http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
PSCAD/EMTDC를 이용한 계통연계형 PV시스템의 mppt제어를 위한 fuzzy제어기 설계에 관한 연구
김규한(Kyu-Han Kim),김형수(Hyung-Su Kim),이상훈(Sang-Hun Lee),이화석(Hwa-Seok Lee),박준호(June-Ho Park) 대한전기학회 2010 대한전기학회 학술대회 논문집 Vol.2010 No.11
This paper proposes a method of maximum power point tracking (MPPT) using fuzzy logic control for grid-connected photovoltaic systems(PV). First for the purpose of comparison and because of its proven and good performances, the incremental conductance (IncCond) technique is briefly introduced. A fuzzy logic controller (FLC) based MPPT is then proposed which has shown better performances compared to the IncCond MPPT based approach. Modeling and Simulation in grid-connected PV system results are provided for both controllers under same atmospheric condition based PSCAD/EMTDC. The fuzzy logic MPPT controller is then simulated and evaluated, which has shown better performances.
김규,권기철 경성대학교 산업개발연구소 2013 산업혁신연구 Vol.29 No.4
이 논문은 전력법 2003을 계기로 시행된 인도의 여러 전력시장 개혁 조치들이 제대로 그 성과를 발휘하고 있는지를 분석하는 것을 목적으로 한다. 이를 위해 전력법 2003의 제정과 2008년 전력거래소의 출범 이후 형성된 인도의 단기 도매전력시장의 구조와 시장성과를 분석한다. 전력법 2003 및 전력거래소 출범 이후에도 인도의 전력 부족은 해소되지 않고 있다. 2012-13년에 인도 전체로 8.7%의 전력부족률을 기록했다. 단기 전력거래는 계속 증가해왔다. 2011-12년에 총발전량의 10.8%를 차지했다. 이것은 단기 수급 상황에 대한 인도 전력시장의 대응능력이 커졌음을 의미한다. 2009년 3월부터 2013년 3월 사이에 집중률과 HHI는 경향적으로 하락해왔다. 특히 HHI는 2011년 5월 이후 추세 상으로 과점시장 판단 기준 0.18보다 낮은 수준으로 떨어졌다. 단기 도매전력시장의 가격은 초기에 변동성이 매우 컸으나, 2010년 7월 이후 안정적인 수준을 유지하고 있다. NTPC의 연차 자료를 이용하여 산출한 가격-비용 마크업은 2004-05년부터 2007-08년 사이에는 상승하다가 그 이후에는 하락해왔다. 이 자료만으로는 가격-비용 마크업이 하락 추세에 있다고 말하기 어렵다. 그리고 NTPC의 마크업은 다른 나라의 사례와 비교하면 매우 높은 수준이다. 인도 도매전력시장의 경쟁을 활성화하고 성과를 높이기 위해서는, 발전업체 분할, 적정 송전 능력의 확보, 가격상한제 유지, 수급 격차 감축이 필요하다.
무극 금은 광상에 대한 유체포유물 및 안정동위원소 분석연구
김규한,김옥준,장원선,Kim, Kyu-Han,Kim, Ok-Joon,Chang, Weon-Sun 대한자원환경지질학회 1990 자원환경지질 Vol.23 No.1
A couple of Au-Ag-bearing epithermal quartz veins of Cretaceous(87.9Ma) in age are developed in the Cretaceous(112Ma) granodiorite batholith which was emplaced in Mesozoic Baegyari sedimentary formation. Au minerals consist mostly of electrum with a 54.2-61.9 wt% Au and are closely associated with sulfide minerals including pyrite, chalcopyrite, pyrrhotite, galena and sphalerite. Homogenization temperatures of fluid inclusions in quartz, fluorite and calcite are $196-368^{\circ}C$ (avg. $240^{\circ}C$), $74-176^{\circ}C$ (avg. $115^{\circ}C$) and $75-200^{\circ}C$ (avg. $119^{\circ}C$) respectively. Sulfur isotopic compositions( +5- +8‰) of ore sulfides indicate a deep-seated sulfur origin. Oxygen isotope compositions of different stages of quartz vary from +5.6 to +9.3‰ and calculated ${\delta}^{18}O$ values of ore fluid at $250^{\circ}C$ range from -3.2 to +0.4‰, reflecting an isotopically evolved ore fluid mixed with a $^{18}O$ depleted meteoric water under the variable mixing ratios between hydrothermal and meteoric waters. Isotopic data of calcite minerals support the above conclusions.
김규,서지원,조익성,최의영,홍그루,하종원,임세중,심지영 연세대학교의과대학 2022 Yonsei medical journal Vol.63 No.9
Purpose: The fusion of early (E) and late diastolic filling (A) on mitral inflow Doppler, even in the absence of tachycardia, is oftenfound during assessment of left ventricular (LV) diastolic function. We evaluated the echocardiographic characteristics and clini-cal implications of premature E-A fusion of uncertain cause in the absence of tachycardia. Materials and Methods: We identified 1014 subjects who showed E-A fusion and normal LV ejection fraction (LVEF) between Janu-ary 2019 and June 2021 at two tertiary hospitals. Among these, 105 (10.4%) subjects showed premature E-A fusion at heart rates lessthan 100 beats per minute (bpm). The conventional echocardiographic parameters and LV global longitudinal strain (GLS) werecompared with 1:1 age-, sex-, and heart rate-matched controls without E-A fusion. Results: The premature E-A fusion group had a heart rate of 96.4±3.7 bpm. Only 4 (3.8%) subjects were classified as having LV di-astolic dysfunction according to current guidelines. The group showed prolonged isovolumic relaxation time (107.2±25.3 msecvs. 61.6±15.6 msec, p<0.001), increased Tei index (0.76±0.19 vs. 0.48±0.10, p<0.001), lower LVEF (63.8±7.0% vs. 67.3±5.6%,p<0.001) and lower absolute LV GLS (|LV GLS|) (17.0±4.2% vs. 19.7±3.3%, p<0.001) than controls. As the E-A fusion occurred atlower heart rate, the |LV GLS| was also lower (p for trend=0.002). Conclusion: Premature E-A fusion at heart rates less than 100 bpm is associated with subclinical LV dysfunction. Time-based in-dices and LV GLS are helpful for evaluating this easily overlooked population.