FRP로 보강된 R/C 보의 휨내력 향상효과에 관한 실험연구
하상수,이용택,이리형 대한건축학회 1999 대한건축학회 학술발표대회 논문집 - 계획계/구조계 Vol.19 No.2
The purpose of this study is to evaluate the structural performance of the new reinforcement material, which has been developed by REFORM system. The carbon fiber sheet is susceptible to fire and brings the concern for the integration. The new reinforcement material was developed to overcome these problems of the carbon fiber sheet. The experiment was planned to evaluate the effect of reinforcement and integration for the new reinforcement material. The theoretic values of test specimens, which are being built, are compared with the experimental values of carbon fiber sheet and the expected effects are commented in the appendix. The experimental values of the specimens will lie compared with the theoretic values after the experiment.
아라미드섬유와 유리섬유로 혼합된 하이브리드 FRP 플레이트로 보강된 RC 보의 휨 보강 성능
하상수 대한건축학회지회연합회 2012 대한건축학회연합논문집 Vol.14 No.4
본 연구의 목적은 하이브리드 FRP(Fiber Reinforced Polymer) 플레이트로 보강된 철근 콘크리트 보의 휨 보강 효과를 파악하기 위한 것이다. 본 연구에 사용된 하이브리드 FRP 플레이트는 아라미드섬유와 유리섬유를 1:9로 혼합하고, 섬유와 에폭시를 7:3으로 혼합하여 제작한 보강재이다. 탄소 FRP 플레이트 또는 탄소섬유가 포함되어 있는 하이브리드 FRP 플레이트는 기존의 기하철 구조물이나 한국전기공사와 같이 전기를 사용하는 구조물을 보강하는데 한계가 있다. 그러나, 아라미드섬유와 유리섬유를 혼합한 하이브리드 FRP 플레이트는 비전도성이기 때문에 전기를 사용하는 구조물을 보강하는데 제한이 없다. 또한, 아라미드섬유와 유리섬유를 혼합하여 제작한 하이브리드 FRP 플레이트는 경제성 및 구조성능 측면에서 기존에 사용되어 온 FRP 플레이트보다 우수하다. 하이브리드 FRP 플레이트로 보강된 휨 부재의 휨 성능효과를 파악하기 위하여 7개의 제작하였다. FRP 플레이트 종류, 앵커형태, 그리고 에폭시 유무 등을 주요 실험변수로 하였다. 실험결과, FRP 플레이트로 보강한 모든 실험체가 보강하지 않은 실험체보다 우수한 구조성능을 나타내었고, 기존에 사용되어 온 FRP 플레이트로 보강한 실험체에 비해 아라미드섬유와 유리섬유를 혼합한 하이브리드 FRP 플레이트로 보강한 실험체가 우수한 휨성능을 나타내었다.
무연 솔더가 적용된 자동차 전장부품 접합부의 열적.기계적 신뢰성 평가
하상수,김종웅,채종혁,문원철,홍태환,유충식,문정훈,정승부,Ha, Sang-Su,Kim, Jong-Woong,Chae, Jong-Hyuck,Moon, Won-Chul,Hong, Tae-Hwan,Yoo, Choong-Sik,Moon, Jeong-Hoon,Jung, Seung-Boo 대한용접접합학회 2006 대한용접·접합학회지 Vol.24 No.6
This study was focused on the evaluation of the thermo-mechanical board-level reliability of Pb-bearing and Pb-free surface mount assemblies. The composition of Pb-bearing solder was a typical Sn-37Pb and that of Pb-free solder used in this study was a representative Sn-3.0Ag-0.5Cu in mass %. Thermal shock test was chosen for the reliability evaluation of the solder joints. Typical $Cu_6Sn_5$ intermetallic compound (IMC) layer was formed between both solders and Cu lead frame at the as-reflowed state, while a layer of $Cu_3Sn$ was additionally formed between the $Cu_6Sn_5$ and Cu lead frame during the thermal shock testing. Thickness of the IMC layers increased with increasing thermal shock cycles, and this is very similar result with that of isothermal aging study of solder joints. Shear test of the multi layer ceramic capacitor(MLCC) joints was also performed to investigate the degradation of mechanical bonding strength of solder joints during the thermal shock testing. Failure mode of the joints after shear testing revealed that the degradation was mainly due to the excessive growth of the IMC layers during the thermal shock testing.
뇌동맥류 수술시 일시적 근위부 뇌혈류 차단술이 예후에 미치는 영향에 관한 고찰
하상수,김형동 대한신경외과학회 1995 Journal of Korean neurosurgical society Vol.24 No.11
The author analyzed the postoperative results in 96 patients who underwent temporary clipping during cerebral aneurysm surgery from July, 1990 to April, 1995 1) The overall outcome were as follows : excellent (55.2%), good(21.9%), poor(16.7%), dead(6.3%) and its results were relatively similar to those of the patients who did not have the temporary clipping. 2) The patients were divided into 4 groups according to the site of the temporary clip application. The safe durations of temporary clipping were as follows : In the 1) anterior cerebral artery clipping group, 5 minutes for Hunt-Hess grade 1 & 2 patients and 2 minutes and 30 seconds for Hunt-Hess grade 3 & 4 patients ; In the 2) middle cerebral artery clipping group, 5 minutes ; In the 3) internal carotid artery clipping group, 5 minutes in Hunt-Hess grade 1 & 2 and 2 minutes for Hunt-Hess grade 3 & 4 ; The only one patient in the 4) basilar artery clipping group showed excellent outcome after 3 minutes of temporary clipping. Therefore, we concluded that the temporary clipping technique would be very useful to dissect the aneurysmal neck, to prevent and control the premature rupture without influencing the outcome. Furthermore, use of the cerebral protective agent, intraoperative cerebral blood flow monitoring and avoidance of excessive and prolonged hypotension during cerebral aneurysm surgery might be very helpful for preventing the celebral ischemia and increasing the safety duration of the temporary clipping.
겹침이음된 GFRP 보강근과 이형철근이 2단 배근된 휨 부재의 구조적 거동 특성
하상수 대한건축학회지회연합회 2016 대한건축학회연합논문집 Vol.18 No.4
본 연구의 목적은 겹침이음된 GFRP 보강근과 이형철근이 2단으로 배근된 휨부재의 구조적 거동특성을 파악하는 것이다. GFRP 보강근은 부식성, 경량, 전도등과 같은 많은 재료적인 장점을 가지고 있다. 그러나 GFRP 보강근은 항복점 없이 취성파괴로 인해 철근대용으로 사용하기가 쉽지 않다. 이형철근과 GFRP 보강근을 혼용한 휨 부재는 두 보강재료의 장점으로 인하여 우수한 구조적 성능을 보일 것으로 판단된다. 이형철근과 GFRP 보강근을 혼용한 휨부재의 구조적 거동을 파악하기 위하여 겹침이음길이와 보강근양을 주요변수로 하여 5개의 실험체를 계획하였다. 실험결과로서 첫째, 이형철근과 GFRP 보강근을 혼용한 모든 실험체는 이중선형거동을 보였다. 첫 번째 선형구간은 이형철근과 GFRP 보강근의 탄성에 의해 나타난 것이고, 두 번째 선형 구간은 GFRP 보강근의 탄성구간과 이형철근의 항복구간에 의해 나타난 것이다. 둘째 겹침이음된 GFRP 보강근이 파괴된 이후 2단에 배근된 철근이 하중을 부담함으로써 연성거동을 유지하여 결과적으로 GFRP 보강근과 이형철근을 사용한 부재가 이형철근만 배근된 RC 부재에 비해 우수한 성능을 보여주었다. The objective of the present study is to understand the characteristics of the structural behavior of flexural members with lap-spliced glass fiber-reinforced polymer (GFRP) bars at upper layer and deformed steel bars at lower layer. A GFRP bar has many advantages such as corrosiveness, light weight, and conduction. However, it is not easy to use GFRP bars instead of steel reinforcement due to brittle failure of GFRP bars. In this study, deformed bars and GFRP bars are used together for the advantages of the both materials, such as corrosion prevention and ductile behavior. It is expected that the flexural member with both GFRP and deformed bars shows good structural performance due to the aforementioned advantages of each reinforcement. Five specimens were tested to investigate the structural behavior of the members with the two different reinforcements. The main variables were lap splice length and amount of reinforcement. As a result of the experiment, all specimens with GFRP and deformed bars indicated bi-linear behavior, where the first linear part was due to the elastic portion of both reinforcements and the second one was caused by steel yielding and the elastic portion of GFRP bars. In addition, after GFRP bars failed, deformed bars at the lower layer contributed to the ductility of the specimen. Therefore, it was found that using both GFRP bars and deformed bars significantly improved structural performance when compared with reinforced concrete members with steel bars only.