RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
          펼치기
        • 등재정보
        • 학술지명
          펼치기
        • 주제분류
          펼치기
        • 발행연도
          펼치기
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        도시 생활폐기물 소각 바닥재를 혼합한 시멘트 고화체의 강도 특성

        윤중만,김태형,송영석 한국자원공학회 2008 한국자원공학회지 Vol.45 No.3

        In order to recycle the incineration bottom ash generated from municipal solid waste as a construction material, a series of uniaxial compression tests were carried out according to the mixing ratio of bottom ash, the curing temperature, the water-cement ratio, the mixing ratio of EPS and the curing time. As the results of tests, the water content of the hardened cement mortar keeps constant independent of curing time. Also, the water content is increased with increasing the mixing ratio of bottom ash, the water-cement ratio, and the mixing ratio of EPS. The unit weight of the hardened cement mortar is decreased with increasing the mixing ratio of bottom ash and the mixing ratio of EPS. The compression strength of the hardened cement mortar is decreased with increasing the mixing ratio of bottom ash. The compression strength of the hardened cement mortar cured at 30±2℃ and 40±2℃ is bigger than that of the cement mortar cured at normal temperature (20±2℃). However, the compression strength of the hardened cement mortar cured at 30±2℃ is bigger than that of the cement mortar cured at 40±2℃. The compression strength is increased at the range from 0.55 to 0.6 of water-cement ratio, and then the compression strength is decreased over 0.65 of water-cement ratio. Meanwhile, the compression strength of the hardened cement mortar is decreased with increasing the mixing ratio of EPS. The compression strength cured 28 days in each mixing ratio is ranged from 87 kg/cm2 to 220 kg/cm2. These strengths are satisfied with the standard value of compression strength (80kg/cm2) of sidewalk blocks.

      • KCI등재

        PHC 매입말뚝의 설계효율과 지지력 특성 사례분석

        윤중만,여규권,김홍연,최용규 한국지반신소재학회 2019 한국지반신소재학회 논문집 Vol.18 No.3

        본 연구에서는 건축기초에 적용된 매입 PHC말뚝의 설계사례를 분석하였다. 전반적인 말뚝길이는 최대 35m 이내에서 다양하나, 지지층 조건에 따른 평균 길이는 17.0∼18.9m로 큰 차이가 없었다. 지지층 소켓길이는 전체의 약 58%가 시방기준 최소길이인 1m에 따라 설계되었고, 최대 5m까지 설계되었다. 설계효율은 그 편차가 매우 크나 평균 약 70%로서 통상 알려진 범위와일치하였다. 설계효율이 낮은 용도는 주로 설계하중이 적은 저층건물이나 놀이기구 기초 등으로 나타났다. 풍화암 지지층에서설계하중은 설계를 지배하는 지반 허용지지력의 65∼97%, 허용지지력에 대한 말뚝 허용축하중의 비는 36∼115%로 광범위하게 분포하므로 설계효율과 함께 최적화 노력이 요구된다. 반면, 연・경암 지지층의 허용지지력은 대부분 말뚝 허용축하중의90% 내외로 매우 균등했다. 설계 허용지지력은 선단지지력이 평균 75% 이상을 차지하였으나, 현장재하시험 연구결과를 보면초기항타 조건에서는 선단지지력이 지배적이며, 재항타 조건에서는 선단지지력이 최소 25%에 불과한 경우도 있었다. 따라서, 설계시 산정된 허용지지력은 시공 초기조건만을 반영하는 것이며, 시간이 경과할수록 말뚝 주면부로의 하중전이가 증가하고, 일부는 시험시 타격에너지 부족으로 선단지지력의 확인이 이루어지지 못한다고 볼 수 있다. 균질한 지반으로 가정했을 때근입비가 증가할수록 허용축하중이 감소하는 경향이 있었고, 이와 유사하게 지반의 허용지지력도 감소하는 경향을 보여, 큰설계하중으로 초고강도 말뚝을 적용할 경우 지반의 지지력을 최대한 활용할 수 있음을 알 수 있었다. In this study, it was analyzed the cases of bored PHC piles designed for the building foundations. The overall length of the piles varies within a maximum of 35 m. However, the average length was 17.0 to 18.9 m depending on the kind of the bedrock, with no significant difference. The socket length entered into the bedrock was designed with approximately 58% of the whole piles being 1m, the minimum length of the specification, and up to 5m. Although the range in design efficiency was very large, on average it was about 70%, consistent with the usual known extent. Applications with low design efficiency were mainly shown on the foundation of low-rise buildings or rides with low design load. On the weathered rock, the design load, which governs the design result was widely distributed at 65 to 97% of allowable bearing capacity of ground. The ratio of allowable axial load of piles to allowable bearing capacity of ground is also widely distributed between 36 and 115%, so optimization efforts are required along with design efficiency. On the other hand, the allowable bearing capacity on the soft or hard rock was highly equal, mostly within 90% of the allowable axial load of piles. In the design, the end bearing resistance averaged over 75% of the allowable bearing capacity. However, the results of the dynamic pile load test show that the end bearing resistance was predominant under the E.O.I.D conditions, and in some cases, the end bearing resistance was at least 25% under the restrike conditions.

      • KCI등재
      • KCI등재

        바닥소각재에 포함된 중금속에 대한 용출특성 분석

        윤중만,김태형,송영석 한국자원공학회 2006 한국자원공학회지 Vol.43 No.6

        In order to analyze the change of leaching concentrations of heavy metals in before and after hardening with cement and to investigate the leaching mitigation effect of heavy metals, a series of leaching tests were performed for the raw bottom ash and the bottom ash hardened with cement. The bottom ash was mainly composed of Al, Si, S, Cl and Ca, and Ca occupies 40% of the entire bottom ash. The heavy metals such as Cd, Cu, Cr, Pb, Zn, Fe, and As were leached from the bottom ash, but the leaching concentrations of these heavy metals were less than the Korea standard value of waste management. With the exception of Cd, the heavy metals such as Cu, Cr, Pb, As and so on were leached from the bottom ash hardened with cement. The leaching concentrations of heavy metals in the bottom ash hardened with cement were smaller than those in the raw bottom ash. From experiment results, it can be concluded that the heavy metals in the bottom ash were fixated and stabilized by cement components. 본 연구에서는 바닥소각재와 시멘트로 고화처리된 바닥소각재에 대하여 용출시험을 실시하여 시멘트 고화처리 전후의 중금속 용출량의 변화를 분석하고, 시멘트 고화처리에 따른 중금속 용출 저감효과를 조사하였다. 바닥소각재는 주로 Al, Si, S, Cl 및 Ca로 구성되어 있으며, Ca성분이 차지하는 양이 전체의 약 40%에 해당하는 것으로 나타났다. 바닥소각재에는 Cd, Cu, Cr, Pb, Zn, Fe, As 등의 중금속이 포함되어 있으나 용출된 중금속의 농도는 우리나라의 폐기물관리기준치 미만으로 검출되었다. 시멘트로 고화처리된 바닥소각재에는 Cr, Cu, Pb, As 등의 중금속이 검출되었으며, Cd는 검출이 되지 않았다. 시멘트로 고화처리된 바닥소각재의 중금속 용출량은 바닥소각재의 중금속 용출량보다 감소되는 것으로 나타났다. 이는 바닥소각재에 포함된 중금속이 시멘트 성분에 의하여 고정화/안정화 작용을 일으킨 것으로 판단된다.

      • KCI등재

        Decision Tree model을 이용한 철도 주변 산사태 발생가능성 예측

        윤중만,송영석,박권준,유승경 한국지반신소재학회 2017 한국지반신소재학회 논문집 Vol.16 No.4

        In this study, the prediction of landslide probability was performed to the study area located in ◯◯ area of Muan-gun, Jeonnam Province around Honam railway using the computer program SHAPP ver 1.0 developed by a decision tree model. The soil samples were collected at total 8 points, and soil tests were performed to measure soil properties. The thematic maps of soil properties such as coefficient of permeability and void ratio were made on the basis of soil test results. The slope angle analysis of topography was performed using a digital map. As the prediction result of landslide probability, 435 cells among total 15,552 cells were predicted to be in the event of landslides. Therefore, the predicted area of occurring landslides may be 43,500 m2 because the analyzed cell size was 10 m×10 m. 본 연구에서는 Decision Tree model을 기반으로 개발된 산사태 예측프로그램 SHAPP ver 1.0을 이용하여 전라남도 무안군◯◯지역의 호남선 철도 주변에 대한 산사태 발생예측을 실시하였다. 이를 위하여 먼저 대상지역의 총 8개소에서 토층시료를채취하고, 이에 대한 토질시험을 실시하였다. 대상지역에 대한 토질시험결과를 토대로 투수계수와 간극비에 대한 주제도를작성하고 수치지형도를 이용하여 지형의 경사분석을 실시하였다. 이를 이용하여 산사태 발생예측을 실시한 결과 총 15,552개의 해석셀 가운데 435개의 셀에서 산사태가 발생될 것으로 예측되었다. 이때 해석셀의 크기는 10m×10m이므로 산사태 발생예상 면적은 43,500m2으로 나타났다.

      • KCI등재

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼