RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        Value of CT in the Discrimination of Fatal from Non-Fatal Stercoral Colitis

        Cheng-Hsien Wu,Chen-Chih Huang,Li-Jen Wang,Yon-Cheong Wong,Chao-Jan Wang,Wan-Chak Lo,Being-Chuan Lin,Yung-Liang Wan,Chuen Hsueh 대한영상의학회 2012 Korean Journal of Radiology Vol.13 No.3

        Objective: Clinical presentation and physical signs may be unreliable in the diagnosis of stercoral colitis (SC). This study evaluates the value of computed tomography (CT) in distinguishing fatal from non-fatal SC. Materials and Methods: Ten patients diagnosed as SC were obtained from inter-specialist conferences. Additional 13 patients with suspected SC were identified via the Radiology Information System (RIS). These patients were divided into two groups; fatal and non-fatal SCs. Their CT images are reviewed by two board-certified radiologists blinded to the clinical data and radiographic reports. Results: SC occurred in older patients and displayed no gender predisposition. There was significant correlation between fatal SC and CT findings of dense mucosa (p = 0.017), perfusion defects (p = 0.026), ascites (p = 0.023), or abnormal gas (p = 0.033). The sensitivity, specificity, and accuracy of dense mucosa were 71%, 86%, and 81%, respectively. These figures were 75%, 79%, and 77% for perfusion defects; 75%, 80%, and 78% for ascites; and 50%, 93%, and 78% for abnormal gas, respectively. Each CT sign of mucosal sloughing and pericolonic abscess displayed high specificity of 100% and 93% for diagnosing fatal SC, respectively. However, this did not reach statistical significance in diagnosing fatal SC. Conclusion: CT appears to be valuable in discriminating fatal from non-fatal SC. Objective: Clinical presentation and physical signs may be unreliable in the diagnosis of stercoral colitis (SC). This study evaluates the value of computed tomography (CT) in distinguishing fatal from non-fatal SC. Materials and Methods: Ten patients diagnosed as SC were obtained from inter-specialist conferences. Additional 13 patients with suspected SC were identified via the Radiology Information System (RIS). These patients were divided into two groups; fatal and non-fatal SCs. Their CT images are reviewed by two board-certified radiologists blinded to the clinical data and radiographic reports. Results: SC occurred in older patients and displayed no gender predisposition. There was significant correlation between fatal SC and CT findings of dense mucosa (p = 0.017), perfusion defects (p = 0.026), ascites (p = 0.023), or abnormal gas (p = 0.033). The sensitivity, specificity, and accuracy of dense mucosa were 71%, 86%, and 81%, respectively. These figures were 75%, 79%, and 77% for perfusion defects; 75%, 80%, and 78% for ascites; and 50%, 93%, and 78% for abnormal gas, respectively. Each CT sign of mucosal sloughing and pericolonic abscess displayed high specificity of 100% and 93% for diagnosing fatal SC, respectively. However, this did not reach statistical significance in diagnosing fatal SC. Conclusion: CT appears to be valuable in discriminating fatal from non-fatal SC.

      • KCI등재

        The simple and easy way to manufacture counter electrode for dye-sensitized solar cells

        Jo-Lin Lan,Yung-Yun Wang,Chi-Chao Wan,Tzu-Chien Wei,Hsien-Ping Feng,Chao Peng,Hai-Peng Cheng,Ya-Huei Chang,Wen-Chi Hsu 한국물리학회 2010 Current Applied Physics Vol.10 No.2

        We previously developed poly-N-vinyl-2-pyrrolidone (PVP)-capped Pt nanoclusters on ITO glass via a simple ‘‘2-step dip coating process” as counter electrode for DSSC. This new counter electrode was examined by transmission electron microscopy (TEM), inductively coupled plasma-atomic emission spectroscopy (ICP-AES), electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV), and current–voltage curve (I–V curve). The TEM results revealed that PVP-capped Pt nanoclusters’ size is about 3 nm, and the amount of Pt deposited on ITO glass is about 5 ㎍/㎠. Comparing with sputtered Pt and Solaronix thermal cluster Pt-catalyst T/SP, the PVP-capped Pt counter electrode has lower amount of Pt deposited on TCO glass,more positive potential of tri-iodide reduction, and better performance for the charge-transfer resistance (RCT) and the cell efficiency (g).

      • KCI등재

        Effects of Propranolol on the Left Ventricular Volume of Normal Subjects During CT Coronary Angiography

        Yuan Heng Mo,Fu Shan Jaw,Yung Cheng Wang,Chin Ming Jeng,Shinn Forng Peng 대한영상의학회 2011 Korean Journal of Radiology Vol.12 No.3

        Objective: The purpose of this study is to determine the effects of propranolol on the left ventricular (LV) volume during CT coronary angiography. Materials and Methods: The LV volume of 252 normal Chinese subjects (126 subjects with propranolol medication and 126 age- and gender-matched Chinese subjects without medication) was estimated using 64 slices multi-detector CT (MDCT). The heart rate difference was analyzed by the logistic linear regression model with variables that included gender, age, body height, body weight, systolic blood pressure (SBP), diastolic blood pressure (DBP) and the dosage of propranolol. The following global LV functional parameters were calculated: the real-end diastolic volume (EDV), the real-end systolic volume (ESV) and the real-ejection fraction (EF). Results: The female subjects had a greater decrease of heart rate after taking propranolol. The difference of heart rate was negatively correlated with the dosage of propranolol. The real-EDV, the real-ESV and the real-EF ranged from 48.1 to 109 mL/m2, 6.1 to 57.1 mL/m2 and 41% to 88%, respectively. There was no significant difference in the SBP and DBP between the groups without and with propranolol medication (123 ± 17 and 80 ± 10 mmHg; 120 ± 14 and 80 ± 11 mmHg, respectively). The real-EDV showed no significant difference between these two groups, but the real-ESV and real-EF showed significant differences between these two groups (69.4 ± 9.3 and 70.6 ± 8.9 mL/m2; 23.5 ± 5.7 and 25.6 ± 3.7 mL/m2, 66.5 ± 5.1% and 63.5 ± 4.6%, respectively). Conclusion: The difference of heart rate is significantly influenced by gender and the dosage of propranolol. Propranolol will also increase the ESV, which contributes to a decreased EF, while the SBP, DBP and EDV are not statistically changed. Objective: The purpose of this study is to determine the effects of propranolol on the left ventricular (LV) volume during CT coronary angiography. Materials and Methods: The LV volume of 252 normal Chinese subjects (126 subjects with propranolol medication and 126 age- and gender-matched Chinese subjects without medication) was estimated using 64 slices multi-detector CT (MDCT). The heart rate difference was analyzed by the logistic linear regression model with variables that included gender, age, body height, body weight, systolic blood pressure (SBP), diastolic blood pressure (DBP) and the dosage of propranolol. The following global LV functional parameters were calculated: the real-end diastolic volume (EDV), the real-end systolic volume (ESV) and the real-ejection fraction (EF). Results: The female subjects had a greater decrease of heart rate after taking propranolol. The difference of heart rate was negatively correlated with the dosage of propranolol. The real-EDV, the real-ESV and the real-EF ranged from 48.1 to 109 mL/m2, 6.1 to 57.1 mL/m2 and 41% to 88%, respectively. There was no significant difference in the SBP and DBP between the groups without and with propranolol medication (123 ± 17 and 80 ± 10 mmHg; 120 ± 14 and 80 ± 11 mmHg, respectively). The real-EDV showed no significant difference between these two groups, but the real-ESV and real-EF showed significant differences between these two groups (69.4 ± 9.3 and 70.6 ± 8.9 mL/m2; 23.5 ± 5.7 and 25.6 ± 3.7 mL/m2, 66.5 ± 5.1% and 63.5 ± 4.6%, respectively). Conclusion: The difference of heart rate is significantly influenced by gender and the dosage of propranolol. Propranolol will also increase the ESV, which contributes to a decreased EF, while the SBP, DBP and EDV are not statistically changed.

      • KCI등재

        Validation of Pharyngeal Acid Reflux Episodes Using Hypopharyngeal Multichannel Intraluminal Impedance-pH

        Yen-Yang Chen,Chen-Chi Wang,Ying-Cheng Lin,John Y Kao,Chun-Yi Chuang,Yung-An Tsou,Ja-Chih Fu,Sheng-Shun Yang,Chi-Sen Chang,Han-Chung Lien 대한소화기 기능성질환∙운동학회 2023 Journal of Neurogastroenterology and Motility (JNM Vol.29 No.1

        Background/AimsHypopharyngeal multichannel intraluminal impedance-pH (HMII-pH) technology incorporating 2 trans-upper esophageal sphincter impedance channels has been developed to detect pharyngeal reflux. We used the HMII-pH technique to validate the candidate pharyngeal acid reflux (PAR) episodes based on the dual-pH tracings and determined the interobserver reproducibility. MethodsWe conducted a cross-sectional study in tertiary centers in Taiwan. Ninety patients with suspected laryngopharyngeal reflux and 28 healthy volunteers underwent HMII-pH test when off acid suppressants. Candidate PAR episodes were characterized by pharyngeal pH drops of at least 2 units and reaching a nadir pH of 5 within 30 seconds during esophageal acidification. Two experts manually independently identified candidate PAR episodes based on the dual-pH tracings. By reviewing the HMII-pH tracings, HMII-pH-proven PAR episodes were subsequently confirmed. The consensus reviews of HMII-pH-proven PAR episodes were considered to be the reference standard diagnosis. The interobserver reproducibility was assessed. ResultsA total of 105 candidate PAR episodes were identified. Among them 84 (80.0%; 95% CI, 71.0-87.0%) were HMII-pH-proven PAR episodes (82 in 16 patients and 2 in 1 healthy subject). Patients tended to have more HMII-pH-proven PAR episodes than healthy controls (median and percentile values [25th, 75th, and 95th percentiles]: 0 [0, 0, 3] vs 0 [0, 0, 0], P = 0.067). The concordance rate in diagnosing HMII-pH-proven PAR episodes between 2 independent observers was 92.2%. ConclusionOur preliminary data showed that 80.0% (71.0-87.0%) of the proposed candidate PAR episodes were HMII-pH-proven PAR episodes, among which the interobserver reproducibility was good.

      • KCI등재

        Distal Mean Nocturnal Baseline Impedance Predicts Pathological Reflux of Isolated Laryngopharyngeal Reflux Symptoms

        Hua-Nong Luo,Chen-Chi Wang,Ying-Cheng Lin,Chun-Yi Chuang,Yung-An Tsou,Ja-Chih Fu,Sheng-Shun Yang,Chi-Sen Chang,Han-Chung Lien 대한소화기 기능성질환∙운동학회 2023 Journal of Neurogastroenterology and Motility (JNM Vol.29 No.2

        Background/AimsDiagnosis of isolated laryngopharyngeal reflux symptoms (ILPRS), ie, without concomitant typical reflux symptoms (CTRS), remains difficult. Mean nocturnal baseline impedance (MNBI) reflects impaired mucosal integrity. We determined whether esophageal MNBI could predict pathological esophagopharyngeal reflux (pH+) in patients with ILPRS. MethodsIn this cross-sectional study conducted in Taiwan, non-erosive or low-grade esophagitis patients with predominant laryngopharyngeal reflux symptoms underwent combined hypopharyngeal multichannel intraluminal impedance-pH monitoring when off acid suppressants. Participants were divided into the ILPRS (n = 94) and CTRS (n = 63) groups. Asymptomatic subjects without esophagitis (n = 25) served as healthy controls. The MNBI values at 3 cm and 5 cm above the lower esophageal sphincter (LES) and the proximal esophagus were measured. ResultsDistal but not proximal esophageal median MNBI values were significantly lower in patients with pH+ than in those with pH– (ILPRS in pH+ vs pH–: 1607 Ω vs 2709 Ω and 1885 Ω vs 2563 Ω at 3 cm and 5 cm above LES, respectively; CTRS in pH+ vs pH–: 1476 vs 2307 Ω and 1500 vs 2301 Ω at 3 cm and 5 cm above LES, respectively, P < 0.05 for all). No significant differences of any MNBI exist between any pH– subgroups and healthy controls. The areas under the receiver operating characteristic curve in the ILPRS group were 0.75 and 0.80, compared to the pH– subgroup and healthy controls (P < 0.001 for both), respectively. Interobserver reproducibility was good (Spearman correlation 0.93, P < 0.0001). ConclusionDistal esophageal MNBI predicts pathological reflux in patients with ILPRS.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼