박용환,김상욱,김범규 한국화재소방학회 2013 한국화재소방학회논문지 Vol.27 No.1
It is necessary to use pressure reducing valves to provide required water pressure in water-based fire suppression systems of the tall buildings. In many cases, however, pressure reducing valves lose their function due to the phenomenon of pressure equalization caused by valve leak. This study carried out performance evaluation of the recently developed pressure reducing valve to prevent pressure equalization and found it can maintain designed pressure reducing ratio within 11 % variation and prevent pressure equalization by automatic self-lock function of the piston. 초고층건물의 수계소화설비에 있어서 적정 방수압력을 제공하기 위해서는 감압밸브의 사용이 필수적이다. 하지만 많은경우 밸브 내 누설로 인한 균압 현상으로 인해 감압 기능을 상실하는 경우가 많다. 본 연구에서는 최근 개발된 균압 현상을 자동으로 방지해 줄 수 있는 새로운 개념의 감압밸브에 대한 성능평가를 수행하였다. 그 결과 다양한 설정 조건에도 불구하고 설계 감압비가 최대 약 11 % 범위 내에서 유지되었으며, 피스톤의 자동 셀프 록(self-lock) 기능에 의해 균압 현상도 방지할 수 있는 것으로 나타났다.
박용환,최종우,김흥근,김진규,최영태,노의철,전태원 전력전자학회 2003 전력전자학회 논문지 Vol.8 No.4
유도전동기의 벡터제어를 수행하기 위해서 회전자 자속의 위치정보가 필수적이다. 하지만 정확한 회전자 위치정보를 얻기 위해서는 속도정보가 필수적이다. 속도정보 없는 개루프 방식의 제어나 전동기 방정식을 이용하는 방법들은 노이즈나 전동기 상수오차등에 의해 적용하기 어렵다. 본 논문에서는 자속관측기와 속도추정기를 분리하여 임의의 자속관측기를 사용할 수 있는 속도추정기를 제안하고 기존의 세 가지 자속관측기를 제안된 속도추정기에 적용하였다. 시뮬레이션 및 실험을 통하여 제안된 속도추정기의 타당성을 검증하였고 세 가지 자속관측기의 특성을 분석하였다. The rotor flux position is needed to perform vector control of induction motor. But rotor speed information is needed to get accurate the rotor flux position. It is difficult to implement the open loop method without speed information or the motor equation only because of noise or the motor parameter error. This paper presents the speed estimator can use the arbitrary rotor flux observer by separating the flux observer and speed estimator and apply the three flux observers proposed by Ohtani, Lorenz and full order flux observer. The validity of speed estimator presented is verified and the performance using the three rotor flux observers is analyzed by the simulation and experiment.
박용환 한국안전학회 2004 한국안전학회지 Vol.19 No.1
CNG buses were introduced in 2000 to reduce air pollution of the big cities. The durability and safety evaluation were perfomned for the NGV-2 type cylinders taken from two buses after 30 months of running. No external damage and no internal corrosion was observed on the container surfaces. Defect exceeding the allowable limit was not found in the UT test. Permanent volume expansion was about 1.2% which is much smaller than the required design limit. Cycling test showed no failure after 11,250cycles and burst pressures were still above the maximum design pressure. Both the longitudinal and circumferential failure mode were observed, where both the fracture strengths were far above the design limit. This study showed the present CNG fuel cylinders were safe enough for f other usage.