http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Jeong Hyoun Yoon,Ki Dae Han,Da Hye Jeon,Eun Sang Park,Joo Ho Oh,Duk Won Kang,Chan Young Lee,Seong Woo Lee 한국방사성폐기물학회 2023 한국방사성폐기물학회 학술논문요약집 Vol.21 No.2
KORAD (Korea Radioactive Waste Agency, http://www.korad.or.kr) has stored slightly contaminated ascon (asphalt coated concrete mixture) that was introduced to Gyeongju repository about a decade ago waiting for a final disposal. It is believed to be mainly contaminated by radioisotope 137Cs due to impurities introduced from the outside during the ascon manufacturing process. We studied characteristics of the radioactive waste to see whether this material would be proper enough to be disposed in Gyeongju LILW repository or be other ways to reduce the disposal volume including self-disposal before its final disposal otherwise. KORAD looked into the properness of characteristics of ascon in terms of WAC (Waste Acceptance Criteria) documented by KORAD that includes general chemical and physical properties of asphalt, density, size of grains, content of organic material and possibility of existence of chelate materials that qualitatively limited to be disposed by the criteria. And other associated characteristics such as gas generation and bio degradation were also investigated. Based on the data obtained from the study, we proposed various plausible solutions in associated with operational and disposal safety and economic view points. This study will be used for KORAD’s decision on how to control and safely dispose the spent ascon within a reasonable time period. And also those experiences may be applied for other LILW issues that require treatment or conditioning of radioactive wastes in the future.
Yoon, Min A.,Kim, Se Hyung,Lee, Jeong Min,Woo, Hyoun Sik,Lee, Eun Sun,Ahn, Se Jin,Han, Joon Koo Lippincott Williams Wilkins, Inc. 2012 Journal of computer assisted tomography Vol.36 No.5
OBJECTIVES: To evaluate the diagnostic performance of computed tomography (CT) colonography (CTC) reconstructed with different levels of adaptive statistical iterative reconstruction (ASiR, GE Healthcare) and Veo (model-based iterative reconstruction, GE Healthcare) at various tube currents in detection of polyps in porcine colon phantoms. METHODS: Five porcine colon phantoms with 46 simulated polyps were scanned at different radiation doses (10, 30, and 50 mA s) and were reconstructed using filtered back projection (FBP), ASiR (20%, 40%, and 60%) and Veo. Eleven data sets for each phantom (10-mA s FBP, 10-mA s 20% ASiR, 10-mA s 40% ASiR, 10-mA s 60% ASiR, 10-mA s Veo, 30-mA s FBP, 30-mA s 20% ASiR, 30-mA s 40% ASiR, 30-mA s 60% ASiR, 30-mA s Veo, and 50-mA s FBP) yielded a total of 55 data sets. Polyp detection sensitivity and confidence level of 2 independent observers were evaluated with the McNemar test, the Fisher exact test, and receiver operating characteristic curve analysis. Comparative analyses of overall image quality score, measured image noise, and interpretation time were also performed. RESULTS: Per-polyp detection sensitivities and specificities were highest in 10-mA s Veo, 30-mA s FBP, 30-mA s 60% ASiR, and 50-mA s FBP (sensitivity, 100%; specificity, 100%). The area-under-the-curve values for the overall performance of each data set was also highest (1.000) at 50-mA s FBP, 30-mA s FBP, 30-mA s 60% ASiR, and 10-mA s Veo. Images reconstructed with ASiR showed statistically significant improvement in per-polyp detection sensitivity as the percent level of per-polyp sensitivity increased (10-mA s FBP vs 10-mA s 20% ASiR, P = 0.011; 10-mA s FBP vs 10-mA s 40% ASiR, P = 0.000; 10-mA s FBP vs 10-mA s 60% ASiR, P = 0.000; 10-mA s 20% ASiR vs 40% ASiR, P = 0.034). Overall image quality score was highest at 30-mA s Veo and 50-mA s FBP. The quantitative measurement of the image noise was lowest at 30-mA s Veo and second lowest at 10-mA s Veo. There was a trend of decrease in time required for image interpretation as the percent level of ASiR increased, and ASiR or Veo was used instead of FBP. However, differences from comparative analyses of overall image quality score, measured image noise, and interpretation time did not reach statistical significance. CONCLUSION: ASiR and Veo showed improved diagnostic performance with excellent sensitivity and specificity with less image noise and good image quality compared with FBP reconstruction of same radiation dose. Our study confirmed feasibility of low-dose CTC with iterative reconstruction as a promising screening tool with excellent diagnostic performance similar to that of the standard-dose CTC with FBP.
윤병석,임익현,정태섭 전북대학교 공학연구원 ( 구 전북대학교 공업기술연구소 ) 2003 工學硏究 Vol.34 No.-
This study is performed to odor predictions at paper manufactory, to provide guideline for design and evaluation of facility construction and operations. Odor and VOCs materials were measured at five points as incinerator, DIP and TMP. The results show that odors are observed in Hydrogen Sulfide, Mercaptan, stylene and VOCs are detected in alkane, terpene. Especially, pinenes among terpenes are detected a lot because of character of paper manufactory. In order to analysis quality and quantity of VOCs at stack, the operation temperature of milling dryers outlet was changed to 100℃ and 120℃. The results show that discharge of alkanes and concentration of VOCs measured at the 4 part decreases significantly but terpenes is quite abundant in operation at 100℃ than 12 0℃.