http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Metal stain on monolithic zirconia restoration: A case report
차민상,이상운,허윤혁,조리라,박찬진 대한치과보철학회 2017 The Journal of Advanced Prosthodontics Vol.9 No.2
In restorative treatment using fixed dental prostheses, dentists should select appropriate restoration material among various types of dental materials. The strength, marginal fit, esthetics, wear resistance, biocompatibility, and cost are important factors in the choice of restoration materials. The present case showed a surface stain on a monolithic zirconia restoration that was due to wear between the monolithic zirconia restoration and the base metal alloy restoration. This phenomenon was confirmed by surface roughness measurement and electron probe micro-analysis.
반투명 지르코니아와 리튬디실리케이트 결정화유리의 물성에 관한 문헌고찰
차민상,김예진,고경호,박찬진,조리라,허윤혁 대한턱관절교합학회 2022 구강회복응용과학지 Vol.38 No.2
Although low translucency 3 mol% yttria stabilized tetragonal zirconia polycrystal has excellent mechanical properties, it has limited application as a monolithic prosthesis. To improve these optical limitations, translucent zirconia has improved esthetics due to an increase in the cubic phase; however, it is accompanied by a decrease in mechanical properties simultaneously. Lithium disilicate has improved its mechanical properties through crystal size reduction and various heat treatment methods; therefore, its clinical application range is continuously increasing. Translucent zirconia shows a wide distribution of physical properties depending on the yttria content and lithium disilicate according to the size and density of crystal grains. As a result, the indications for translucent zirconia and lithium disilicate are increasing. Therefore, in this literature review, we intend to examine the rationale behind the material selection criteria in clinical situations and considerations for designing fixed dental prostheses including pontic, in particular, by summarizing recent studies.
무치악 환자에서 2개의 단일 임플란트 서베이드관을 이용한 임플란트 보조 국소의치 증례: 16개월 경과 관찰 증례 보고
차민상,이상운 대한통합치과학회 2022 대한통합치과학회지 Vol.11 No.2
Prosthetic rehabilitation of a completely edentulous arch might be challenging for both an edentulous patient and a dentist. In case of its irregular residual alveolar ridge and extensive alveolar bone resorption, it is more difficult to obtain adequate support, retention, and stability in the mandible than in the maxilla. In general, an implant-retained overdenture using two implants in the mandibular edentulous anterior region is the known treatment of choice. However, the patient in this case wanted to have teeth placed as in his previous dentition. Moreover, treatment was limited in terms of using sophisticated attachments because the patient had essential hand tremors. For these reasons, the mandible was restored with an implant-assisted removable partial denture (IARPD) using two solitary implantsupported surveyed crowns as abutments. The maxilla was restored with a conventional complete denture. Despite the presence of poor conditions such as high crown-to-implant ratios and isolated locations, marginal bone levels remained stable during the 16-month follow-up period. Above all, the patient was satisfied with the design features of the IARPD clasp and improved masticatory function. However, continuous follow-up is needed to establish the longterm success of this treatment modality
치과용 세라믹의 파단면분석(fractography)에 대한 문헌고찰
송민규,차민상,고경호,허윤혁,박찬진,조리라 대한턱관절교합학회 2022 구강회복응용과학지 Vol.38 No.3
치과용 세라믹의 파절실험 후 파절이 발생한 원인을 분석하면 세라믹의 임상적용 가능성을 높일 수 있다. 파절원인을 파악하기 위한 파단면분석은 주사전자현미경 등 영상기술의 발달로 점차 널리 적용되고 있는데 이를 정확히 해석하기 위해서는 실험조건 설정이 중요하다. 파절시편이 오염되지 않도록 보관하고 세척하며, 관찰을 위해 금속 전처리가 필요하다. 파절은 양상에 따라 주로 금속에서 관찰되는 보조개모양 파절, 열개, 분리파손 및 세라믹에서 관찰되는 피로파절과 조가비 모양 파절이 있다. 세라믹의 주된 파절원인인 피로파절을 실험실에서 재현하기 위해 느린 균열성장을 관찰할 수 있는동적 하중이 필수적이며 하중조건과 하중횟수 등을 적절히 설정해야 한다. 세라믹의 파단면에서 나타나는 대표적인 특징은 해클이며 다양한 해클의 형태를 잘 관찰하여 세라믹 파절의 원인과 과정을 분석할 수 있도록 하는 것이 필요하다. 파단면분석은 치과용 세라믹의 파절을 심층적으로 파악할 수 있는 유용한 방법이므로 정확한 실험과정을 따르고 결과해석에 유의해야 한다.
이상운,차민상,이지혜,조리라,박찬진 대한턱관절교합학회 2020 구강회복응용과학지 Vol.36 No.2
Purpose: The purpose of this study was to compare the axial displacement of the hexagonal and conical abutment in internal conical connection implant after screw tightening and cyclic loading. Materials and Methods: Internal conical connection implants were divided into two groups (n = 10): group HEX, hexagonal abutment; and group CON, conical 2-piece abutments. The axial displacement and removal torque values were measured after 30 Ncm torque tightening and 250N loading test of 100,000 cycles. The Student t test with 5% significance level was used to evaluate the data. Results: HEX group demonstrated significantly higher axial displacement values after 30 Ncm tightening in comparison to the CON group (P < 0.05). No significant difference was found in axial displacement after cyclic loading (P = 0.052). Removal torque loss before and after the cyclic loading both revealed no significant difference between groups (P = 0.057 and P = 0.138). Removal torque value decreased after cyclic loading in both groups (P < 0.05). Conclusion: Overall, both abutment with or without hexagon index presented similar biomechanical performance except HEX group demonstrated significantly more axial displacement after applying tightening torque. (J Dent Rehabil Appl Sci 2020;36(2):95-103)
완전무치악 환자에서 고정성 임플란트 하이브리드 수복물의 임상성적
허윤혁,이양진,권민정,김영균,차민상,Huh, Yoon-Hyuk,Yi, Yang-Jin,Kwon, Min-Jung,Kim, Young-Kyun,Cha, Min-Sang 대한치과보철학회 2013 대한치과보철학회지 Vol.51 No.3
연구 목적: 이 연구의 목적은 완전무치악 환자에서 임플란트 지지 고정성 하이브리드 수복물로 수복한 환자의 임상성적을 알아보는 것이다. 연구 대상 및 방법: 분당서울대병원에서 2003년 10월부터 2009년 11월 사이에 4-6개의 임플란트 지지 고정성 하이브리드 수복물로 수복을 하고 1년 이상 기능한 환자를 대상으로 하였다. 방사선 사진상에서 변연골 흡수량을 측정하고 성별, 해부학적 위치(상악 대 하악), 대합치, 하중시기, 식립 경사도에 따른 차이를 비모수 검정(Mann-Whitney U test) 하고, 외팔보의 길이에 따른 영향을 회귀분석하였으며 합병증을 조사하였다. 유의 수준P<.05로 검정하였다. 결과: 총 16명, 16개 수복물에서 84개의 임플란트의 평균 28개월 후의 골흡수량은 $0.53{\pm}0.39mm$였다. 환자의 성별, 해부학적 위치(상악 대 하악), 대합치, 하중시기에 따른 골흡수량의 유의차는 관찰되지 않았으며(P>.05) 회귀분석 결과 외팔보의 길이와 외팔보 인접 최후방 임플란트의 골흡수량 사이에도 유의성이 없었다(P>.05). 16명중11명의 환자에서 합병증이 발생하였으며 전장재 파절과 인공치 탈락이 가장 많았다. 결론: 짧은 기간의 후향적 연구라는 한계 내에서, 임플란트 지지 고정성 하이브리드 수복물의 평균 골흡수는 매우 적었지만 높은 빈도의 합병증 발생을 보였다. 외팔보 인접 최후방 임플란트의 경사와 관계 없이 외팔보 인접 최후방 임플란트보다 나머지 전방부 임플란트의 변연골 흡수량이 유의하게 컸다. 모든 증례의 외팔보 길이(< 17 mm)는 외팔보 인접 최후방 임플란트 변연골 흡수량에 영향을 주지 않았다. Purpose: The aim of this study was to evaluate clinical outcomes of implant supported fixed-hybrid prostheses (FHP) in the fully edentulous arches. Materials and methods: Patients in this retrospective study were restored with fixed-hybrid prostheses supported by 4 to 6 implants and functioned more than 1 year of loading. Outcome measures were marginal bone change of implant related with sex, anatomical location (maxilla vs. mandible), opposing teeth, loading time of patients, tilting of posterior implant by Mann- Whitney U test and cantilever length of superstructure by regression analysis, and complication rates. Significance level was set P<.05. Results: A total number of 84 implants (16 restorations) placed in 16 patients were observed for 28 months and mean marginal bone loss was $0.53{\pm}0.39mm$. There were no differences of marginal bone loss according to sex, anatomical location (maxilla vs. mandible), opposing teeth, loading time of patients (P>.05), and cantilever length was not significantly related with a marginal bone loss of implant next to cantilever (P>.05). Complication was shown in 11 patients and veneer fracture and dislodging of artificial teeth were most prevalent. Conclusion: Within the limitations of this study, although marginal bone loss of FHP was very little, complication rates were high. Irrespective of tilting of most posterior implants, marginal bone loss of most posterior implants next to cantilever was less than those of the other implants positioned anteriorly. Cantilever length (<17 mm) did not affect a marginal bone loss of most posterior implants.