Sadleir, R.J.,Sajib, S.Z.K.,Kim, H.J.,Kwon, O.I.,Woo, E.J. Academic Press 2013 Journal of magnetic resonance Vol.230 No.-
MREIT is a new imaging modality that can be used to reconstruct high-resolution conductivity images of the human body. Since conductivity values of cancerous tissues in the breast are significantly higher than those of surrounding normal tissues, breast imaging using MREIT may provide a new noninvasive way of detecting early stage of cancer. In this paper, we present results of experimental and numerical simulation studies of breast MREIT. We built a realistic three-dimensional model of the human breast connected to a simplified model of the chest including the heart and evaluated the ability of MREIT to detect cancerous anomalies in a background material with similar electrical properties to breast tissue. We performed numerical simulations of various scenarios in breast MREIT including assessment of the effects of fat inclusions and effects related to noise levels, such as changing the amplitude of injected currents, effect of added noise and number of averages. Phantom results showed straightforward detection of cancerous anomalies in a background was possible with low currents and few averages. The simulation results showed it should be possible to detect a cancerous anomaly in the breast, while restricting the maximal current density in the heart below published levels for nerve excitation.
Noise analysis in magnetic resonance electrical impedance tomography at 3 and 11 T field strengths
Sadleir, Rosalind,Grant, Samuel,Zhang, Sung Uk,Lee, Byung Il,Pyo, Hyun Chan,Oh, Suk Hoon,Park, Chunjae,Woo, Eung Je,Lee, Soo Yeol,Kwon, Ohin,Seo, Jin Keun IOP Pub 2005 Physiological measurement Vol.26 No.5
<P>In magnetic resonance electrical impedance tomography (MREIT), we measure the induced magnetic flux density inside an object subject to an externally injected current. This magnetic flux density is contaminated with noise, which ultimately limits the quality of reconstructed conductivity and current density images. By analysing and experimentally verifying the amount of noise in images gathered from two MREIT systems, we found that a carefully designed MREIT study will be able to reduce noise levels below 0.25 and 0.05 nT at main magnetic field strengths of 3 and 11 T, respectively, at a voxel size of 3 ? 3 ? 3 mm<SUP>3</SUP>. Further noise level reductions can be achieved by optimizing MREIT pulse sequences and using signal averaging. We suggest two different methods to estimate magnetic flux noise levels, and the results are compared to validate the experimental setup of an MREIT system.</P>
High field MREIT: setup and tissue phantom imaging at 11 T
Sadleir, Rosalind,Grant, Samuel,Zhang, Sung Uk,Oh, Suk Hoon,Lee, Byung Il,Woo, Eung Je IOP Pub 2006 Physiological measurement Vol.27 No.5
<P>Magnetic resonance electrical impedance tomography (MREIT) has the potential to provide conductivity and current density images with high spatial resolution and accuracy. Recent experimental studies at a field strength of 3 T showed that the spatial resolution of conductivity and current density images may be similar to that of conventional MR images as long as enough current is injected, at least 20 mA when the object being imaged has a size similar to the human head. To apply the MREIT technique to image small conductivity changes using less injection current, we performed MREIT studies at 11 T field strength, where noise levels in measured magnetic flux density data are significantly lower. In this paper we present the experimental results of imaging biological tissues with different conductivity values using MREIT at 11 T. We describe technical difficulties encountered in using high-field MREIT systems and possible solutions. High-field MREIT is suggested as a research tool for obtaining accurate conductivity data from tissue samples and animal subjects.</P>
Numerical Simulations of MREIT Conductivity Imaging for Brain Tumor Detection
Meng, Zi Jun,Sajib, Saurav Z. K.,Chauhan, Munish,Sadleir, Rosalind J.,Kim, Hyung Joong,Kwon, Oh In,Woo, Eung Je Hindawi Publishing Corporation 2013 Computational and mathematical methods in medicine Vol.2013 No.-
<P>Magnetic resonance electrical impedance tomography (MREIT) is a new modality capable of imaging the electrical properties of human body using MRI phase information in conjunction with external current injection. Recent <I>in vivo</I> animal and human MREIT studies have revealed unique conductivity contrasts related to different physiological and pathological conditions of tissues or organs. When performing <I>in vivo</I> brain imaging, small imaging currents must be injected so as not to stimulate peripheral nerves in the skin, while delivery of imaging currents to the brain is relatively small due to the skull's low conductivity. As a result, injected imaging currents may induce small phase signals and the overall low phase SNR in brain tissues. In this study, we present numerical simulation results of the use of head MREIT for brain tumor detection. We used a realistic three-dimensional head model to compute signal levels produced as a consequence of a predicted doubling of conductivity occurring within simulated tumorous brain tissues. We determined the feasibility of measuring these changes in a time acceptable to human subjects by adding realistic noise levels measured from a candidate 3 T system. We also reconstructed conductivity contrast images, showing that such conductivity differences can be both detected and imaged. </P>
Accelerating acquisition strategies for low-frequency conductivity imaging using MREIT
Song, Yizhuang,Seo, Jin Keun,Chauhan, Munish,Indahlastari, Aprinda,Ashok Kumar, Neeta,Sadleir, Rosalind IOP 2018 Physics in medicine & biology Vol.63 No.4
<P>We sought to improve efficiency of magnetic resonance electrical impedance tomography data acquisition so that fast conductivity changes or electric field variations could be monitored. Undersampling of k-space was used to decrease acquisition times in spin-echo-based sequences by a factor of two. Full MREIT data were reconstructed using continuity assumptions and preliminary scans gathered without current. We found that phase data were reconstructed faithfully from undersampled data. Conductivity reconstructions of phantom data were also possible. Therefore, undersampled k-space methods can potentially be used to accelerate MREIT acquisition. This method could be an advantage in imaging real-time conductivity changes with MREIT.</P>
Nanofiber Web Textile Dry Electrodes for Long-Term Biopotential Recording
Tong InOh,Sun Yoon,Tae Eui Kim,Hun Wi,Kap Jin Kim,Eung Je Woo,Sadleir, Rosalind J. IEEE 2013 IEEE transactions on biomedical circuits and syste Vol.7 No.2
<P>Electrode properties are key to the quality of measured biopotential signals. Ubiquitous health care systems require long-term monitoring of biopotential signals from normal volunteers and patients in home or hospital environments. In these settings it is appropriate to use dry textile electrode networks for monitoring purposes, rather than the gel or saline-sponge skin interfaces used with Ag/AgCl electrodes. In this study, we report performance test results of two different electrospun conductive nanofiber webs, and three metal plated fabrics. We evaluated contact impedance, step response, noise and signal fidelity performance indices for all five dry electrodes, and compared them to those of conventional Ag/AgCl electrodes. Overall, we found nanofiber web electrodes matched Ag/AgCl electrode performance more closely than metal plated fabric electrodes, with the contact resistance and capacitance of Ag plated PVDF nanofiber web electrodes being most similar to Ag/AgCl over the 10 Hz to 500 kHz frequency range. We also observed that step responses of all three metal-plated fabrics were poorer than those for nanofiber web electrodes and Ag/AgCl. Further, noise standard deviation and noise power spectral densities were generally lower in nanofiber web electrodes than metal plated fabrics; and waveform fidelity of ECG-like traces recorded from nanofiber web electrodes was higher than for metal plated fabrics. We recommend textile nanofiber web electrodes in applications where flexibility, comfort and durability are required in addition to good electrical characteristics.</P>