http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
3D FEM 모델링을 이용한 원전 매설배관의 방식성능 평가 및 결함탐지능 분석
장현영,박흥배,김기태,김영식,장윤영,Chang, Hyun Young,Park, Heung Bae,Kim, Ki Tae,Kim, Young Sik,Jang, Yoon Young 한국압력기기공학회 2015 한국압력기기공학회 논문집 Vol.11 No.2
3D FEM modeling based on 3D CAD data has been performed to evaluate the efficiency of CP system in a real operating nuclear power plant. The results of it successfully produced sophisticated profiles of electrolytic potential and current distributions in the soil of an interested area. This technology is expected to be a breakthrough for detection technology of damages on buried pipes when it comes into combining with a brand of area potential earth current (APEC) and ground penetrated radar (GPR) technologies. 2D current distribution and 2D current vectors on the earth surface from the APEC survey will be used as boundary conditions with exact 3D geometry data resulting in visualization of locations and extents of corrosion damages on the buried pipes in nuclear power plants.
장현영,박채은,이승욱 한국식품과학회 2019 한국식품과학회지 Vol.51 No.5
The present study was conducted to compare antioxidant capacities of protein hydrolysates from four different edible insects (Protaetia brevitarsis larvae, Allomyrina dichotoma larvae, Gryllus bimaculatus imago, and Tenebrio molitor larvae) which have recently been registered as food varieties in Korea. Protein hydrolysates were prepared from each insect using enzymatic hydrolysis using alcalase, and were then separated into a fraction containing ≤3 kDa. According to RC50 values and trolox equivalent antioxidant capacity results obtained from five different antioxidant analyses, the Gryllus bimaculatus (GB) hydrolysate showed relatively high levels of antioxidant capacity and, in particular, the GB hydrolysate showed considerably strong antioxidant activities in 2,2-diphenyl-1-picrylhydrazyl (DPPH) radical scavenging and in ferric reducing antioxidant power (FRAP) assays. The GB hydrolysate also showed the strongest inhibitory effect on peroxidation of linoleic acid, and its rate of inhibition at 100 μg/mL on day 3 of treatment was 60.26%. These results suggest that protein hydrolysates from edible insects including GB represent potential sources of natural antioxidants.
장현영,박희원,유태민,노경운,김현주,Chang, Hyun-Yeong,Park, Hee-Won,You, Tae-Min,Noh, Kyung-Woon,Kim, Hyun-Joo 대한핵의학기술학회 2008 핵의학 기술 Vol.12 No.1
Purpose: CA 19-9 need to examine a number of sample volume, and the postwar 200 U/ml concentration hook effect appears slight. Thus, the antibody-antigen reaction, and by reducing the amount of (sample volume), they can hook effect to minimize the impact of the sample volume and relevance know, I saw the hook effect. In addition, the current maximum of using the standard concentration of the reagent in 240 U/ml increase more than the standard concentration can be seen knows. Material and Method: 5 U/ml and under, make a few low concentration of serum pool from the high concentration of the sample hook effect together with a standard concentration of about 500 to meet the production. The reagents used in experiments are currently using SNUH NM experiment. Orignal method along with the experiment is to 25 ul sample volume (1 / 4), 50 ul (1 / 2), 100 ul (Orignal method) in the experiment. My greatest concentration of the reagent concentration of approximately two times the standard concentration of production. When was the last to make the first experiment, as measured by the standard concentration after that. The new inspection information through a standard solution modified by entering values in them. Results: 100 ul, and to apply the new standard concentration y = 1.3021x - 10.97, $R^2$ = 0.9844. Overall, the results showed a similar orignal method. Because of the concentration in the value of more than 240 U/ml, but it is an overall value that can be made out of a similar value When I put the 50 ul y = 1.045x + 9.5861, $R^2$ = 0.9428. Overall orignal method and the results of a similar value. 50 ul, and to apply the new standard concentration y=1.2006x+11.252, $R^2$=0.9423. Showing a slightly lower value compared with orignal method. Because of the concentration in the value of more than 240 U/ml, but it is an overall value that can be made out of a similar value. When I put the man 25 ul y=0.6012x+24.755, $R^2$=0.4033. Results showed that very small amounts of sample are insecure inside and showed a lower middle cpm orignal method and showed a lot of mismatched. Conclusions: 25 ul of the sample volume is not possible to use the instability had, when I put the 50 ul of the orignal method can be used to show a similar concentration. The new values are slightly lower concentration, The new values are slightly lower concentration, concentration, which are likely due to the lack of data has had a little gap between the sample showed 80 to 200 U/ml additional experiments seem to do. Apply a new 100 ul concentration values are applied to a large crowd is not even in sight. But this way the concentration of 100 to more 400 U/ml gather further experiments should possible adds.
장현영,신선영,이현주,우재룡,이호영,Chang, Hyunyeong,Sin, Sunyoung,Lee, Hyunju,Woo, Jearyong,Lee, Hoyoung 대한핵의학기술학회 2012 핵의학 기술 Vol.16 No.2
Purpose : IRMA method for the experimental reagents, as set out in the manual settings for doing and reporting the test results should, in principle. But many of the reagents allows for the setting of the plot does not have a lot of information. Depending on the angle setting of the table make a difference in test results and what settings are best suited to investigate. Materials and Methods : The hospital has Boramae DREAM10, Cobra, SR-300's using the Immunotech TSH reagents have been compared with the measurements. Since then there using EXCEL calculation of the equipment compared with the measurement. Results : In the comparison between each piece of equipment 1.SR-300: DREAM 10 y = 1.1376x - 0.046 (LOG-LOGIT), 2.SR-300: COBRA y = 1.0985x + 0.042 (LOG-LOG) 3.DREAM10: COBRA y = 0.965x + 0.0887 (LOG-LOG) was the result. In all charts the same X, Y axis, X values were good in general when you have. Linear-Logit value of Cobra Dream10 and Excel tends to match the calculated values provided. Conclusion : Is to guide the B / max, B / Total Logit Y axis of the chart is set to draw a look at the value equation when the X-axis LOG a high concentration are disadvantages rising urgently toward the slope. Linear-Logit plots close to the straight line has a curve. If you have a chart to guide on setting AS setting and therefore, set to guide the absence of information on the need to set up the experiment are thought to pass through.