http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Design of Real-Time Autonomic Nervous System Evaluation System Using Heart Instantaneous Frequency
Yeon-Sik Noh,Sung-Jun Park,Sung-Bin Park,Hyung-Ro Yoon 대한전기학회 2008 Journal of Electrical Engineering & Technology Vol.3 No.4
In this study, we attempt to design a real-time autonomic nervous system (ANS) evaluation system usable during exercise using heart instantaneous frequency (HIF). Although heart rate variability (HRV) is considered to be a representative signal widely used ANS evaluation system, the R-peak detection process must be included to obtain an HRV signal, which involves a high sampling frequency and interpolation process. In particular, it cannot accurately evaluate the ANS using HRV signals during exercise because it is difficult to detect the R-peak of electrocardiogram (ECG) signals with exposure to many noises during exercise. Therefore, in this study, we develop the ground for a system that can analyze an ANS in real-time by using the HIF signal circumventing the problem of the HRV signal during exercise. First, we compare the HRV and HIF signals in order to prove that the HIF signal is more efficient for ANS analysis than HRV signals during exercise. Further, we performed real-time ANS analysis using H1F and confirmed that the exerciser's ANS variation experiences massive surges at points of acceleration and deceleration of the treadmill (similar to HRV).
Design of Real-Time Autonomic Nervous System Evaluation System Using Heart Instantaneous Frequency
Noh, Yeon-Sik,Park, Sung-Jun,Park, Sung-Bin,Yoon, Hyung-Ro The Korean Institute of Electrical Engineers 2008 Journal of Electrical Engineering & Technology Vol.3 No.4
In this study, we attempt to design a real-time autonomic nervous system(ANS) evaluation system usable during exercise using heart instantaneous frequency(HIF). Although heart rate variability(HRV) is considered to be a representative signal widely used ANS evaluation system, the R-peak detection process must be included to obtain an HRV signal, which involves a high sampling frequency and interpolation process. In particular, it cannot accurately evaluate the ANS using HRV signals during exercise because it is difficult to detect the R-peak of electrocardiogram(ECG) signals with exposure to many noises during exercise. Therefore, in this study, we develop the ground for a system that can analyze an ANS in real-time by using the HIF signal circumventing the problem of the HRV signal during exercise. First, we compare the HRV and HIF signals in order to prove that the HIF signal is more efficient for ANS analysis than HRV signals during exercise. Further, we performed real-time ANS analysis using HIF and confirmed that the exerciser's ANS variation experiences massive surges at points of acceleration and deceleration of the treadmill(similar to HRV).
Rat의 복강에 삽입한 Fluorouracil-Polyglycolic acid 제형의 Fluorouracil 용출에 관한 연구
노승무,정경수,오정연,김진향,양준묵,강대영,송규상,최정목,최선웅,이진호,조준식,민병무,김용백,김창식,박근성,김승영,김학용,인현빈 忠南大學校 癌共同硏究所 1998 癌共同硏究所 硏究誌 Vol.2 No.1
A common form of relapse in adenocarcinoma of the stomach is intraperitoneal dissemination, in fact, among gastric adenocarcinoma patients who have undergone surgery intended to cure, approximately 50% of the patients develope initial recurrence in the peritoneal cavity regardless of the anatomic site of the primary tumor within the stomach. The efficacy of systemic postoperative chemotherapy to prevent peritoneal recurrence of gastrric adcnocarcinoma is not satisfactory. There is still a great need for improved therapeutic strategies on the disseminated microscopic disease and small miliary nodules remaining on the peritoneal surface or lymphatics after operation. The authers have made fluorouracil-polyglycolic acid composite disks(Fu-PGA disks) with fluorouracil and biodegradable polymer: polyglycolic acid for more effective intraperitoneal chemotherapy. We inserted the Fu-PGA disk(s) in the peritoneal cavity of rat and pharmacokinetic study was performed to measure fluorouracil concentration in the peritoneal fluid, plasma, liver, kidney and heart tissue at 24 hour, 72 hour and 168 hour after insertion of Fu-PGA disk(s). Myelosuppressive action of this composite also was determined following its administration. The data of this study suggested that Fu-PGA composite will be a new device releasing drugs in a controlled manner and having targetability to peritoneum, and this device will be improving the efficacy of intraperitoneal chemotherapy for gastric adenocarcinoma.
위암환자의 복강내에 투여한 Mitomycin C-Carbon Particle의 Mitomycin 용출에 관한 연구
노승무,조영훈,정경수,오정연,김진향,양준묵,강대영,송규상,조준식,최선웅,이진호,민병무,김용백,김창식,박근성,인현빈,정현용,김학용 충남대학교 의과대학 지역사회의학연구소 1998 충남의대잡지 Vol.25 No.1
Locoregional recurrence is the most common type of recurrence in surgical operation of gastric adenocarcinoma, and peritoneal dissemination is one of the most difficult problems in advanced gastric adenocarcinoma treatment. Because the peritoneal cavity is the most common site of the first recurrence after gastric cancer resection, intraperitoneal chemotherpy seems a logical choice for cancer chemotherapy. The Mitomycin C(MMC) adsorbed by the activated charcoal particles(CH) is relatively released when the drug concentration surrounding the carbon particles becomes low in the peritoneum of the peritoneal cavity. For the intraperitoneal chemotherapy on the advanced gastric adenocarcnoma, mitomycin C adsorbed on activated carbon particles was administered in the peritoneal cavity just before abdominal wall closure. The closed drainage tubes were inserted in the peritoneal cavity and clamped for tuo hours after completion of operation. MMC concentrations were serially measured in peritoneal fluid, plasma and urine at 2hour, 48 hour, 72 hour and 168 hour following its administration in order to study the efficacy of the MMC-CH as a drug delivery system. There were minimal toxicities in born marrow, liver, and gastrointestinal system after intraperitoneal MMC-CH administration. The data of this study suggested that MMC-CH may have a somewhat more beneficial effect than surgery alone when administered in optimal dose and schedules, but the MMC concentration of the peritoneal fluid was not sufficient to eradicate remnant cancer cells, and effective duration of maintenance was only below 24 hours in the peritoneal fluid and plasma.
Rat의 복강에 삽입한 Filorouracil-Polyglycolic acid제형의 Fluorouracil용출에 관한 연구
노승무,정경수,오정연,김진향,양준묵,강대영,송규상,최정목,최선웅,이진호,조준식,민병무,김용백,김창식,박근성,김승영,김학용,인현빈 충남대학교 의과대학 지역사회의학연구소 1998 충남의대잡지 Vol.25 No.1
A common form of relapse in adenocarcinoma of the stomach is intraperitioneal dissemination, in fact, among gastric adenocarcinoma patients who have undergone surgery intended to cure, approximately 50% of the patients develope initial recurrence in the peritoneal cavity regardless of the anatomic site of the primary tumor within the stomach. The efficacy of systemic postoperative chemotherapy to prevent peritoneal recurrence of gastrric adenocarcinoma is not satisfactory. There is still a great need for improved therapeutic strategies on the disseminated microscopic disease and small miliary nodules remaining on the peritoneal surface or lymphatics after operation. The authers have made fluorouracil-polyglycolic acid composite disks(Fu-PGA disks) with fluorouracil and biodegradable polymer: polyglycolic acid for more effective intraperitoneal chemotherapy. We inserted the Fu-PGA disk(s) in the peritoneal cavity of rat and pharmacokinetic study was performed to measure fluorouracil concentration in the peritoneal fluid, plasma, liver, kidney and heart tissue at 24 hour, 72 hour and 168 hour after insertion of Fu-PGA disk(s). Myelosuppressive action of this composite also was determined following its administration. The data of this study suggested that Fu-PGA composite will be a new device releasing drugs in a controlled manner and having targetability to peritoneum, and this device will be improving the efficacy of intraperitoneal chemotherapy for gastric adenocarcinoma.