RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        Evaluation of penetration depth of 2% chlorhexidine digluconate into root dentinal tubules using confocal laser scanning microscope

        Vadhana, Sekar,Latha, Jothi,Velmurugan, Natanasabapathy The Korean Academy of Conservative Dentistry 2015 Restorative Dentistry & Endodontics Vol.40 No.2

        Objectives: This study evaluated the penetration depth of 2% chlorhexidine digluconate (CHX) into root dentinal tubules and the influence of passive ultrasonic irrigation (PUI) using a confocal laser scanning microscope (CLSM). Materials and Methods: Twenty freshly extracted anterior teeth were decoronated and instrumented using Mtwo rotary files up to size 40, 4% taper. The samples were randomly divided into two groups (n = 10), that is, conventional syringe irrigation (CSI) and PUI. CHX was mixed with Rhodamine B dye and was used as the final irrigant. The teeth were sectioned at coronal, middle and apical levels and viewed under CLSM to record the penetration depth of CHX. The data were statistically analyzed using Kruskal-Wallis and Mann-Whitney U tests. Results: The mean penetration depths of 2% CHX in coronal, middle and apical thirds were $138{\mu}m$, $80{\mu}m$ and $44{\mu}m$ in CSI group, respectively, whereas the mean penetration depths were $209{\mu}m$, $138{\mu}m$ and $72{\mu}m$ respectively in PUI group. Statistically significant difference was present between CSI group and PUI group at all three levels (p < 0.01 for coronal third and p < 0.001 for middle and apical thirds). On intragroup analysis, both groups showed statistically significant difference among three levels (p < 0.001). Conclusions: Penetration depth of 2% CHX into root dentinal tubules is deeper in coronal third when compared to middle and apical third. PUI aided in deeper penetration of 2% CHX into dentinal tubules when compared to conventional syringe irrigation at all three levels.

      • KCI등재

        Evaluation of penetration depth of 2% chlorhexidine digluconate into root dentinal tubules using confocal laser scanning microscope

        Sekar Vadhana,Jothi Latha,Natanasabapathy Velmurugan 대한치과보존학회 2015 Restorative Dentistry & Endodontics Vol.40 No.2

        Objectives: This study evaluated the penetration depth of 2% chlorhexidine digluconate (CHX) into root dentinal tubules and the influence of passive ultrasonic irrigation (PUI) using a confocal laser scanning microscope (CLSM). Materials and Methods: Twenty freshly extracted anterior teeth were decoronated and instrumented using Mtwo rotary files up to size 40, 4% taper. The samples were randomly divided into two groups (n = 10), that is, conventional syringe irrigation (CSI) and PUI. CHX was mixed with Rhodamine B dye and was used as the final irrigant. The teeth were sectioned at coronal, middle and apical levels and viewed under CLSM to record the penetration depth of CHX. The data were statistically analyzed using Kruskal-Wallis and Mann-Whitney U tests. Results: The mean penetration depths of 2% CHX in coronal, middle and apical thirds were 138 μm, 80 μm and 44 μm in CSI group, respectively, whereas the mean penetration depths were 209 μm, 138 μm and 72 μm respectively in PUI group. Statistically significant difference was present between CSI group and PUI group at all three levels (p < 0.01 for coronal third and p < 0.001 for middle and apical thirds). On intragroup analysis, both groups showed statistically significant difference among three levels (p < 0.001). Conclusions: Penetration depth of 2% CHX into root dentinal tubules is deeper in coronal third when compared to middle and apical third. PUI aided in deeper penetration of 2% CHX into dentinal tubules when compared to conventional syringe irrigation at all three levels.

      • KCI등재

        The effect of ultrasonic file sizes on smear layer removal in passive ultrasonic irrigation

        Hye-Ju Kang,Sera Jung,Ara Cho,Mi-Gon Park,Hyoung-Hoon Jo 대한치과의사협회 2020 대한치과의사협회지 Vol.58 No.5

        Objectives: The aim of this study was to evaluate the efficacy of CK files as an ultrasonic instrument, and to determine most efficient file size for smear layer removal. Materials and Methods: Thirty-six extracted human mandibular premolars with single, straight root canals and mature apices were mechanically prepared and randomly divided into three groups. Group 1 (Control) underwent conventional needle irrigation, Group 2 (CKS) underwent passive ultrasonic irrigation with a #20 CK file, and Group 3 (CKL) underwent passive ultrasonic irrigation with a #30 CK file. After preparation and irrigation, all teeth were dried and split with a chisel to obtain the mesial and distal half of their roots. Each sample was evaluated using a scanning electron microscope, and data were analyzed using the Kruskal-Wallis and Mann-Whitney rank sum tests (p<0.05). Results: The CKS group showed less debris in the apical third than the other groups (p<0.05). In this section, no significant difference was observed among the other groups. And, there was no significant difference among any groups for the middle third section. Conclusion: This study showed that PUI with #20 CK file removed more smear layer compared to using #30 CK file at the apical third of the root canal.

      • KCI등재

        Effect of three different irrigation solutions applied by passive ultrasonic irrigation

        Llena, Carmen,Forner, Leopoldo,Cambralla, Raquel,Lozano, Adrian The Korean Academy of Conservative Dentistry 2015 Restorative Dentistry & Endodontics Vol.40 No.2

        Objectives: This study evaluated the maximum depth and percentage of irrigant penetration into dentinal tubules by passive ultrasonic irrigation (PUI). Materials and Methods: Thirty extracted human teeth were instrumented and divided into three groups. According to final irrigation regimen, 5.25% sodium hypochlorite (Group A, NaOCl), 2% chlorhexidine (Group B, CHX) and saline solution (Group C, control group) were applied with Irrisafe 20 tips (Acteon) and PUI. Irrigant was mixed with 0.1% rhodamine B. Sections at 2 mm, 5 mm, and 8 mm from the apex were examined with confocal laser scanning microscopy (CLSM). The percentage and maximum depth of irrigant penetration were measured. Kruskal-Wallis test and Mann-Whitney test were performed for overall comparison between groups at each level and for pairwise comparison, respectively. Within a group, Wilcoxon test was performed among different levels. p values less than 0.05 were considered significant. Results: In all groups, highest penetration depth and percentage of penetration were observed at the 8 mm level. At 2 mm level, Groups A and B had significantly greater depths and percentages in penetration than Group C (p < 0.05), but there were no significant differences between Groups A and B. At 5 mm level, penetration depths and percentage of penetration was not significantly different among the groups. Conclusions: NaOCl and CHX applied by PUI showed similar depth and percentage of penetration at all evaluated levels.

      • KCI등재

        Effect of three different irrigation solutions applied by passive ultrasonic irrigation

        Carmen Llena,Leopoldo Forner,Raquel Cambralla,Adrian Lozano 대한치과보존학회 2015 Restorative Dentistry & Endodontics Vol.40 No.2

        Objectives: This study evaluated the maximum depth and percentage of irrigant penetration into dentinal tubules by passive ultrasonic irrigation (PUI). Materials and Methods: Thirty extracted human teeth were instrumented and divided into three groups. According to final irrigation regimen, 5.25% sodium hypochlorite (Group A, NaOCl), 2% chlorhexidine (Group B, CHX) and saline solution (Group C, control group) were applied with Irrisafe 20 tips (Acteon) and PUI. Irrigant was mixed with 0.1% rhodamine B. Sections at 2 mm, 5 mm, and 8 mm from the apex were examined with confocal laser scanning microscopy (CLSM). The percentage and maximum depth of irrigant penetration were measured. Kruskal-Wallis test and Mann-Whitney test were performed for overall comparison between groups at each level and for pairwise comparison, respectively. Within a group, Wilcoxon test was performed among different levels. p values less than 0.05 were considered significant. Results: In all groups, highest penetration depth and percentage of penetration were observed at the 8 mm level. At 2 mm level, Groups A and B had significantly greater depths and percentages in penetration than Group C (p < 0.05), but there were no significant differences between Groups A and B. At 5 mm level, penetration depths and percentage of penetration was not significantly different among the groups. Conclusions: NaOCl and CHX applied by PUI showed similar depth and percentage of penetration at all evaluated levels.

      • KCI등재

        Comparison of the mechanical efficacy of sonic activated irrigation and passive ultrasonic irrigation for intracanal medicaments removal

        Ju-Kyong Jang,Sangwon Kwak,Ga Young Choi,Jung-Hong Ha,Sung-Baik Choi,Hyeon-Cheol Kim 대한치과의사협회 2015 대한치과의사협회지 Vol.53 No.10

        Objectives: This study compared the mechanical efficacy of sonic activated and passive ultrasonic irrigation for removing intracanal medicament from a simulated root canal under controlled conditions. Materials and Methods: Thirty simulated root canal in resin blocks were randomly divided into 3-groups. The canals were enlarged using ProTaper files and K3XF (#30/0.06). After cleaning and drying, canals were filled with Calcipex. Overfilled materials were wiped out and measured their weight to the unit of 1/10mg. After one week storage in 100% humidity 37℃ temperature, canals were irrigated using 20mL of saline with one of following methods according to the designated groups (n = 10). For group-NI, 30-gauge nickel-titanium irrigation needle was used. During irrigation with every 5mL, needle was moved in-and-out with 4-mm amplitudes. EndoActivator and ultrasonic tip were used for group-EA and group-UT respectively for 20 seconds after every 5mL irrigation using needle. Then the weight was measured again to calculate the weight of residual remnants. The data were analyzed by one-way ANOVA and Duncan’s post-hoc test at a significance level of 95%. Results: The weight of the residual medicaments were 3.62±0.81 mg, 2.84±0.28 mg, and 2.73±0.90 mg for group-NI, -EA, and -UT, respectively. Group-EA and group-UT had no significant differences to remove intracanal medicament and left significantly less amount of paste than group-NI (p < 0.05). Conclusions: Under the controlled conditions of this study, the sonic activation and PUI have similar mechanical efficacy for removing intracanal medicament.

      • KCI등재

        Comparison of the mechanical efficacy of sonic activated irrigation and passive ultrasonic irrigation for intracanal medicaments removal

        Jang, Ju-Kyong,Kwak, Sangwon,Choi, Ga Young,Ha, Jung-Hong,Choi, Sung-Baik,Kim, Hyeon-Cheol The Korean Dental Association 2015 대한치과의사협회지 Vol.53 No.10

        Objectives: This study compared the mechanical efficacy of sonic activated and passive ultrasonic irrigation for removing intracanal medicament from a simulated root canal under controlled conditions. Materials and Methods: Thirty simulated root canal in resin blocks were randomly divided into 3-groups. The canals were enlarged using ProTaper files and K3XF (#30/0.06). After cleaning and drying, canals were filled with Calcipex. Overfilled materials were wiped out and measured their weight to the unit of 1/10mg. After one week storage in 100% humidity $37^{\circ}C$ temperature, canals were irrigated using 20mL of saline with one of following methods according to the designated groups (n = 10). For group-NI, 30-gauge nickel-titanium irrigation needle was used. During irrigation with every 5mL, needle was moved in-and-out with 4-mm amplitudes. EndoActivator and ultrasonic tip were used for group-EA and group-UT respectively for 20 seconds after every 5mL irrigation using needle. Then the weight was measured again to calculate the weight of residual remnants. The data were analyzed by one-way ANOVA and Duncan's post-hoc test at a significance level of 95%. Results: The weight of the residual medicaments were $3.62{\pm}0.81mg$, $2.84{\pm}0.28mg$, and $2.73{\pm}0.90mg$ for group-NI, -EA, and -UT, respectively. Group-EA and group-UT had no significant differences to remove intracanal medicament and left significantly less amount of paste than group-NI (p < 0.05). Conclusions: Under the controlled conditions of this study, the sonic activation and PUI have similar mechanical efficacy for removing intracanal medicament.

      • KCI등재

        Comparison of the mechanical efficacy of sonic activated irrigation and passive ultrasonic irrigation for intracanal medicaments removal

        장주경,곽상원,최가영,하정홍,최성백,김현철 대한치과의사협회 2015 대한치과의사협회지 Vol.53 No.10

        Objectives: This study compared the mechanical efficacy of sonic activated and passive ultrasonic irrigation for removing intracanal medicament from a simulated root canal under controlled conditions. Materials and Methods: Thirty simulated root canal in resin blocks were randomly divided into 3-groups. The canals were enlarged using ProTaper files and K3XF (#30/0.06). After cleaning and drying, canals were filled with Calcipex. Overfilled materials were wiped out and measured their weight to the unit of 1/10mg. After one week storage in 100% humidity 37 temperature, canals were irrigated using 20mL of saline with one of following methods according to the designated groups (n = 10). For group-NI, 30-gauge nickel-titanium irrigation needle was used. During irrigation with every 5mL, needle was moved in-and-out with 4-mm amplitudes. EndoActivator and ultrasonic tip were used for group-EA and group-UT respectively for 20 seconds after every 5mL irrigation using needle. Then the weight was measured again to calculate the weight of residual remnants. The data were analyzed by one-way ANOVA and Duncan’s post-hoc test at a significance level of 95%. Results: The weight of the residual medicaments were 3.62 0.81 mg, 2.84 0.28 mg, and 2.73 0.90 mg for group-NI, -EA, and -UT, respectively. Group-EA and group-UT had no significant differences to remove intracanal medicament and left significantly less amount of paste than group-NI (p < 0.05). Conclusions: Under the controlled conditions of this study, the sonic activation and PUI have similar mechanical efficacy for removing intracanal medicament.

      • KCI등재
      • KCI등재

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼