http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Okazaki, Tohru,Hayashi, Hiroaki,Takegami, Kazuki,Okino, Hiroki,Kimoto, Natsumi,Maehata, Itsumi,Kobayashi, Ikuo The Korean Association for Radiation Protection 2016 방사선방어학회지 Vol.41 No.3
Background: In order to manage the patient exposure dose in X-ray diagnosis, it is preferred to evaluate the entrance skin dose; although there are some evaluations about entrance skin dose, a small number of report has been published for direct measurement of patient. We think that a small-type optically stimulated luminescence (OSL) dosimeter, named nanoDot, can achieve a direct measurement. For evaluations, the corrections of angular and energy dependences play an important role. In this study, we aimed to evaluate the angular and the energy dependences of nanoDot. Materials and Methods: We used commercially available X-ray diagnostic equipment. For angular dependence measurement, a relative response of every 15 degrees of nanoDot was measured in 40-140 kV X-ray. And for energy dependence measurement, mono-energetic characteristic X-rays were generated using several materials by irradiating the diagnostic X-rays, and the nanoDot was irradiated by the characteristic X-rays. We evaluated the measured response in an energy range of 8.1-75.5 keV. In addition, we performed Monte-Carlo simulation to compare experimental results. Results and Discussion: The experimental results were in good agreement with those of Monte-Carlo simulation. The angular dependence of nanoDot was almost steady with the response of 0 degrees except for 90 and 270 degrees. Furthermore, we found that difference of the response of nanoDot, where the nanoDot was irradiated from the randomly set directions, was estimated to be at most 5%. On the other hand, the response of nanoDot varies with the energy of incident X-rays; slightly increased to 20 keV and gradually decreased to 80 keV. These results are valuable to perform the precise evaluation of entrance skin dose with nanoDot in X-ray diagnosis. Conclusion: The influence of angular dependence and energy dependence in X-ray diagnosis is not so large, and the nanoDot OSL dosimeter is considered to be suitable dosimeter for direct measurement of entrance surface dose of patient.
( Norihiro Furusyo ),( Ahmed H. Walaa ),( Kunimitsu Eiraku ),( Kazuhiro Toyoda ),( Eiichi Ogawa ),( Hiroaki Ikezaki ),( Takeshi Ihara ),( Takeo Hayashi ),( Mosaburo Kainuma ),( Masayuki Murata ),( Jun 대한간학회 2011 Gut and Liver Vol.5 No.4
Background/Aims: Helicobacter pylori infection causes gastritis, peptic ulcers and gastric malignancies, and its eradication has been advocated by many groups. We determined the H. pylori carrier status and eradication rates of patients with chronic hepatitis C virus (HCV) infection. Methods: In total, 76 chronically HCV-infected patients were enrolled for comparison with 228 HCV-noninfected, age- and sex-matched controls. H. pylori infection was confirmed by H. pylori antibody and urea breath testing. Results: The H. pylori infection rate was significantly higher for HCV-infected patients (67 of 76, 88.2%) than for HCV-noninfected controls (158 of 228, 69.3%). Endoscopic fi ndings showed that the rates of gastric ulcers and gastritis were significantly higher for the 67 HCV-infected patients with H. pylori infection (34.3% and 77.6%) than for the 158 HCV-noninfected controls with H. pylori infection (15.2% and 57.6%). Treatment to eradicate H. pylori had a signifi cantly higher success rate for HCV-infected patients (61 of 67, 91.0%) than for HCV-noninfected controls (115 of 158, 72.8%). Conclusions: The markedly high H. pylori eradication rate observed in this study shows that eradication of H. pylori holds promise for the improvement of the long-term health condition of patients with chronic HCV infection. (Gut Liver 2011;5:447-453)