유형태(H. T. Yu),임태우(T. W. Lim),양찬경(C. K. Yang),류시형(S. H. Ryu),이성철(S. C. Lee),최승일(S. I. Choi),김상일(S. I. Kim),이영춘(Y. C. Lee) 한국정밀공학회 2006 한국정밀공학회 학술발표대회 논문집 Vol.2006 No.5월
The automatic inspection system is developed for the formed end part of automotive fuel pipe. The developed system has functions of outer diameter and formed end length measurement by LVDT(linear variable differential transformer) together with burr cleaning of automotive fuel pipe. The measured data are managed and controlled in real time by embedded SPC(statistical process control) program. The system is composed of mechanical part, electronic part and developed software system. These three parts operate automatically by mutual communication with each other. The developed system showed good results in finding inferior goods and efficiency improvement of the fuel pipe production line. It also eliminated the unreliable manual inspection processes and improved the confidence of product quality.
X-CARE 사용시 안구와 유방의 선량 감소 효과와 영상 평가에 관한 연구
오현식(Hyun Sik Oh),유형태(Hyung Tae Yoo),남윤철(Yoon Cheul Nam),김문찬(Moon Chan Kim),한동균(Dong Kyoon Han) 대한CT영상기술학회 2011 대한CT영상기술학회지 Vol.13 No.2
목적 감수성이 높은 표재성 장기인 안구와 유방의 선량감소 효과가 있는 X-CARE를 대상으로 두부와 흉부 검사 시 선량감소효과와 영상의 화질을 평가하여 보고하고자 한다. 대상 및 방법 CT 장비는 Siemens사의 Dual Source Somatom Definition Flash를 사용하였으며, organ dose 측정을 위해 Female Alderson Radiation Therapy Phantom과 유리선량계를 사용하였다. 두부 검사시 안구의 표면, 두부 전면부, 후면부에서 측정하였으며, X-CARE를 사용하지 않을 때와 사용했을 때의 선량을 각각 2번씩 측정하여 비교하였다. 흉부 검사시에는 유방과 흉부의 전면부, 중간부, 후면부의 선량을 AEC 모드의 사용여부에 따라서 X-CARE를 사용하지 않을때와 사용했을 때의 선량을 각각 2번 측정하여 비교하였다. 영상의 화질 평가는 ACR 팬텀을 사용하여 얻어진 영상을 ImageJ 분석 프로그램을 이용하여 직선성과 균일도를 평가하였다. 통계분석은 Minicab을 통해 2 Sample t-test로 분석하여 선량의 유의성을 확인하였다. 결과 두부 검사시 안구의 표면선량과 전면부 선량은 X-CARE의 사용전에 비해 사용후에는 35.2%, 14.6% 감소하였으며, 후면부에서는 9.1% 증가하였다. 흉부 검사에서 AEC를 적용하지 않으면서 X-CARE를 사용하면 사용 전에 비해 유방, 흉부 전면부, 중간부의 선량은 각각 30.0%, 11.3%, 3.8% 감소하여 유의한 선량감소를 타나냈다(p<0.05). 그러나 후면부에서는 13.6%로 증가하였다. AEC를 적용하면서 X-CARE를 사용하면 사용전에 비해 유방, 흉부 전면부의 선량이 27.8%, 11.0% 감소하여 유의한 감소 효과를 나타냈다(p < 0.05). 그러나 흉부중간부와 후면부에서는 각각 1.4%, 4.5% 증가하였다. 영상의 화질 평가는 직선성과 균일도 모두 ACR에서 정한 기준 범위에 포함되었다. 결론 X-CARE는 영상의 화질 변화 없이 감수성이 높은 표재성 장기인 안구와 유방에 선량 감소 효과를 나타낼 수 있는 방법으로 여성과 소아 검사에 있어서 적극적인 사용을 권고한다. I. Purpose To measure absorbing dose reduction and evaluate image quality by glass dosimeter to eyeball and breast which are high sensitive superficial organs when examining head and chest using X-CARE. II. Meterial and Methods Dual Source Somatom Definition Flash of Siemens Company was usedfor the CT scan and Female Alderson Radiation Therapy Phantom and glass dosimeter were used for organ dose evaluation. ACR phantom was used for image quality evaluation and program Minicab was used for statistics analysis. For organ dose evaluation, we compared eyeball skin dose during head exam and the dose examined two times whether using X-CARE or not to the frontal and occipital partial of the head. For chest exam, we compared the dose examined two times whether using X-CARE or not to breast dose and the frontal, middle, rear side of chest following to use AEC mode or not. Using image j analysis program, we evaluated the linearity and uniformity the image gotten by ACR phantom. Through out Minitab, we confirmed dose significance by analyzing 2 Sample r-test. III. Result For dose evaluation of head exam, eyeball skin dose and the frontal dose show 35.2%, 14.6% reduction comparing before use and after use, the rear side shows 9.1% growth. To not apply AEC of chest exam, after use of X-CARE show the breast front, middle, rear dose were decreased 30.0%, 11.3%, 3.8% and the rear side increased 13.56% comparing before use. To apply AEC,however, after use of X-CARE show the breast dose and the frontal dose shows 27.8%, 11.0% reduction and the middle and rear side shows 1.4%, 4.5% growth. For image quality evaluation, it contains the standard range of ACR phantom The dose evaluated at the head shows all small differences(p < 0.05) and the breast dose and the front and rear side show small differences(p < 0.05), the middle partial shows no small differences(p > 0. 05) without the use of chest AEC. When the breast does and the frontal dose show small differences(p < 0.05) with the use of AEC, the middle and rear side show no small differences(p > 0. 05). IV. Conclusions X-CARE is the good way to show to eyeball and breast which are high sensitive superficial organswithout the image changing I think.