미니 임플란트 시스템의 적용에 대한 다기관 후향적 임상연구
김영균(Young-Kyun Kim),여인성(In-Sung Yeo),이양진(Yang-Jin Yi),김운규(Un-Kyu Kim),문경남(Kyung-Nam Moon),전승준(Seung-Joon Jeon),조용석(Yong-Seok Cho),윤필영(Pil-Young Yun) 대한구강악안면외과학회 2010 대한구강악안면외과학회지 Vol.36 No.4
Introduction: Mini-implant system is applicable to areas of narrow space and area requiring temporary loading support. The purpose of this study was to evaluate the clinical outcome of a mini-implant system as well as the application of mini-implant system in the dental clinical field. Materials and Methods: The patients who had been operated from Jan 2007 to Dec 2007 in the four dental facility including Seoul National University Bundang Hospital were enrolled. To evaluate the factors associated with the clinical outcome, the patients were classified according to gender, age, area of surgery, type of implant, diameter and length of the implant, and the purpose of the mini-implant system application. Results: From 147 implants, only three implants failed, one of them was for temporary loading. There were no serious surgical or prosthetic complications in this study. Conclusion: An analysis of the preliminary data revealed a satisfactory clinical outcome. However, more long-term evaluation of narrow ridge type as well as the patient’s satisfaction on the use of a provisional type mini-implant system is needed.
Go, Taek-Su,Kim, Seong-Hun,Nelson, Gerald Korean Academy of Dental Science 2011 Journal of korean dental science Vol.4 No.1
Purpose: To describe the newly developed Film image transfer system (FITS) for proper positioning of the orthodontic mini-implant in the narrow interdental space and considerations for better application. Materials and Methods: A patient who was planning to have orthodontic mini-implant treatment on the posterior maxilla was recruited to assess the feasibility of FITS. Dental radiographic film and bite record was taken. And then the film image was transferred on the photographic emulsion coated model using transfer light through film projector (enlarger). After exposing the photo emulsion coating on the model, the image was developed with a working solution for a paper developer and fixed. The surgical guide for the mini-implant was fabricated from the transported FITS data. Results: The completed surgical guide was easily placed intraorally, and allowed a simple and rapid placement of the mini-implant. The site of the implant placement was accurate as planned position. Conclusion: In the reported case, The FITS technique represents an effort to minimize risk to the patient and produce consistently good results based upon accurate information about the anatomy of the implant site.
안상헌 동국대학교 의학연구소 2008 東國醫學 Vol.15 No.1
의치의 안정성과 유지력이 부족할 때, 혹은 상하악 전치부와 같이 폭경이 좁아 일반적인 임플란트의 사용이 곤란한 경우 미니임플란트를 이용하면 그 문제점을 해결할 수 있다. 본 교실에서는 미니임플란트를 이용한 보철수복 증례들을 문헌고찰과 함께 보고하는 바이다. The lack of proper stability and retention is frequently found in mandibular complete dentures. The conventional implants have no use for the shortness of mesio-distal width such as maxillary and mandibular incisors. Mini dental implant system will resolve the above-mentioned problems.