http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
나트륨 이온선택성 PVC Dibenzo-18-Crown-6 막전극에 관한 연구
윤영자 崇田大學校 1985 論文集 Vol.15 No.1
Sodium ion selective Dibenzo-18-Crown-6 membrane electrode was prepared by Dibenzo-18-Crown-6, n-butylphtalate, and polyvinyl chloride powder mixture in tetrahydrofuran medium. This membrane electrode has shown excellent linear potential response to sodium ion and potassium ion concentration range from 10?M to 10?M and 10?M. This membrane electrode could be used as an indicating electrode in the potentiometric titration of single halide anion and mixture halide anion solutions with the standard solution of silver nitrate.
윤영자,박인옥,정기주 이화여자대학교 사범대학 교육학과 1961 교육 연구 Vol.- No.18
이상으로 대체적인 경향만을 조사했으나 불충분한 것을 면치 못하며 부그러울 뿐이다. 우리가 느끼는 바로는 학생들의 과목외에 배우고 싶어하는 과목을 과외로 가르칠수 있도록 기회를 주었으면 하고 학생들이 싫어하는 과목에 대하여 좀 더 흥미를 끌수 있는 방법으로 하여 결핍없는 지식과 활동에 완전을 하는데 노력했으면 좋겠다.
저온상압에서 합성된 Na,TPA-ZSM-5의 결정화에 관한 Solid State $^{27}Al$ 및 $^{29}Si$ MAS NMR 분광학적 고찰
윤영자,하재목,Yun, Young Ja,Ha, Jae Mok 대한화학회 1996 대한화학회지 Vol.40 No.10
저온상압법에 의해 Si/Al의 비가 100정도되는 ZSM-5를 합성하였으며 시간 경과에 따른 결정화과정을 $^{27}Al$ 및 $^{29}Si$ MAS NMR spectea 및 FT-IR로 고찰하였다. 저온상압 하에서 합성한 결과 초기 반응물질 및 성분비에 따라 화학적 이동은 기종의 연구와는 다른 경향을 보였으나 반응이 진행됨에 따라 최종 생성물의 화학적 이동은 전형적이 ZSM-5 영역에서 나타나고 있음을 확인하였다. 그리고 국부결함은 소성에 의해 제거되었으며 최종생성물의 XRD 및 SEM의 결과에서도 합성된 물질이 ZSM-5임을 확인하였다. Using low temperature and atmospheric pressure method, we synthesized Na, TPA-ZSM-5 with Si/Al ratio of about 100. We employed 27Al and 29Si MAS NMR spectroscopy and FT-IR to investigate the crystallization process as a function of time. The chemical shift depends on the initial composition of reactants and changes during the course of synthesis different from those reported by others earlier. However, the chemical shift of our final product showed in the range of typical ZSM-5. And the defect site was removed by the calcine. From XRD and SEM data, the formation of ZSM-5 was also confirmed.
윤영자 대한영상의학회 1984 대한영상의학회지 Vol.20 No.3
Direct coronal CT scans of the body have been carried out in 78 cases of the thoracic and abdnominal diseases. The results are as follows; 1. Among total 78 cases of the direct coronal CT. 2. Direct coronal CT scan most accurately detected retroperitoneal diseases, especially renal diseases. 3. In comparison with multiplanar reformating (MPR) image, direct coronal CT of the body has three advantages: (a) improved image quality : (b) improved definition of the coronal anatomy : (C) shorter examination time. 4. Direct coronal CT has advantages in evaluation of the mass nature and relationship with other organs. 5. Disadvantages or limitations of the direct coronal CT are as follows: increased radiation exposure and insufficient positioning for disabled patients. 6. In our experience, direct coronal CT is considered ad helpful method for presurgical evaluation and therapeutic management of various diseases, especially gross tumor of the retroperitoneum.