RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        Calculation of the Allowable Drainage of Parallel Tunnels Based on Ecological Environment Protection

        Helin Fu,Pengtao An,Guowen Cheng,Shujie Wen,Jie Li 대한토목학회 2022 KSCE JOURNAL OF CIVIL ENGINEERING Vol.26 No.5

        To determine a reasonable value of parallel tunnel drainage, a steady-flow calculation model is established. The differential equilibrium equation of seepage is established, and the equation of the falling funnel curve in a steady state with drainage parameters is solved by using boundary conditions. The maximum drawdown depth of the control point is used to calculate the allowable discharge of the tunnel. Then, the curve equation of the falling funnel is determined, the volume of the drainage funnel is calculated, and the total discharge in the steady state is calculated according to the water storage coefficient. Finally, the theoretical formula is verified based on an engineering case and numerical simulation. Considering the actual engineering geology and hydrogeological conditions of the tunnel site, the total drainage, allowable drainage, and initial support bearing head height calculated with the proposed method are different from the actual measurements collected on site by 10%, 18.9% and 13.6%, respectively. Therefore, the calculation method can provide a reference for similar engineering.

      • SCOPUS

        The Numerical Simulation Analysis of Flow Field in Level Control Valve of Water Storage Tank

        Yaping Wang,Lei Gao,Jianghua Ge,Han Gao,Jing Zhang 보안공학연구지원센터 2014 International Journal of Control and Automation Vol.7 No.10

        Level control valve of water storage tank is installed in the outlet of tank, which control the water level of water storage tank by adjusting the water emissions, which make great significance for the safe operation of the super (super) criticality thermal power unit boiler . Complete the simulation analysis of internal flow field by the method of numerical simulation ,in order to achieve structure improvements of level control valve of water storage tank, that make level control valve of water storage tank better meet the work requirements. Establish flow channel model and mesh models of level control valve of water storage tank in various stages of the open process. Make three dimensional viscous numerical simulation of the internal complex flow field by the computational fluid dynamics software of ANSYS CFX. The error between the simulation values of the flow coefficient and the theoretical values , trial values is less than 5% ,which verifies the correctness of the simulation results . Get pressure contour , velocity streamline diagrams and outlet mass flow of level control valve of water storage tank in various stages of the open process. According to the pressure contours and velocity streamline diagrams, make detailed analysis of the flow field of level control valve of water storage tank. According to the dates of outlet mass flow, fit the flow characteristic curve of level control valve of water storage tank. Provide a theoretical basis for the structural design of level control valve of water storage tank.

      • KCI등재

        A Case Study: Evaluation of Water Storage Capacity in Permeable Block Pavement

        박대근,Noe Sandoval,Wuguang Lin,김혜란,조윤호 대한토목학회 2014 KSCE JOURNAL OF CIVIL ENGINEERING Vol.18 No.2

        In every city, low-volume roads and parking lots are composed of dense-graded pavements that increase storm-water runoff;however, urban flooding problems can be prevented if an appropriate pavement system is achieved. One preferable solution to thisproblem for low volume roads and parking lots is to use permeable interlocking block pavement. To determine the storage capacityof this kind of pavement, a series of material property tests were performed such as specific gravity, void ratios, and porosity etc.,which was further used to calculate the water storage capacity of the pavement. And rainfall simulation tests were performed toevaluate surface runoff, delay time, storage capacity, and outflows over two hours. A regression analysis showed that the waterstorage capacity measurement from rain simulation tests agreed with the storage capacity calculation depending on laboratorymaterials-properties tests, based on their high correlation and coefficient values, each within the 95% confidence interval.

      • 빗물저장시설 용수 및 온실온도에 따른 물 대 공기 히트펌프의 냉방 성능 분석

        강연구 ( Younku Kang ),강석원 ( Sukwon Kang ),장재경 ( Jaekyoung Jang ),김영화 ( Youngwha Kim ),성문석 ( Moonseok Sung ),허영길 ( Younggil Hur ) 한국농업기계학회 2016 한국농업기계학회 학술발표논문집 Vol.21 No.2

        제주지역에서는 시설하우스만을 고려하면 빗물이용(저장)시설이 569개소, 저장량 7.9만 톤에 이른다(2014년). 본 연구에서는 제주지역 빗물저장시설 내 빗물을 농업용수로 사용할 뿐만 아니라 히트펌프와 연계하여 냉난방 열원으로 이용하고자 하였으며, 여름철 갈수기 즉 열방출원(heat sink)이 최소인시기의 빗물이용시설 이용 물 대 공기 히트펌프시스템의 냉방성능을 분석하였다. 또한 본 연구에서 적용한 히트펌프는 국내 기업에서 제작한 10RT 규모의 물 대 공기 방식이며, 100톤 규모의 빗물이용시설에 약 20톤의 농업용수를 채운 상태에서 물 대 공기 히트펌프시스템의 응축기 물 입출구 온도, 증발기 공기 입출구온도(Pt 100Ω, Albohn, Germany)와 소비전력(CW240, Yokogawa, Japan)을 측정하여 냉방성능을 분석하였다. 실험온실은 330㎡규모의 망고온실로, 냉방실험은 8월 12일 야간에 온실온도를 34.7℃에서 20℃ 수준으로 냉방하며 수행하였으며, 온실 온도는 약 20℃로 설정하였다. 330㎡규모의 온실을 34.7℃에서 20℃ 내외로 냉방하기 위해 총 6시간이 소요되었다. 이때 외기온은 30.5℃에서 21.7℃로 하강하였다. 히트펌프의 증발기 입구 공기온도가 30℃에서 냉방성능계수는 약 3.2으로 나타났으며 증발기 입구 공기온도가 하강하면서 냉방성능계수도 하강하여 20℃에서 약 2.1로 나타나, 증발기 입구 공기온도가 1℃하강하면서 냉방성능계수는 0.1하강하는 것으로 나타났다. 냉방열량 또한 냉방성능계수와 같이 증발기 입구 공기온도가 하강함에 따라 하강하였으며, 30℃에서 39.8kW, 20℃에서 25.9kW 수준으로 나타났다. 반면 히트펌프의 소비전력은 증발기 입구 공기온도가 30℃에서 20℃로 변하는 동안 큰 변화를 보이지 않았으며, 30℃에서 12.6kW, 20℃에서 12.3kW의 전력을 소비하는 것으로 나타났다. 열방출원(heat sink)로 작용하는 빗물이용시설 내 용수의 응축기 입출구 물온도차에 대한 냉방성능계수 및 냉방 열량은 의 변화는 응축기 입출구 물온도차가 크면 클수록 증가하는 현상으로 보였으며, 응축기 입출구 물온도차가 5.4℃에서 냉방성능계수는 3.2, 냉방열량은 40.7kW 수준, 4℃에서는 각각 2.2, 27.6kW 수준으로 나타났다. 감귤류, 망고 등은 아직까지는 냉방에 대한 요구가 크지 않지만, 빗물이용시설에 충분한 용수를 확보한 후 냉방을 수행하는 것이 좋을 것으로 사료되었다.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼