RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 음성지원유무
        • 원문제공처
          펼치기
        • 등재정보
          펼치기
        • 학술지명
          펼치기
        • 주제분류
          펼치기
        • 발행연도
          펼치기
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • SCIEKCI등재

        Event Mean Concentrations (EMCs) and First Flush Characteristics of Runoff from a Public Park in Korea

        Jung, Jae-Woon,Park, Ha-Na,Yoon, Kwang-Sik,Choi, Dong-Ho,Lim, Byung-Jin The Korean Society for Applied Biological Chemistr 2013 Applied Biological Chemistry (Appl Biol Chem) Vol.56 No.6

        Characteristics of non-point source (NPS) pollution runoff from a public park in Gwangju, Korea were investigated. Results exhibited the highest pollutant concentrations at the start of the rainfall events due to their build-up and wash off processes. The average event mean concentrations (EMCs) were 27.8, 7.2, 56.3, 7.5, and 0.84 mg/L (range: 4.2-54.8 mg/L) for COD, (0.5-20.8 mg/L) for TOC, (22.3-138.4) for SS, (1.4-18.5 mg/L) for T-N, and (0.17-2.02 mg/L) for T-P, respectively. The study site presented a strong first flush effect for most rainfall events. However, no first flush effect was observed in rainfall events with small rainfall factors (e.g. intensity, amount, and runoff depth). On the other hand, the ratios of total pollution loads discharged by the first 20% of runoff volume were 32% for COD, 34% for TOC, 36% for SS, 42% for T-N, and 50% for T-P. Especially, $MFF_{20}$ (mass first flush) values of T-N and T-P were larger than those of other pollutants (COD, TOC, SS), indicating that T-N and T-P are easily transported by stormwater runoff from the public park. First flush management of T-N and T-P, therefore, is required for efficient water quality management of the public park.

      • 설악산 국립공원의 어류분포

        장민호,조가익,하진용,정광석,박성배,주기재 한국어류학회 2002 韓國魚類學會誌 Vol.14 No.4

        설악산 국립공원지역 산간계류의 17개 지점에서 2000년 6월부터 2001년 6월까지 어류상 및 이화학적 요인을 계절별로 총 4회에 걸쳐 분석하였다. 모든 조사지점은 1~3차의 하천으로 비교적 물리·화학적 교란이 적었으며 하천폭은 5~30 m 정도였다. 채집된 어류는 총 18과 42종 2,557개체였고, Cyprinidae는 16종으로 84.7%의 상대풍부도를 나타냈으며, Gobiidae 4종, 5.0?의 상대풍부도를 보였다. Cyprinidae는 전체 채입종의 37.2%를 나타냈다. 우점종은 Zacco temminck로 10개 지점에서 738개체가 채집되어 28.9%의 상대풍부도를 나타냈으며, 아우점종은 Rhynchocypris kumkangensis와 Z. platypus로 각각 4개 지점 648개체(25.3%)와 7개 지점 344개체(13.5%)로 나타났다. 한국고유종(Korean endemic species)은 모두 4과 11종 781개체로 30.5%의 상대풍부도를 나타냈으며, 고유화 빈도는 25.6%로 한국의 평균 고유화 빈도와 유사하게 나타났다. 본 조사에서 외래어는 채집되지 않았다. 국립공원 내에 서식하는 어류의 다양성 유지와 회복을 위해서는 공원 내는 물론 경계지역 하천의 체계적인 관리가 요구된다. The fish fauna of mountain streams in the Seorak National Park area was investigated from June 2000 to June 2001 (4 times). All 17 sites were relatively undisturbed 1st to 3rd order streams. A total of 2,557 individuals were collected and classified into 17 families and 43 species. Cyprinidae accounted for 37.2% (16 species) of the total fish species and 84.7% (2,165 ind.) of the total abundance. Subdominant families were Gobiidae (4 species, 5.0%) and Balitoridae (3 species, 3.4%). Zacco temmincki (RA 28.9%, 10 sites) dominated. Subdominant species were Rhynchocypris kumkangensis (25.3%, 4 sites) and Zacco platypus (13.5%, 7 sites). Eleven of the species are endemic to Korea (4 families, 30.5%). Exotic species were not collected in this survey. Fish diversity was higher in streams around the boundary area than in the national park. Therefore, management of streams in the boundary area to protect the fish biodiversity can be efficiently conducted. Habitat degradation should be reduced for the conservation and restoration of fish diversity.

      • KCI등재

        ACCase 저해 제초제 cyhalofop-butyl에 대한 경남지방 수집종 피의 저항성

        원종찬,원옥재,하준,임일빈,강광식,변종영,박기웅,이증주,Won, Jong Chan,Won, Ok Jae,Ha, Jun,Im, Il-Bin,Kang, Kwang Sik,Pyon, Jong Yeong,Park, Kee Woong,Lee, Jeung Joo 한국잡초학회한국잔디학회 2018 Weed & Turfgrass Science Vol.7 No.2

        Repeated use of ACCase inhibiting herbicides for a long time has resulted in increases of resistant Echinochloa oryzicola populations in paddy fields in middle west area of Korea. This study aims to investigate current status of herbicide resistant E. oryzicola in Gyeongsangnam-do, in which there is less information about herbicide resistance. For resistance frequency and dose-response study, seeds from 100 individual plants of E. oryzicola in Gyeongsangnam-do were collected and tested with cyhalofop-butyl. Seven percent of plants from Gyeongsangnam-do was resistant at a recommended rate of cyhalofop-butyl. $GR_{50}$ values (herbicide rates required to reduce plant growth 50%) for one representative resistant populations and five susceptible populations were $738g\;a.i.\;ha^{-1}$ and 66-234 (average 147)$g\;a.i.\;ha^{-1}$, respectively, indicating average 5 times difference in resistance. Although lower rate of frequency of herbicide resistance in Gyeongsangnam-do than in Jeollabuk-do, increases of herbicide resistance are expected in this area because of increases of direct seeded rice fields and increases of dependence on a specific herbicide. Therefore, it is necessary to monitor herbicide resistance regularly and conduct integrated herbicide resistance management in this area. 경남지역 제초제 저항성 피의 발생현황과 저항성 정도를 알아보기 위하여 벼 재배 논에서 100개체의 피 종자를 수집하여 ACCase 저해제인 cyhalofop-butyl에 대한 약량반응 실험을 수행한 결과, 수집한 피의 7%가 저항성으로 조사되었다. 선발된 감수성 5개체의 $GR_{50}$값은 평균 $147g\;a.i.\;ha^{-1}$로 나타났고, 함양 지역의 저항성 개체의 $GR_{50}$값은 $738g\;a.i.\;ha^{-1}$ 로 R/S (ratio of resistance to sensitivity)값은 5.01배로 나타났다. 현재 경남지역에서의 저항성 피의 발생 수준은 낮은 것으로 나타났지만, 저항성 피의 확산을 지연시키거나 막기 위해서는 주기적인 저항성 피의 모니터링과 체계적인 저항성 잡초 관리방안을 마련하여 수행할 필요가 있다.

      • 폐기물 관리와 향후 대책

        박광하,김한수,권영두 7개 국립대학교 환경연구 논문집 공동발행 위원회 2001 환경연구논문집 Vol.1 No.1

        오늘날 우리가 직면한 환경문제 중 하나인 폐기물에 대한 기본 개념을 이해하고, 우리 나라 폐기물의 발생현황을 살펴보며, 여러 가지 폐기물을 처리하기 위한 방법과 폐기물을 자원화 하는 방법에 대해 고찰하였다. 폐기물은 발생단계에서 원천적으로 줄이는 노력이 무엇보다 중요하며, 또한 발생된 폐기물에 대해 효과적으로 대처하기 위해서는 경제성을 고려한 기술개발을 통하여 저렴하고 안전하게 폐기물을 처리해야 한다. 또한 현대 사회는 대량생산과 대량 소비를 하는 사회경제체제에서 비롯되었기 때문에 이를 효과적으로 극복하기 위해서는 대량생산, 대량소비 체제를 지속 가능한 자원순환형 사회경제 체제로 전환시켜 폐기물 발생을 방지하는 방향으로 나아가야 할 것이다.

      • SCOPUSKCI등재

        아크릴아미드 고정 구멍갈파래에 의한 중금속 Cd(Ⅱ), Pb(Ⅱ) 이온의 흡착특성 (Ⅰ)-Column법

        박광하,권영두,정영진,장은경 한국공업화학회 2004 공업화학 Vol.15 No.1

        본 연구에서는 동해안 해조류인 구멍갈파래를 아크릴아미드에 고정하여, Cd(Ⅱ) 및 Pb(Ⅱ) 중금속 이온의 흡착 특성을 살펴보았다. 수순한 Ulva pertusa 및 Si-Ulva pertusa 흡착제보다는 아크릴아미드에 고정화된 Ulva pertusa의 경우 많은 양의 중금속이 흡착되었으며, Pb(Ⅱ) 이온이 Cu(Ⅱ) 이온보다 더 잘 흡착되는 것으로 나타났다. 흡착제의 농도가 작은 경우 중금속 이온의 흡착량은 pH에 큰 영향이 없었으나, 흡착제의 농도가 클 경우 중금속 이온의 흡착량은 pH에 큰 영향을 받았다. pH에 따른 중금속 이온의 흡착량은 pH 10.5 > 8.5 > 7.0 > 5.5 > 3.5 순으로 나타났다. 아크릴아미드에 고정화된 Ulva pertusa의 단위 질량에 대해 Cd(Ⅱ) 및 Pb(Ⅱ) 이온의 최대 흡착량은 각각 최대 8.73 ㎎과 13.20 ㎎으로 나타났다. 또한 Cd(Ⅱ) 및 Pb(Ⅱ) 이온의 회수율은 pH에 따라 다소 차이가 있었으나, 각각 61.3~75.5% 및 61.4~54.1%로 나타났다. 중금속 이온의 회수에 있어서 산성 조건이 알칼리성 조건보다 효율적이었으며, 본 실험에 의한 중금속 이온의 흡착 특성은 Freundlich 흡착 특성과 잘 일치하는 것으로 나타났다. Adsoprtion characteristics of Cd(II) and Pb(II: heavy metal ions onto the Acrylamide-immobilized Ulva pertusa, and algae of the eastern coastal area. was examined in this work. Much amounts of heavy metal ions were adsorbed onto the Acrylamide-immobilized than either bare Ulva pertusa or Si-Ulva pertusa. It was also observed that Pb(II) was more readily adsorbed on the algae that Cu(II). The adsorption amounts of heavy metal ions showed no great dependence on the pH value at low adsorbent concentration, but those were high dependent on pH value at high adsorbent concentration. The adsorption amounts of heavy metal ions were in the following order; pH 10.5 > 8.5 > 7.0 > 5.5 > 3.5. The maximum adsorption amounts of Cd(II) and PB(II) onto Ig of Acrylamide-immobilized Ulva pertusa were 8.73 mg and 13.20 mg, respectively. It was found that recovery yields of Cd(II) and Pb(II) ions were in the range of 61.3∼75.5% and 61.4∼54.1% depending on the pH level. In the heavy metal recovery, acidic condition was more efficient that alkaline condition. The adsorption behavior of these heavy metal ions was well matched with the Freundlich adsorption isotherm.

      • CROSS 공법을 이용한 폐수의 생물학적 처리에 관한 연구

        박광하,심재도,권영두,강동수,김인호,정태명,황갑성 7개 국립대학교 환경연구 논문집 공동발행 위원회 2003 공업기술연구 Vol.3 No.-

        This study aims to develop using a continuous removal of organic and settling solid(CROSS) to increase the efficiency of aeration system for wastewater treatment. To solve many problems of the conventional activated-sludge process, authors suggested a new CROSS model in conjunction with aeration systems in 1996. This system is characterized by utilizing an intensive aeration pipe with inlets at the lower portion and outlets at the higher portion in an aeration tank. Through the experiments on CROSS process, the average removal efficiences of BOD, COD_(Mn), SS, T-N and T-P were showed 98.8%, 93.9%, 98.0%, 71.3% and 49.8%. The average DO (Dissolved-Oxygen) concentration was constantly maintained at 8.0 mg/L by the intensive aeration which was accompanied by rapid reduction of BOD. Degradation of the organic matters in sewage then continued for the whole aeration period. The process demonstrated that it was very adaptive without seeding and returning the sludge. Compared to the activated sludge system, the system was very flexible for the continuous flow treatment. This preliminary assessment showed that the porous media in CROSS reactor is viable for the sewage treatment, since the porous media under the intensive aeration achieves acceptable effluent quality.

      • 아크릴아미드 고정 구멍갈파래에 의한 중금속 Cu(Ⅱ), Zn(Ⅱ) 이온의 흡착특성-Column법

        박광하,권영두,안중혁,김준범 7개 국립대학교 환경연구 논문집 공동발행 위원회 2004 공업기술연구 Vol.4 No.-

        Adsoprtion characteristics of Cu(II) and Zn(II) heavy metal ions onto the Acrylamide-immobilized Ulva pertusa, a living algae of the castern coastal area, was examined in this work. Much amounts of heavy metal ions were adsorbed onto the Acrylamide-immobilized Ulva pertusa than the bare Ulva pertusa. It was also observed that Zu(II) was more readily adsorbed on the algae than Cu(II). The adsorption, but those were high dependent on pH value at high adsorbent concentration. The adsorption amounts of heavy metal ions were in the following order; pH 10.5>8.5>7.0>5.5>3.5. The maximun adsorption amounts of Cu(II) and Zu(II) onto 1g of Acrylamide-immobilized Uiva pertusa were 7.6㎎ and 8.1㎎, respectively. It was found that recovery yields of Cu(II) and Zn(II) ions were in the range of 36.1-64.8% and 32.1-63.8% depending on the pH level. In the heavy metal ions was well matched with the Freundlich adsorption isotherm.

      • 영동지역 주요 3개 하천의 수질실태 및 관리에 관한 연구

        박광하,민선홍,최봉종,전방욱 강릉대학교동해안지역연구소 1994 東海岸硏究 Vol.5 No.1

        영동지방의 주요 3개 하천의 수질을 조사하고 QUAL-2E 모델을 적용하여 보았다. 강릉남대천은 각 수질항목에서 시기별, 정점별로 큰 차이를 보였으며, 일반적으로 상류의 수질은 하류로 갈수록 생활오수의 유입으로 수질이 악화되는 전형적인 양상을 나타내었다. 양양남대천은 강릉남대천 및 삼척오십천에 비하여 시기별 변이폭이 좁았으며 각 정점별의 수질도 양호한 것으로 나타났다. 삼척오십천은 시기별보다는 정점별 수질차이가 크게 나타났으며 오염된 상류의 수질이 자정작용에 의하여 개선되다가 다시 생활오수의 유입으로 인하여 악화되는 특이한 양상을 보였다. 모델링 결과 하천의 유속, 유량등의 실측 자료가 부족함에도 불구하고 강릉남대천과 양양남대천은 실측치와 예상치가 높은 상관관계를 나타내었다. 또한 이 모델을 사용하여 강릉남대천의 수질예측을 시도하였다. The water quality was monitored and QUAL-2E modelling was applied in three main stream of Youngdong area. Kangnung Namdaecheon was shown to be a typical stream that the downstream water quality was worse than in the upperstream. Water quality of Yangyang Namdaecheon was better than that of Kangnung Namdaecheon and Samchuk Osipcheon. The spatial variation of water quality was greater than the temporal variation in Samchuk Osipcheon: the polluted upperstream water got better in the midstream, but got worse gain in the downstream. Despite of the lack of suitable measurement data, Kangnung Namdaecheon and Ynagyang Namdaecheon showed good relationship between measured and obtained data: however Samchuk Osipcheon, which had many point sources and much pollution load, showed poor relationship. Based on this model, future water quality of Kangnung Namdaecheon was prospected.

      • ENTITY-RELATIONSHIP MODEL을 기초로한 COBOL 자료구조의 변화

        박영배,류광하 명지대학교 공학기술연구소 1987 공학기술연구소 논문집 Vol.2 No.-

        Recently the development of application field for Data Base, the existing FMS's, has become to transform its model to DBMS. As a part of these processes, we could find the way how general file can be applicable in Data Base areas. This paper aims to introduce a changing process from widely used COBOL Data Structure in FMS to conceptual schema E-R Type, and to show the representation method of processing in Entity - Relationship Model.

      • 탄성 의치상 이장재의 캔디다 알비칸스 부착도에 관한 실험적 연구

        하일수,조주온,이상돈,송광엽,박찬운 全北大學校 齒醫學硏究所 1992 전북치대논문집 Vol.10 No.1

        The purpose of this study is to compare the response of four commercially available soft denture lining materials to the growth of C. albicans in vitro. Twelve samples of each soft lining materials were made to a uniform size and volume(15×5×4㎜) and sterilized using ethylene oxide. The samples were individually placed in culture tubes containing 5㎖ of sterile SDB(sabouraud dextrose broth dehydrated) and 0.1㎕ of activated C. albicans(ATCC 10231). The culture tubes had been incubated in incubator at 37℃. Three samples of each material had been tested at 3, 21, 35 and 56 days to determine the number of adherent cells of C. albicans on their surfaces and the number of nonadherent cells in the broth associated with each samples. The data have been analyzed by ANOVA and Scheffe test. The results have been obtained as follows : 1. In growth patterns of C. albicans within soft lining materials, Molloplast-B and K-33 were significantly higher(p<0.01) compared with Coe-Soft, but there was no significant difference between Coe-Soft, Coe Super-Soft and Mollosil(p>0.05). 2. Molloplast-B showed significantly higher(p<0.01) amounts of C. albicans adhering to its surface than other materials under experimental conditions. 3. Generally, adherence was significantly increased until 5 weeks, and after then showed decreased pattern in all materials(p<0.01). 4. The C. albicans was able to penetrate the inner portion of all samples. Coe-Soft showed most amounts of invaded C. albicans, followed in order by Mollosil, Molloplast-B, and Coe Super-Soft.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼