 총 10가지의 안약을 대상으로 하였다. 점안제에는 항알레르기제, 인공눈물, 항생제, 스테로이드제가 포함되었다. 동일한 안약 두 가지를 준비하여 한 그룹은 상온 보관하였고, 다른 한 그룹은 냉장보관(2-5℃)하였다. 한 명의 실험 연구자에 의해 하루 두 번 병의 입구를 손으로 오염시킨 후 첫 번째 균배양은 2주 뒤에 시행하였고, 두 번째 균배양은 그로부터 2주 간격으로 총 6번 균 배양을 시행하였다. 결과: 냉장보관하에서는 보존제가 없는 인공눈물과 스테로이드제제, 항알레르기제 총 3개의 안약에서 오염이 발견되었다. 상온에서는 보존제가 없는 인공눈물, 보존제가 있는 인공눈물, 스테로이드제, 항알레르기제 4개에서 오염이 발견되었다. 13개의 오염된 안약에서 검출된 균은 5종류였다: S. epidermidis, S. hominis, Rhodotorula spp, Corynebacterium spp, Bacillus spp. 12주간 6번 시행한 균배양에서 냉장보관하 오염된 3개의 안약에서는 양성이 5번 나타났으며, 상온에서 오염된 4개의 안약에서는 8번의 양성이 보였으나 시행한 시간에 따라 변화가 있었다. 결론: 점안약은 상온보관과 냉장보관 모두에서 오염될 수 있다. 균 배양은 검사를 시행한 시간에 따라 달라질 수 있기 때문에 연속적으로 이루어져야 하며 면역체계가 취약한 환자에서는 유의하여 사용하는 것이 중요하다.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼