http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
장주희,권영세,김복기,손병관,이지은,임대현,김순기,김준미,강성길 연세대학교의과대학 2008 Yonsei medical journal Vol.49 No.6
We report a case of acute severe hepatitis with Mycoplasma pneumoniae (M. pneumoniae) infection and transient depression of multiple coagulation factors. A 5-year-old boy, previously healthy, was admitted with pneumonia. M. pneumoniae infection was confirmed by serology testing. Liver enzymes were elevated on admission without any past medical history. After treatment with azithromycin for 3 days, pneumonia improved, but the hepatitis was acutely aggravated. Partial thromboplastin time (PTT) was prolonged and depression of multiple coagulation factors developed. Liver biopsy revealed features consistent with acute hepatitis. A week later, liver enzymes were nearly normalized spontaneously. Normalization of prolonged PTT and coagulation factors were also observed several months later. This may be the first case of transient depression of multiple coagulation factors associated with M. pneumoniae infection.
UV detecting properties of ZnO nanorod grown on cylindrical PET monofilament
장주희,한정인,엄태훈 한국공업화학회 2016 한국공업화학회 연구논문 초록집 Vol.2016 No.1
ZnO seed 용액과 growth 용액을 이용하여 ZnO를 합성하고 이를 PET 단일섬유에 코팅하여 UV를 감지하는 장치를 제작하였다. 각각 다른 UV 강도에 따른 I-t 그래프를 측정하였고 이를 바탕으로 응답시간과 conductance를 측정하였다. UV 강도에 따라 전류, 저항, 응답시간 등이 어떻게 변화하는지 나타내었다.
Water endurance of Ni resistive temperature sensor fabricated on cylindrical PET single fiber
장주희,한정인,엄태훈 한국공업화학회 2016 한국공업화학회 연구논문 초록집 Vol.2016 No.1
Wearable device에 적용 가능한 저항식 온도 센서를 제작하였다. 원통형 PET 단일섬유에 니켈 박막층을 증착하여 온도에 따라 저항이 증가하는 원리를 이용하였다. Wearable device에 적용이 용이하기 위해 유연성과 물에 대한 내구성을 평가하였다. 제작된 온도 센서를 물에 넣고 건조하는 방법을 반복하여 실험을 하기 전 TCR (Temperature Coefficient of Resistance)와 실험 후 TCR을 비교하여 분석하였다.
Effect of concentration of ZnO growth solution in hydrothermal synthesis on cylindrical PET fiber
장주희,한정인,엄태훈 한국공업화학회 2016 한국공업화학회 연구논문 초록집 Vol.2016 No.1
ZnO는 넓은 band gap(3.3eV), 큰 exciton binding energy(60 meV) 같은 특성으로 인해 최근에 활발한 연구가 진행중이다. ZnO를 합성하는 방법에는 여러가지가 있는데 본 연구에서는 수열 합성법을 이용하였다. ZnO를 seed 용액과 growth 용액의 비율을 달리하여 ZnO를 성장시키고 그 특성을 평가하였다. FESEM을 사용하여 표면 상태를 측정하고 XRD와 XPS 분석을 통하여 성장 상태를 분석하였다.
Influences of the ratio between pre-monomer and agent of PDMS to Pressure Sensing Property
장주희,한정인 한국공업화학회 2016 한국공업화학회 연구논문 초록집 Vol.2016 No.1
The technology of wearable computing device has been developed fast. Especially, IoT (internet of things) technology would be cooperated with this device well, for example, wearable humidity sensor or temperature sensor or UV sensor was fabricated on fiber previously. Also PDMS is an elastic solid, structures made from PDMS are low cost, quick to fabricate, transparent, biocompatible, and flexible. In this work, we fabricated cylindrical capacitor which could detect pressure change. This cylindrical device was consisted of four layers, two nickel thin films for inner and outer electrodes and Polydimethylsiloxane (PDMS) layer with polyvinyl alcohol (PVA) at middle of that for dielectric material. The nickel thin film was deposited by RF magnetron sputtering and PDMS layer was dip-coated after mixing pre-monomer with agent differently. The ratio of pre-monomer and agent was utilized diversely. And then capacitance was measured by using HP 4284A.
Fabrication of CuO Humidity Sensor coated on Cylinderical PET Mono Filament
장주희,한정인,박영민 한국공업화학회 2016 한국공업화학회 연구논문 초록집 Vol.2016 No.1
최근 들어 스마트 디바이스에 관한 관심이 높아짐에 따라 전자 섬유를 이용한 센서에도 많은 관심이 집중되고 있다. 그 중에서도 습도 센서는 우리의 삶에 있어서 가장 밀접한 연관성을 지니고 있다. 습도센서는 CuO thin film를 sputtering process를 이용하여 제작 하였다. Sputtering 조건은 Ar flow rate, O<sub>2</sub> flow rate가 각각 15 sccm, 6 sccm이며 working pressure는 3.15 × 10-2 Torr, RF power는 200W로 10분간 sputtering을 진행 하였다. 습도는 30% 부터 90%까지 측정하였으며 각각의 습도에 대한 I-V 측정은 KEITHLEY 6517장비를 이용하여 측정 하였다.
장주희,한정인 한국공업화학회 2016 한국공업화학회 연구논문 초록집 Vol.2016 No.1
The recent decades, there is a thorough study would require a potential, promising activity materials into alternative electrode materials lithium-ion batteries (LIBs), specifically in hybrid electric vehicle is more and more widely used in the world. Olivine-structured, such as orthophosphates Li2MP2O7 (M=Mn,Fe,Co, and Ni) have been presented as potential for promoting to cathode material since its initial discovery in 1977, because of their good thermal stability and high voltages versus the Li+/Li couple when charging and discharging. Of course, it is also important to note that the Iron and nickel members of Olivier structured phosphates are generally good for the environment and low cost.
Esthetics Quantification of Zirconia Artificial Teeth
장주희,한정인,엄태훈 한국공업화학회 2016 한국공업화학회 연구논문 초록집 Vol.2016 No.1
지르코니아는 인공 치아에 사용되는 주재료로 현재 인공 치아 시장의 대부분을 차지하고 있다. 현재는 특별한 측정 방법이 없이 사람의 주관적인 판단으로 인공 치아의 색상과 밝기를 대조하여 심미 특성을 판단하고 있다. 하지만 본 연구에서는 치아의 색상, 밝기, 반사율 등을 휘도계를 이용하여 측정하고 이를 DB화 및 정량화를 하여 객관적인 수치를 나타냈다. 이러한 객관화된 데이터를 바탕으로 치과용 소결로 기술과 접목하면 사용이 편리해지고 심미 특성이 동일하게 객관화 되어 특성이 매우 우수해진다.