RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 음성지원유무
        • 원문제공처
          펼치기
        • 등재정보
          펼치기
        • 학술지명
          펼치기
        • 주제분류
          펼치기
        • 발행연도
          펼치기
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        수종 치과재료의 제I급 와동에서의 변연 누출에 관한 실험적 연구

        이선희,손흥규,최형준 大韓小兒齒科學會 1996 大韓小兒齒科學會誌 Vol.23 No.1

        Microleakage is a problem of all filling materials of losted teeth structure and is clinically undetectable. Because marginal leakage may be responsible for pulp irritation, pulp inflammation, necrosis and recurrent caries, it is essential to prevent and control it. For the evaluations of microleakage of various class I filling materials, 175 extracted teeth were filled with amalgam, light curing composite resin, glass inomer cement, IRM and Fermit-N. After thermocycling, speciemens were placed in 1% methylene blue dye solution for 24 hours in an incubator set 37℃. The teeth were sectioned at filling body center and margin and degree of dye penetration was observed with a stereomicroscope. The following results were obtained. 1. Light cured composite resin has the excellent results and microleakage is increased in the order of amalgam, IRM, Fermit-N, glass ionomer cement.(SAS-6.0 system) and there was a statistically significancy in marginal leakage for each filling materials.(Kruskal-Wallis analysis, P<0.05) 2. Microleakage of the center and margin was statistically insignificant (Mann-Whitney analysis P<0.05) 3. There was less microleakage for amalgam than light cured composite resin but was statistically insignificant (Mann-Whitney analysis, P<0.05) and also showed less marginal leakage for Fermit-N compared to glass ionomer cement but also was statistically insignificant. (Mann-Whitney analysis, P<0.05).

      • KCI등재

        저항소자를 이용한 휴대형 Real-time PCR 기기용히터 제작

        최형준,김정태,구치완 한국전기전자학회 2019 전기전자학회논문지 Vol.23 No.1

        A heater in a portable real-time polymerase chain reaction(PCR) system is one of the important factors for controllingthe PCR thermocycle precisely. Since heaters are integrated on a small-sized PCR chip for rapid heating and fabricatedby semiconductor processes, the cost of producing PCR chips is high. Here, we propose to use chip resistors as aninexpensive and accurate temperature control method. The temperature distribution was simulated using one or two chipresistors on a real-time PCR chip and the PCR chip with uniform temperature distribution was fabricated. Thetemperature rise and fall rates were 18°C/s and 3°C/s, respectively. 바이오샘플의 DNA를 대량 증폭할 수 있는 휴대형 실시간 중합효소연쇄반응(Real-time PCR) 기기에서 히터는 PCR 반응온도를 제어하기 위한 중요한 요소 중의 하나이다. 보통 빠른 히팅을 위해 소형 PCR 칩에 집적화되어 있고, 반도체 공정을이용하여 박막형태로 제작되어 PCR 칩 제작 단가가 높은 편이다. 따라서 본 연구에서는 값싸고 온도제어를 정확히 할 수 있는 히터로 칩 저항을 사용하는 것을 제안한다. 칩 저항을 사용한 히터는 구조가 단순하고 제작이 쉽다는 장점이 있다. 2.54× 2.54 cm² 크기의 실시간 PCR 칩 위에 칩 저항을 1개 또는 2개를 사용했을 때 온도분포를 시뮬레이션 하였고, 고른 온도분포를 갖는 PCR 칩을 제작했다. 또한 효율적인 PCR 칩 냉각을 위해 소형 fan이 내장된 하우징을 설계하였고, 3D 프린터로제작했다. 온도제어는 마이크로프로세서를 이용한 PID제어법(Proportional-Integral-Differential control)을 적용했다. 온도상승비와 하강비는 각각 18℃/s, 3℃/s이며, 각 PCR 반응 단계의 유지 시간을 30초로 하였을 때, 한 사이클은 약 2.66분이 걸렸고, 35 사이클은 약 93 분 내로 진행할 수 있었다.

      • KCI등재

        Usefulness of Early Extracorporeal Shock Wave Lithotripsy in Colic Patients with Ureteral Stones

        최형준,정진희,배정범,조민철,이해원,이광수 대한비뇨의학회 2012 Investigative and Clinical Urology Vol.53 No.12

        Purpose: To compare efficacy and safety between early extracorporeal shock wave lithotripsy (eESWL) and deferred ESWL (dESWL) in colic patients with ureteral stones and to investigate whether eESWL can play a critical role in improving treatment outcomes. Materials and Methods: A total of 279 patients who underwent ESWL for single radio-opaque ureteral stones of 5 to 20 mm in size were included in this retrospective study. The patients were categorized into two groups according to the time between the onset of colic and ESWL: eESWL (<48 hours, n=153) and dESWL (≥48 hours,n=126). Success was defined as stone-free status as shown on a plain radiograph within 1 month of the first session. Results: For all patients, the success rate in the eESWL group was significantly higher than that in the dESWL group. The eESWL group required significantly fewer ESWL sessions and less time to achieve stone-free status than did the dESWL group. For 241patients with stones <10 mm, all treatment outcomes in the former group were superior to those in the latter group, but not for 38 patients with stones sized 10 to 20 mm. The superiority of eESWL over dESWL in the treatment outcomes was more pronounced for proximal ureteral stones than for mid-to-distal ureteral stones. Post-ESWL complication rates were comparable between the two groups. In the multivariate analysis,smaller stone size and a time to ESWL of <48 hours were independent predictors of success. Conclusions: Our data suggest that eESWL in colic patients with ureteral stones is an effective and safe treatment with accelerated stone clearance. Purpose: To compare efficacy and safety between early extracorporeal shock wave lithotripsy (eESWL) and deferred ESWL (dESWL) in colic patients with ureteral stones and to investigate whether eESWL can play a critical role in improving treatment outcomes. Materials and Methods: A total of 279 patients who underwent ESWL for single radio-opaque ureteral stones of 5 to 20 mm in size were included in this retrospective study. The patients were categorized into two groups according to the time between the onset of colic and ESWL: eESWL (<48 hours, n=153) and dESWL (≥48 hours,n=126). Success was defined as stone-free status as shown on a plain radiograph within 1 month of the first session. Results: For all patients, the success rate in the eESWL group was significantly higher than that in the dESWL group. The eESWL group required significantly fewer ESWL sessions and less time to achieve stone-free status than did the dESWL group. For 241patients with stones <10 mm, all treatment outcomes in the former group were superior to those in the latter group, but not for 38 patients with stones sized 10 to 20 mm. The superiority of eESWL over dESWL in the treatment outcomes was more pronounced for proximal ureteral stones than for mid-to-distal ureteral stones. Post-ESWL complication rates were comparable between the two groups. In the multivariate analysis,smaller stone size and a time to ESWL of <48 hours were independent predictors of success. Conclusions: Our data suggest that eESWL in colic patients with ureteral stones is an effective and safe treatment with accelerated stone clearance.

      • RFID 기술의 동향과 개발전망

        최형준,문승진 한국지능정보시스템학회 2011 한국지능정보시스템학회 학술대회논문집 Vol.2011 No.5

        2004년도의 IT839운동으로부터 시작된 IT성장으로 인해 RFID의 중요성은 미래의 정보기술시장을 선도하기에 충분한 기술로 자리 잡히고 있다. 특히 지속적으로 성장하고 있는 스마트 폰과 결합된 모바일 RFID기술 시스템은 지식경제부를 중심으로 하여 다양한 기업들이 기술 표준화 및 구체적으로 추진되고 있는 서비스 발굴을 진행 중에 있다. 실생활에 큰 파급을 가져온 스마트 폰과의 결합은 더욱 편리한 세상이 되는 걸음에 가속을 붙여줄 것이다. 이와 같이 현재 RFID 기술의 동향과 더불어 휴대폰뿐 아니라 국내 다양한 분야에서 쓰이는 RFID의 기술력과 개발방향에 대해 전망한다.

      • KCI등재

        체격 및 신체조성 측정 자료의 결측값 대체 방법 비교

        최형준,이윤수 한국체육측정평가학회 2019 한국체육측정평가학회지 Vol.21 No.4

        The purpose of this study was to compare between actual observed values and estimated values using 4 difference methods for missing values imputation based on body measurement data and body composition data of Korean representatives athletes. The methods for missing values imputation in this study were using by mean, by median, by k-Nearest Neighbor functions, and by Multivariate Imputation by Chained Equation(MICE). The missing values were conducted into 5%, 10%, 15%, and 20% from the original dataset. And then, the actual observed values and the estimated by 4 different methods of missing values imputation were compared with RMSE(root mean squared error). The results of this study were as following belows. First of all, The lowest values of RMSE was found on the using with k-NN functions and it was not depending on the difference conditions of missing values ratio(such as 5%, 10%, 15%, and 20%). Also, the deviation of RMSE between the methods of missing values imputation was the fewest on the ‘weight’ variable, and was the greatest on the ‘bottom length’ variable. Secondly, the increasing rates of ratio of missing values from 5% to 20% influenced upon all methods of missing values imputation such as mean, median, k-NN and MICE. Additionally, the ‘weight’ variable has the greatest deviation of RMSE depending on the increasing ratio of missing values. Consequently, increasing numbers of further researches relevant to this study are required in the field of sports science and physical education in order to apply the missing values imputation efficiently. 이 연구는 국가대표 선수들의 체력 및 신체조성 자료에 대한 결측값을 대체하는 방법을 4가지로 구분하고 결측값비율에 따라 나타나는 실제 관찰 자료와의 차이를 통해 결측값 대체 결과를 비교하는데 목적을 두었다. 이 연구에서사용한 결측값 대체 방법은 평균, 중앙치, k-NN 최대근접이웃함수, 연쇄 방정식을 이용한 다중대체 방법이었으며, 기존 자료의 5%, 10%, 15%, 20%에 해당하는 자료를 무작위로 결측시킨 후, 실제 관찰값과 추정값을 비교하였다. 4가지 결측값 대체 방법의 결과 비교를 위하여 평균 제곱근 오차(RMSE: root mean squared error)를 사용하여 얻은결과는 다음과 같다. 첫째, 체력 및 신체조성 결측 자료에 대한 변수별 결측값 대체 결과, k-NN 최대근접이웃함수를이용한 결측값 대체 방법은 타 결측값 대체 방법에 비해서 결측값 비율에 관계없이 가장 낮은 평균 제곱근 오차를 나타냈다. 또한, 4가지 결측값 대체 방법의 평균 제곱근 오차에 대한 편차는 체중 변수에서 가장 높게 나타났으며, 하퇴위 변수에서 가장 낮게 나타났다. 둘째, 4가지 결측값 대체 방법에 의한 평균 제곱근 오차는 결측값의 비율이 5%, 10%, 15%, 20%로 증가함에 따라서 모두 증가하는 것으로 나타났다. 더불어 결측값의 비율이 증가함에 따라서 4가지결측값 대체 방법 간 평균 제곱근 오차의 편차가 가장 높은 변수는 체중 변수로 나타났다. 향후 다양한 체육 및 스포츠 자료의 특성에 맞는 효율적인 결측값 대체를 위하여 후속 연구가 지속적으로 이루어져야 한다고 사료된다.

      • 무기체계 특수공정 품질관리를 위한 수준평가 모델 연구

        최형준,최재호,박성제 한국품질경영학회 2020 한국품질경영학회 학술대회 Vol.2020 No.-

        군수품의 첨단화와 높은 기술수준 진화로 양산품질 중심에서 개발품질 중심으로 업무 중심축이 이동하고 있어 개발단계 품질관리 강화방안이 지속적으로 연구되고 있다. 본 연구에서는 개발단계에서 이루어지는 협력업체 특수공정 평가를 위한 과학적 모델을 개발하고 적용을 통해 효과성을 검증하고자 한다. 특수공정 평가 모델 및 수행방안 구축을 위하여 공정 생산성 및 인증서 관련 업체 품질수준 평가, 업체 수준 및 기대효과 제시를 통한 통합사업관리단 협업, 5M1E 기반 및 사례분석을 통한 점검표 개발, 업체 수준별 산출물 도출과 같이 4가지 위험요인을 식별하여 평가 모델에 적용하였다. 품질수준평가는 제출 산출물의 심층검토를 통해 정부기관 승인, 체계업체 기승인, 체계업체 주기심사, NADCAP 인증여부에 따라 4가지 경우(Case1~4)로 분류하여 품질수준(Quality Level)을 구분하였다. 특히, Case4의 경우 체계업체 최초심사를 수행한 업체로서 특수공정 평가 시 점검표를 활용한 정부 현장심사가 필요하다. 특수공정 평가모델은 특수공정수행업체 공정준비(Set-up)에서 협력업체, 체계개발주관업체, 통합사업관리단, 평가(승인)기관의 유기적인 검토/보완/승인 후 개발단계 품질이 확보된 제품이 생산되는 평가모델을 개발하였다. 평가모델 개발 검증을 위해 17개 업체 및 표면처리, 열처리 등 262개 특수공정을 대상으로 특수공정 평가모델을 적용하였다. Case4에 해당하는 67개 특수공정을 대상으로 16개 업체에 점검표를 활용하여 현장심사를 수행하였으며, 49건의 개선사항이 도출되었다. 단순 수치적 개선사항 분석결과로 5ME1 중 자제(Material)관리가 가장 미흡하였다. 본 연구를 통해 협력업체의 품질수준을 반영한 차등화된 평가모델을 적용하여 객관적 평가 및 효율적 검토를 바탕으로 완벽한 군수품 품질 확보에 활용하고자 한다.

      • 다층 퍼셉트론의 새로운 두 단계 학습 알고리즘

        최형준,이재욱 한국경영과학회 2003 한국경영과학회 학술대회논문집 Vol.- No.1

        본 논문에서는 다층 퍼셉트론의 학습을 위한 새로운 두 단계 학습방법을 제안하였다. 첫 번째 단계는 국소최적해로 빨리 수렴하기 위해 Levenberg-Marquardt 알고리즘을 이용한 국소 탐색 단계이다. 두 번째 단계는 첫 번째 단계에서 찾은 국소최적해가 원하는 수준에 미치지 못할 경우 새로운 국소최적해로 벗어나기 위한 선형탐색을 기반의 터널링 단계이다. 이 방법은 연결가중치 공간에서 전역최적해를 빠르게 찾을 수 있는 새로운 학습 방법을 제공한다. 4가지벤치마크 문제에 기존의 다층 퍼셉트론의 학습 알고리즘과 비교 실험을 통해, 제안된 알고리즘이 빠른 수렴 속도와 낮은 오차값을 가짐을 알 수 있었다.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼