http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
CT 영상을 이용한 악골 골수염의 경조직 변화에 관한 연구
안창현,최보람,허경회,이원진,이삼선,최순철 대한구강악안면방사선학회 2009 Imaging Science in Dentistry Vol.39 No.3
Purpose : To assess the clinical findings and hard tissue changes of osteomyelitis of the jaws using computed tomographic (CT) image analysis. Materials and Methods : We reviewed and interpreted the CT images of 163 patients (64 males and 99 females, age range from 10 to 87 years) who visited the Seoul National University Dental Hospital from April 23, 2006 to December 31, 2008 and were diagnosed as osteomyelitis of the jaws through clinical, radiologic, and histopathologic examination. Each CT findings was investigated for frequency, correlation with age and gender. Results : Of the 163 patients, 31 (19.0%) were affected on the maxilla, 135 (82.8%) were affected on the mandible, and 3 (1.8%) were affected on the both jaws simultaneously. The mean age of the patients who were affected on the maxilla was 61.0 years and that of the patients who were affected on the mandible was 56.2 years. On the maxilla, the most frequent site of disease was the posterior area (83.9%) and on the mandible, mandibular body (83.0%), followed by angle (48.1%), ramus (38.5%), condyle (13.3%), incisal area (9.6%), and coronoid process (3.0%). Among the 31 maxillary osteomyelitis, defect in the trabecular bone was observed in 28 (90.3%), osteosclerosis 20 (64.5%), defect in the cortical bone 27 (87.1%), sequestrum 17 (54.8%), and periosteal reaction 2 (6.5%). Among the 135 mandibular osteomyelitis, defect in the trabecular bone was observed in 100 (74.1%), osteosclerosis 104 (77.0%), defect in the cortical bone 116 (85.9%), sequestrum 36 (26.7%), and periosteal reaction 67 (49.6%). Conclusion : Of our cases, the maxillary osteomyelitis was visibly observed more frequently in females than males. The incidence is the highest in seventies (28.8%) and the lowest in teens (3.1%). The osteomyelitis of the jaws was observed more frequently in males than females before the age of 50, and observed more frequently in females after the age of 50. The most noticeable point was that the sequestrum was observed more often on maxillary osteomyelitis and the periosteal reaction was observed more often on mandibular osteomyelitis. (Korean J Oral Maxillofac Radiol 2009; 39 : 163-8)
지용화,최보람,허경회,안창현,이삼선 대한구강악안면방사선학회 2009 Imaging Science in Dentistry Vol.39 No.2
The present study reports a case of inverted papilloma of the nasal cavity and infiltrating into the maxillary sinus. Inverted papilloma is an uncommon and locally aggressive benign tumor of the sinonasal region. The patient, 51-year-old male, presented with unilateral nasal obstruction and periodic swelling on the palate without pain. Enhanced CT scan revealed a heterogeneously enhancing solid mass in the nasal cavity and infiltrating into the right maxillary sinus, as well as an incidental, secondarily infected residual cyst m the periapical area of the right maxillary canine. The sinonasal mass was revealed as an inverted papilloma on histopathologic examination.
디지털 측방두부규격방사선사진과 MDCT의 3차원 재구성 영상을 이용한 합성측방두부규격방사선사진의 계측치 비교 및 머리 위치가 미치는 효과
김미자,최보람,허경회,이원진,허민석,이삼선,최순철 대한구강악안면방사선학회 2009 Imaging Science in Dentistry Vol.39 No.3
Purpose : To investigate the reproducibilities and compare the measurements in digital and MDCT-synthesized cephalometric radiograph, and to investigate the effect of head position on the measurement during imaging with MDCT. Materials and Methods : Twenty-two dry skulls (combined with mandible) were used in this study. Conventional digital cephalometric radiograph was taken in standard position, and MDCT was taken in standard position and two rotated position (10°left rotation and 10°right tilting). MDCT data were imported in OnDemand?? and lateral cephalometric radiograph were synthesized from 3D virtual models. Two types of rotated MDCT data were synthesized with default mode and with corrected mode using both ear rods. For all six images, sixteen angular and eleven linear measurements were made in V-Ceph?? three times. Reproducibility of measurements was assessed using repeated measures ANOVA and ICC. Linear and angular measurements were compared between digital and five MDCTsynthesized images by Student t-test. Results : All measurements in six types of cephalometric radiograph were not statistically different under ICC examination. Measurements were not different between digital and MDCT-synthesized images (P> .05). Measurements in MDCT-synthesized image in 10°left rotation or 10°right tilting position showed possibility of difference from digital image in some measurements, and possibility of improvement via realignment of head position using both ear rods. Conclusion : MDCT-synthesized cephalometric radiograph can substitute conventional cephalometric radiograph. The error on head position during imaging with MDCT have possibility that can produce measurement errors with MDCT-synthesized image, and these position error can be corrected by realignment of the head position using both ear rods. (Korean J Oral Maxillofac Radiol 2009; 39 : 133-47)
Clinical image quality evaluation for panoramic radiography in Korean dental clinics
Bo-Ram Choi,Da-Hye Choi,Kyung Hoe Huh,Won-Jin Yi,Min-Suk Heo,Soon-Chul Choi,Kwang-Hak Bae,Sam-Sun Lee 대한구강악안면방사선학회 2012 Imaging Science in Dentistry Vol.42 No.3
Purpose: The purpose of this study was to investigate the level of clinical image quality of panoramic radiographs and to analyze the parameters that influence the overall image quality. Materials and Methods: Korean dental clinics were asked to provide three randomly selected panoramic radiographs. An oral and maxillofacial radiology specialist evaluated those images using our self-developed Clinical Image Quality Evaluation Chart. Three evaluators classified the overall image quality of the panoramic radiographs and evaluated the causes of imaging errors. Results: A total of 297 panoramic radiographs were collected from 99 dental hospitals and clinics. The mean of the scores according to the Clinical Image Quality Evaluation Chart was 79.9. In the classification of the overall image quality, 17 images were deemed ‘optimal for obtaining diagnostic information,’ 153 were ‘adequate for diagnosis,’ 107 were ‘poor but diagnosable,’ and nine were ‘unrecognizable and too poor for diagnosis’. The results of the analysis of the causes of the errors in all the images are as follows: 139 errors in the positioning, 135 in the processing, 50 from the radiographic unit, and 13 due to anatomic abnormality. Conclusion: Panoramic radiographs taken at local dental clinics generally have a normal or higher-level image quality. Principal factors affecting image quality were positioning of the patient and image density, sharpness, and contrast. Therefore, when images are taken, the patient position should be adjusted with great care. Also, standardizing objective criteria of image density, sharpness, and contrast is required to evaluate image quality effectively.