RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 음성지원유무
        • 원문제공처
          펼치기
        • 등재정보
          펼치기
        • 학술지명
          펼치기
        • 주제분류
          펼치기
        • 발행연도
          펼치기
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재후보

        Continuous Wave of Condensation Technique으로 근관충전시 치근면 온도상승 분석

        김영주,황윤찬,김선호,황인남,최보영,정영진,정우남,오원만 大韓齒科保存學會 2003 Restorative Dentistry & Endodontics Vol.28 No.4

        This study was conducted to evaluate the temperature rise on the root surface while the root canal is being obturated using continuous wave of condensation technique. Maxillary central incisor was prepared for repeated canal obturation. Ten thermocouples (Omega Engineering Inc., Stanford, USA) were placed at 1mm increment from the anatomical root apex. The real temperature of Buchanan plugger was recorded before insertion into the root canal. The root canal was obturated with continuous wave of condensation technique as described by Buchanan and the root surface temperature was recorded during obturation at 150℃, 200℃, 250℃ and 300℃ temperature settings of System B HeatSource (Model 1005, Analytic technologies, Redmond, WA, USA). After completion of the temperature recording, the dentinal-cementum thickness at each sites was measured. The data were analyzed using one-way ANOVA followed by Scheffe's test and linear regression test. The results were as follows. 1. When the temperature was set at 150℃, 200℃, 250℃ and 300℃ on the digital display of System B HeatSource, the real temperature of the plugger at the 1mm point from the tip revealed 130.82±2.96℃ 158.00±5.26℃, 215.93±6.91℃ and 249.88±3.65℃ respectively. 2. The position of 8 mm from the anatomical apex showed the highest temperature increase at each temperature settings and it was significantly higher than those of other positions (p<0.01). The temperature rise was constantly increased toward coronal portion from apex of the root. 3. The maximum temperature increase on the root surface was 2.37±0.09℃ at 150℃ setting, 3.11±0.12℃ at 200℃ setting, 3.93±0.09℃ at 250℃ setting and 5.69±0.15℃ at 300℃ setting respectively. These results suggest that it be relatively kind to the supporting tissues of the root that the root canal is obturated using continuous wave of condensation technique at 150℃, 200℃, 250℃ and 300℃ temperature settings on digital temperature display of System B HeatSource.

      • Continuous Wave of Condensation Technique으로 근관충전시 치근면 온도상승 분석

        김영주,황윤찬,김선호,황인남,최보영,정영진,정우남,오원만 전남대학교 치의학연구소 2003 구강과학 Vol.15 No.4

        This study was conducted to evaluate safety to the supporting tissues of the root while the root canal is obturated using continuous wave of condensation technique. A extracted maxillary central incisor was prepared for repeated canal obturation. After conventional access opening, working length was then established to the point 1㎜ from anatomical root apex. The root canal was prepared with GT rotary Ni-Ti file (Dentsply Maillefer, Switzerland). Five thermocouples (Onega Engineering Inc., USA) were placed at 2㎜ increments on one side beginning 1㎜ from the anatomical root apex and the other five thermocouples at 2㎜ increments on the other side beginning 2㎜ from it. For obturation, a nonstandardized medium size gutta-percha cone and a ML Buchanan plugger (Analytic technologies, USA) were selected. After drying of root canal, AH 26 root canal sealer (Dentsply Detrey, Germany) was applied on the wall of the root canal. Baseline temperature was measured on the root surface. The ML size plugger was preheated for 2seconds and then the real temperature of it was recorded before insertion into the root canal. The root canal was obturated with continuous wave of condensation technique as described by Buchanan. The root surface temperature was recorded during obturation and it was performed ten times at each of the following temperature settings: 150℃, 200℃, 250℃ and 300℃. After completion of the temperature recording, the dentinal-cementum thickness at each sites where thermocouples were attached was measured. The data were analyzed using one-way ANOVA followed by Scheffe's test and linear regression test. The results were as follows. 1. When the temperature was set at 150℃, 200℃, 250℃ and 300℃ on the digital display of System B HeatSource, the real temperature of the plugger at the 1㎜ point from the tip revealed 130.82±2.96℃, 158.00±5.26℃, 215.92±6.91℃ and 249.88±3.65℃ respectively. 2. The position of 8 ㎜ from the anatomical apex showed the highest temperature increase at each temperature settings and it was significantly higher than those of other positions (p<0.01). The temperature rise was constantly increased toward coronal portion from apex of the root. 3. The maximum temperature increase on the root surface was 2.37±0.09℃ at 150℃ setting, 3.11±0.12℃ at 200℃ setting, 3.93± 0.09℃ at 250℃ setting and 5.69± 0.15℃ at 300℃ setting. These results suggest that it be relatively kind to the supporting tissues of the root that the root canal is obturated using continuous wave of condensation technique at 150℃, 200℃, 250℃ and 300℃ temperature settings on digital display of System B HeatSource.

      • KCI등재

        초·중·고등학교 학생, 학부모, 일반교사의 보건교육 요구

        윤순녕,김영임,최정명,조희순,김영희,박영남,오경순,이분옥,조선녀,조소영,한선희,하영미 韓國學校保健學會 2004 韓國學校保健學會誌 Vol.17 No.2

        Purpose : The purpose of this study was to identify needs of health education of the students, parents, general teachers, and health teacher of the elementary, middle, and high schools. Method : 279 schools of elementary, middle, and high school were sampled nonproportionally during the period from June 28 to July 26, 2004 . The data were collected by the questionnaire from 1,888 students, 1,876 parents, 1,695 general teachers, 279 health teachers. A frequency, % and χ2-test were used to analysis by SAS program. Result : 1. It showed that 98.1% of elementary school students, 92.3% of middle school students, 89.6% of high school students answered that they need health education. The most of students, parents, and general teachers had high interests in health education. 2. In the case of students, main causes of needs of health education was 'to prevent diseases or accidents''. But parents answered that it was 'to build up a healthier behavior'. General teachers answered that it was 'more effective systematic and continuous health education'. 3. Over 80% of students, parents, and general teachers about the question of who qualified person is to teach health education as a regular class responded that health teacher is available. Especially 93% of elementary school students answered like that. 4. The most of students, parents, and general teachers answered that health education in the classroom is favorable 1 to 2 hours per week. Conclusion : As results of the study , the majority of students, parents, general teachers agreed needs of health education. Therefore, on the basis of this study, systematic and continuous health education is necessary. Additionally the establishment of independent health subject is required certainly.

      • KCI등재

        초·중·고등학교 학생·학부모·일반교사의 보건교육 영역별 요구도와 보건교육

        윤순녕,김영임,최정명,조희순,김영희,박영남,오경순,이분옥,조선녀,조소영,한선희,하영미 韓國學校保健學會 2005 韓國學校保健學會誌 Vol.18 No.1

        Purpose: The purpose of this study was to identify the needs of health education in students, their parents and teachers in the elementary, middle and high schools and the current situation of health education class. Method: The subjects of this study were a total of 9450 persons including students, their parents and teachers from 279 schools throughout the country. They were selected through convenient sampling. Data were analyzed through x^(2)­test and ANOVA. Result: Students, their parents and teachers replied that 18 dimensions of health education class (DHEC) are necessary. The four DHEC - healthier life style, sex education, mental health and safety education - showed high educational needs in students, their parents, and teacher. High school students had higher educational need of 'symptom management for daily living' than elementary and middle school students. Students, their parents and teachers in elementary school had higher educational needs of 17 DHEC that those in middle and high school. The percentages of schools with health education class taught by health teachers were 99.2%, 75.5% and 66.0% respectively in elementary, middle and high schools. Health education was given mainly using physical education classes at elementary schools, and creative class hours at middle and high schools. In general, health education took 1-3 hours per week at elementary schools, and less than an hour at middle and high schools. Conclusion: Therefore, based on the results, systematic health education class should begin from elementary school to meet the need of health education in students, their parents and teachers, and further study should be made on the number of hours required and the amount of contents of 18 DHEC.

      • Thermocouple을 이용한 Buchanan Plugger 표면의 온도상승 분석

        조진숙,황윤찬,김선호,황인남,최보영,정영진,정우남,오원만 전남대학교 치의학연구소 2003 구강과학 Vol.15 No.4

        This study was performed to confirm the actual temperature rise on the surface of Buchanan plugger by evaluating the temperature rise on the surface of it, the peak temperature of pluggers of various size using thermocouple. The heat carrier system 'System B Heatsource' (Model 1005, Analytic Technologies, USA) and the Buchanan pluggers of F, FM, M and ML sizes are used for this study. The temperature was set to 200 which Dr. Buchanan's "Continuous wave of condensation" technique recommended on digital display and the power level on it was set to 10. The touch mode was used. Five thermocouples were placed in direct contact with the surface of each size of Buchanan's pluggers at 1 ㎜ increments from the tip to the 4 ㎜ length of shank. Each thermocouple was secured with cyanoacrylate adhesive and orthodontic resin block. The two wire leads of each thermocouple were connected to the appropriate channels of Data Logger. This was configured to simultaneously record input from the five thermocouples. The heat control spring was touched for 1, 2, 3, 4 and 5 seconds, and the temperature rise on the surface of the pluggers were measured at 1 sec intervals for more than 5 seconds with an accuracy of 0.01. Ten trials was determined for each plugger. The average of temperature rise and standard deviation was calculated for each size of plugger. The data were statistically analyzed by one-way ANOVA to determine their significance. The results as follows. 1. The position at which the temperature peaked was approximately at 1∼2㎜ far from the tip of Buchanan plugger (p<0.01). 2. The peak temperature was 215.25±2.28℃ in F plugger, 185.94±2.19℃ in FM plugger, 169.51±9.12℃ in M plugger, and 160.79±1.27℃ in ML plugger and the peak temperature was highest in F type and followed by, in descending order, FM type, M type. ML type showed the lowest peak temperature (p<0.01). This results suggest that the actual temperature on the surface of the pluggers does not correlate well with the temperature set on digital display. Heat concentrates around the tip. The larger plugger reveals lower temperature rise relatively.

      • Dependance of active layer diping concentration of threshold voltage for fully depleted SOI nMOSFET's

        오순영,조남인 선문대학교 첨단과학기술연구소 1996 첨단과학기술연구소 논문집 Vol.1 No.1

        완전공핍된 SOI nMOSFET를 SIMOX 웨이퍼 상에 구현하였으며 전기적인 특성을 조사하였다. 소자의 제작은 기존의 CMOS 공정기술을 사용하였다. SOI 기판의 실리콘 층의 두께는 back gate 전압을 인가하지 않았을때 소자동작시에 능동영역이 모두 공핍되기 위하여 100㎚ 이하로 하였다. 제작된 소자 의 threshold 전압은 능동영역의 불순물 농도의 변화에 의해 조정할 수 있었다. threshold 전압 측정 결과 는 이미 제안된 완전공핍된 SOI 모델에 의한 계산치와 거의 일치하였다. fully depleted SOI nMOSFETs have been implemented by the conventional device process using SIMOX wafer, and their electrical characteristics have been analyzed. The top silicon layer of the SOI was less than 100㎚ in order to maintain the full depletion during the device operation without the application of the back gate voltage. The threshold voltage of the FETs can be controlled by varying the impurity concentration of the active layer. The results of the threshold voltage measurements are in good agreement with the previously proposed fully-depleted SOI model by others.

      • KCI등재

        폐부종과 심정지가 발생한 페노바비탈 중독환자

        오동렬,이운정,박규남,김세경,김영민,이환,유은영,최경호,정시경 大韓應急醫學會 1999 대한응급의학회지 Vol.10 No.2

        Phenobarbital is a long-acting barbiturate causing generalized depression of neuronal activity in the brain. Its effect is primarily achieved through enhanced GABA-mediated synaptic inhibition. Its use as an antiepileptic agent was first described in 1912. Before the introduction of phenytoin, phenobarbital is used as sedative-hypnotics. It is used for the treatment of epilepsy and status epilepticus. All barbiturates, including phenobarbital, have a high potential for abuse. They were frequently used for suicide attempts in the past, but they have in large part been replaced by benzodiazepines. The onset of symptoms depends on the drug and the route of administration. Mild to moderate barbiturate intoxication resembles ethanol inebriation with slurred speech, ataxia, and lethargy. Severe acute barbiturate intoxication is life threatening. Early deaths are generally cardiovascular-related. Hypotension, shock, pulmonary edema, and cardiac arrest that occurs with large doses are caused by depression of central sympathetic tone and as well as by direct depression of cardiac contractility. The potentially fatal oral dose of phenobarbital is 6-10g. We describe an 23-year-old woman with pulmonary edema, and cardiac arrest ingestion of 18grams of phenobarbital. She was completely recovered by successful cardiopulmonary resuscitation and homoperfusion. We report a case with literature review.

      • 동적 재구성 가능한 모듈기반 신경망 프로세서의 설계 및 구현

        오남호,김영진,이현수 경희-다반 ASIC 설계교육센터 2004 경희-다반 ASIC센터 논문집 Vol.5 No.-

        본 논문에서는 신경망 알고리즘의 데이터 의존관계에 따라 연산방식이 동적으로 재구성되는 신경망 프로세서를 제안한다. 기존의 신경망 소프트웨어 시뮬레이터는 많은 학습시간을 필요로 하기 때문에 실시간 응용에서 요구하는 성능을 만족시키기가 어려웠으며 하드웨어적인 구현의 필요성이 증대하였다. 신경망 하프웨어 중에 ERNA(Erpansible and Reconfigurable Neural Network Architecture)는 모듈구조를 이용하여 확장성이 뛰어났지만 SIMD로 처리되었기 떼문애 신경망에 존재하는 데이터의 병렬성을 효과적으로 처리하지 못하였다. 따라서 신경망의 뉴런 및 레이어간에 나타나는 데이터의 연길관계를 이용하여 알고리즘의 병렬성을 극대화할 수 있는 재구성 가능한 구조를 제안한다. 신경망 알고리즘의 변형이나 시스템의 구조적인 변경이 필요하지 않기 때문에 다양한 신경망 모델에 적용이 가능하였으며 모듈구조를 사용함으로써 신경망의 크기에 대한 유연한 대응이 가능하였다.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼