Economic Assessments of LFAC and HVDC Transmissions for Large Offshore Wind Farms
Park, Taesik,Kwak, Nohong,Moon, Chaeju,Cha, Seungtae,Kwon, Seongchul Korea Electric Power Corporation 2015 KEPCO Journal on electric power and energy Vol.1 No.1
Offshore wind farms extend a distance from an onshore grid to increase their generating power, but long distance and high power transmissions raise a lot of cost challenges. LFAC (Low Frequency AC) transmission is a new promising technology in high power and low cost power transmission fields against HVDC (High Voltage DC) and HVAC (High Voltage AC) transmissions. This paper presents an economic comparison of LFAC and HVDC transmissions for large offshore wind farms. The economic assessments of two different transmission technologies are analyzed and compared in terms of wind farm capacities (600 MW and 900 MW) and distances (from 25 km to 100 km) from the onshore grid. Based on this comparison, the economic feasibility of LFAC is verified as a most economical solution for remote offshore wind farms.
Predicting the Financial Behavior of the Religious Organization Board in Indonesia
ABBAS, Djamila,ALI, Muhammad,NOHONG, Mursalim,SOBARSYAH, Muhammad Korea Distribution Science Association 2020 The Journal of Asian Finance, Economics and Busine Vol.7 No.12
The religious organization members have a unique take on the spiritual factors related to their daily life. The present study contributed to the lack of discussion investigating this particular pool of data's financial behavior. This article regressed several predictors of economic behavior, i.e., the locus of control, financial attitude, income, and religiosity, with 460 respondents. The results of the research are as follows: Financial attitude partially influences the financial behavior of Muhammadiyah committee members. Income partially influences the financial behavior of Muhammadiyah committee members. This research indicates that income is one of the factors that plays an essential role in determining the merits of improvement of the financial behavior of Muhammadiyah committee members. The higher the level of income received by Muhammadiyah members, the higher the desire to spend the money. Religiosity partially influences the financial behavior of the religious board of Muhammadiyah members in Indonesia. The higher the religiosity of Muhammadiyah committee members will encourage better financial management. Religiosity indicates how often individuals or Muhammadiyah members practice the religious sharia that they embrace. The findings of this study reveal that locus of control, financial attitude, income, and religiosity are the strong predictors of the board of the religious organization's financial behavior in Indonesia.
DGA Gases related to the Aging of Power Transformers for Asset Management
Dongjin Kweon,Yonghyun Kim,Taesik Park,Nohong Kwak,Yongho Hur 대한전기학회 2018 Journal of Electrical Engineering & Technology Vol.13 No.1
Life management technology is required as the failure risk of aged power transformers increases. Asset management technology is developed to evaluate the remaining life, establish the replacement strategies, and decide the optimal investment based on the reliability and economy of power transformers. The remaining life assessment uses data such as installation, operation, maintenance, refurbishment, and failure of power transformers. The optimal investment also uses data such as maintenance, outage, and social costs. To develop the asset management system for power transformers, determining the degradation parameters related to the aging of power transformers and evaluating the condition of power transformers using these parameters are important. In this study, since 1983, 110,000 Dissolved Gas Analysis (DGA) data have been analyzed to determine the degradation parameters related to the aging of power transformers. The alarm rates of combustible gases (H₂, C₂H₂, C₂H₄, CH₄, and C₂H₆), TCG, CO, and CO₂ were analyzed. The end of life and failure rate (bathtub curve) of power transformers were also calculated based on the failure data from 1981 to 2014. The DGA gases related to discharge, overheating, and insulation degradation were determined based on alarm and failure rates. C₂H₂, C₂H₆, and CO₂ were discharge, oxidation, and insulation degradation parameters related to the aging of power transformers.
DGA Gases related to the Aging of Power Transformers for Asset Management
Kweon, Dongjin,Kim, Yonghyun,Park, Taesik,Kwak, Nohong,Hur, Yongho The Korean Institute of Electrical Engineers 2018 Journal of Electrical Engineering & Technology Vol.13 No.1
Life management technology is required as the failure risk of aged power transformers increases. Asset management technology is developed to evaluate the remaining life, establish the replacement strategies, and decide the optimal investment based on the reliability and economy of power transformers. The remaining life assessment uses data such as installation, operation, maintenance, refurbishment, and failure of power transformers. The optimal investment also uses data such as maintenance, outage, and social costs. To develop the asset management system for power transformers, determining the degradation parameters related to the aging of power transformers and evaluating the condition of power transformers using these parameters are important. In this study, since 1983, 110,000 Dissolved Gas Analysis (DGA) data have been analyzed to determine the degradation parameters related to the aging of power transformers. The alarm rates of combustible gases ($H_2$, $C_2H_2$, $C_2H_4$, $CH_4$, and $C_2H_6$), TCG, CO, and $CO_2$ were analyzed. The end of life and failure rate (bathtub curve) of power transformers were also calculated based on the failure data from 1981 to 2014. The DGA gases related to discharge, overheating, and insulation degradation were determined based on alarm and failure rates. $C_2H_2$, $C_2H_6$, and $CO_2$ were discharge, oxidation, and insulation degradation parameters related to the aging of power transformers.