http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
康泰永 최신의학사 1972 最新醫學 Vol.15 No.10
Hemophilia is a hereditary disease of blood which occurs in males and transmitted by female. It was manifested with prolonged and repeated bleedings into the joints. Repeated hemorrhage into the joints, Precipitated by the trauma of motions, weightbearing, or minor external violence, may be followed by incomplete absorption of blood and later by organization and proliferation of bone at the articular cartilage, overgrowth of the synovium, and proliferlation of bone at the articular cartilage edges may take place. This paper described a case of hemophilia. A type in a managed 22 years old soldier was admitted with painful limitation of motions in the right knee. Auther attempted to treated this patient by bed rest, local hot compression, transfusion of fresh blood and traction. We could be achieved clinical improvment.
강태영,최민철,이효종,Kang Tae-Young,Choi Min-Cheol,Lee Hyo-Jong 한국임상수의학회 1992 한국임상수의학회지 Vol.9 No.2
This experiment was carried out to establish the grade of adhesion formation and changes of blood following artificial injuries such as abrasion, incision and electrocautery on colon and uterine horns in rats. 36 rats (abrasion-, incision-, electrocautery-treated groups) had laparotomy and abdominal injuries, twelve rats( control group) had only laparotomy, Ten days fellowing abdominal injuries, the score of adhesion formation and changes of blood were noted 1. Electrocautery-treated group was significant evident in adhesion formation in colon(p<0.01) and electrocautery and incision-treated groups were more evident than abrasion and control group in uterine horns(p<0.01) 2. Changes of erythrocytes number and PCV were tended to decrease during 5 days after operation, but recover normal level 10 days after operation. 3. Changes of leucocytes number were showed to significantly increase in electrocautery and incision-treated groups 5 days after operation. 4. The electrocautery-treated group was showed to significantly decrease in plasma protein and increase in plasma fibrinogen concentration.
석유화학 플랜트 프로젝트 상세설계 실패사례활용방안에 대한 연구
강태영,문승재,유호선,Kang, Tae-Young,Moon, Seung-Jae,Yoo, Hoseon 한국플랜트학회 2009 플랜트 저널 Vol.5 No.2
The capability of design and engineering of global EPC companies has long been equalized through past similar construction experiences. Among various key factors in the success of EPC project, the capability of engineering is considered to be the most important factor since the engineering is preceding activities of EPC contract. The failure of engineering may adversely affect the subsequent procurement & construction activities and in turn may cause cost overrun or schedule delay. Therefore, an EPC company needs to continue to improve the engineering capabilities for the success of project. The engineering capabilities can be further improved if the EPC company should prevent recurrence of similar design faults that were previously committed. This study is intended to present how to make the most of the failure examples from previous projects towards a success of project. Failure is but a stepping stone to success. The EPC company can obtain useful lessons from the analysis of past failure examples.
Evaluation of Extended Boar Semen after Glass Wool Filtration
강태영 한국임상수의학회 2015 한국임상수의학회지 Vol.32 No.1
The purpose of this study was to select high-quality boar semen after the glass wool filtration of extended boar semen. After collecting boar semen, its concentration, morphology, viability, and motility were examined according the glass wool’s height and time. After glass wool filtration, the sperm concentration decreased, but the proportion of normal sperms and the sperm viability increased. Nevertheless, the sperm motility showed no changes. The above results showed that the glass wool filtration of boar semen is a method of obtaining sperms with relatively low abnormal rates and high viabilities.
PECVD 이용한 비정질 실리콘형 마이크로 볼로미터 특성
강태영,김경환 한국반도체디스플레이기술학회 2012 반도체디스플레이기술학회지 Vol.11 No.4
We report microbolometer characteristic with n-type and p-type amorphous silicon thin film. The n-type and p-type amorphous silicon thin films were made by PECVD. The electrical properties of n-type and p-type a-Si:H thin films were investigated as a function of doping gas flow rate. The doping gas used B2H6/Ar (1:9) and PH3/Ar (1:9). In general, the conductivity of doping a-Si:H thin films increased as doping gas increase but the conductivity of a-Si:H thin films decreased as the doping gas increase because doping gas concentration increase led to dilution gas (Ar) increase as the same time. We fabricated an amorphous silicon microbolometer using surface micromachining technology. The fabricated microbolometer had a negative TCR of 2.3%. The p-type microbolometer had responsivity of 5×104 V/W and high detectivity of 3×108 cm(Hz)1/2/W. The p-type microbolometer had more detectivity than n-type for less noise value