http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Jung‑Hun Lee,Min‑Su Park,Hong‑Seon Ahn,Kyung‑Won Park,Jun‑Seok Oh,Seung‑Gyu Jeon,Dong‑Kyu Kim,Jae‑Eon Kim 대한전기학회 2020 Journal of Electrical Engineering & Technology Vol.15 No.4
When large scales DG are connected to the distribution system of unidirectional power currents, bi-directional power currents are formed, making it impossible to use conventional overcurrent protection methods alone to detect and isolate fault sections for ground and short-circuit faults. To solve these problems, this study proposed the method of protection against single-line-ground fault of common neutral line multi-contact local power distribution system using distance relay and directional relay. The proposed protection method was applied to the common neutral multi-ground distribution system to validate the protection against single-line-ground fault through the PSCAD/EMTDC software package and efectively detect and isolate only the zone of single-line-ground fault without malfunctions.
Analysis of Genetic Diversity of Korean Wheat Cultivars Using Microsatellite DNA Polymorphisms
Park,Yong-Jin,Cho,Gyu-Taek,Ma,Kyung-Ho,Lee,Sok-Young,Lee,Jung-Ro,Kim,Young-Chang,Cho,Eun-Gi,Kim Chang-Yung,Nam,Jung-Hyun,Rao,V,Ramanatha,Kang,Hee-Kyoung 한국자원식물학회 2004 Plant Resources Vol.7 No.2
Genetic background and phylogenetic relationships among 20 Korean wheat cultivars were assessed using microsatellites after amplifying with 13 SSR primer pairs. Average allele number per primer pair was 3.36. Genetic similarities for every pair of cultivars ranged from 0.42 to 0.97, with 0.69 of overall average. Korean cultivars were divided into two major groups based on microsatellite DNA polymorphisms. Group I consisted of relatively old cultivars developed until 1970s, and group II contained the recent cultivars developed during 1980s and 1990s. Amongst old elite cultivars/lines, ‘Yukseung 3’, ‘Norin 12’ and ‘Norin 72’ contributed most to the genetic background of cultivars belonging to group I, and ‘Norin 4’, ‘Norin 12’, ‘Norin 43’ and ‘Norin 72’ to group II, respectively. The phylogenetic relationship of Korean wheat cultivars was in accordance with the genealogical data of each cultivar. The genetic background of each cultivar was assessed from the point of breeding and germplasm management such as variety identification and duplicated accessions for assisting in developing a system for the registration of new variety based on the molecular characterization in future.
Gyu-Tae Yeom,Hae-Geum Park1,Nam-Tae Kim,Sung-Woo Kim,Hyun Kim,Yoon-Jung Do,Young-Sin Kim,Soo-Bong Park,Jae-Hwan Kim,Sang-Rae Cho,Jae-Hyeon Cho,Yeoung-Gyu Ko 韓國受精卵移植學會 2013 한국동물생명공학회지 Vol.28 No.1
Body condition score (BCS) is a useful management tool for distinguishing differences in nutritional needs of cows in the herd. Although it is not always possible to quantify the nutrient content of the feed supplied to the donor cow, the nutritional status can be determined by the BCS. The objective of this study was to evaluate in vivo embryo production, return to estrous of donor and pregnancy rate of recipients following BCS in Hanwoo superovulation. Sixty nine Hanwoo donor cows were flushed on day 7 of estrus cycle with same FSH and artificial insemination by the same technicians. Embryos were recovered on 7 days after the third insemination by flushing the uterus with Embryo Collection Medium. The results obtained were as follows: No differences were observed in the efficiency of superovulation rates regardless of BCS (≤2.0, 2.5 to 3.0, and ≥3.5). The mean number of total embryos was each 5.20±0.86, 11.56±1.04, and 6.23±1.07. The mean number of transferable embryo from ≤2.0, 2.5 to 3.0, and ≥3.5 of BCS was 2.60±0.87, 7.94±0.89, and 4.75±1.32, respectively (p<0.05). Return to estrous regardless of donor BCS was no difference. The pregnancy rates of recipient were BCS ≤2.0 11.76%, 2.5 to 3.0 40.79%, and ≥3.5 11.11%, following transfer of fresh embryos produced in vivo, respectively. These results indicate that if the Hanwoo with BCS 2.5 to 3.3 are used for donor and recipient, the embryo production and the conception rate will be greater.
박창규,김재홍,김정구,안승호,박진석,김종성,진태은 대한금속재료학회 2005 대한금속·재료학회지 Vol.43 No.3
Hydrogen embrittlement (HE) mitigation on the low alloy steel was studied using electrochemical technique. This method can be applied to reduce HE susceptibility. Hydrogen induced cracking (HIC) characteristics of the low alloy steel was investigated in aerated and deaerated borate buffer solution (0.3M H₃BO₃ + 0.074M N₂B_(4)O_(7), pH 8.4). The electrochemical properties of the low alloy steel showed passive behavior in this environment. By performing galvanostatic and potentiostatic test, hydrogen was charged and discharged to specimens respectively. By applying the potential of +630 mV_(SCE), the accumulated hydrogen was eliminated electrochemically. A specimen discharged for 24h indicated the efficiency of the hydrogen discharge up to 99.9%. Slow strain rate tests (SSRT) results showed that a specimen with higher hydrogen concentration revealed inferior mechanical properties such as shorter time to fracture, lower elongation, ultimate tensile strength and yield strength values. Furthermore, SEM fractographs revealed that the higher the hydrogen concentration is, the more probable the features of brittle fracture are. (Received July 26, 2004)
외과계 감염증에 대한 Sulperazon(Sulbactam/cefoperazone) 및 Cefoperazone의 임상효과 비교연구
박규주,노동영,김상준,권오중,정중기,홍인규 대한화학요법학회 1990 대한화학요법학회지 Vol.8 No.2
Despite recent advances in development of antibiotics and antiseptic techniques, infection still remains to be one of the major problems in the surgical field. Due to development of bacterial resistance to commonly used antibiotics, there is always a need to develop a new antimicrobial agent which would overcome such resistance. Sulperazon (Sulbactam/Cefoperazone) is a combination drug of potent β-lactamase inhigitor, sulbactam, and cefoperazone which has broad antibacterial spectrum, which was developed to combat against β-lactamase producing microorganisms. In an effort to evaluate the efficacy and safety of sulperazone, we have randomly divided 40 patients (12 with perforated appendicitis, 10 with peritionitis, 6 with GB empyema, 6 with periproctal abscess, 3 with wound infection, 1 liver abscess, 1 pancreatic abscess, and 1 acute cholangitis) into 2 groups (20 patients in each group). One group received daily dose of 2 to 3 grams of sulperazon and the other group received daily dose of 2 to 3 grams of cefoperazone. Following results were obtained : 1. Clinical effect of sulperazon was cure in 16 patients (80%), improvement in 3 patients (15%), compaired to cure in 14 patients (70%), improvement in 4 patients (20%) for the cefoperazone group. 2. Using disc diffusion method, sulperazon was sensitive to all of the isolated microorganisms except β-hemolytic streptococci, which was moderately sensitive. Cefoperazone was sensitive to only E. coli, Pseudomonas aeruginosa and Serratia. 3. Microbiological effect of sulperazon was eradication of offending microorganisms in 16 patients (80%), compared to 14 patients (70%) in Cefoperazone group. 4. Overall clinical efficacy of sulperazon was 95%, compared to 80% for cefoperazone. 5. Adverse effects due to sulperazon was nausea and diarrhea which occurred in 1 patient respectively. 2 patients receiving cefoperazone experienced diarrhea. It can be concluded that sulperazon is a safe and effective antibiotic agent which can be used in surgical infection patients.
AC PDP 네 투명 유전층의 절연내력과 투과율에 관한 연구
박정후,이성현,손재봉,김규섭,조정수 釜山大學校生産技術硏究所 1998 生産技術硏究所論文集 Vol.54 No.-
AC PDP(plasma display panel)는 40인치 이상의 대화면 디스플레이 장치로서, AC PDP내 투명 유전층은 방전플라즈마중의 양이온 충격에 의해서 금속전극이 스파터되는 것을 보호하고, 유전층 표면에 벽전하를 형성하여 대화면 구동에 필요한 메모리기능을 부가하므로 방전 cell구조에서 필수적인 부분이다. 이러한 유전층은 우수한 절연내력을 가져야할 뿐 아니라 가시광을 투과시키기 위한 높은 투과율이 요구된다. 따라서 본 연구에서는 여러 조건들 하에서 유전층의 절연내력과 투과율에 관하여 논하였다. 그 결과 15μm 두께를 가지고 570℃에서 소성을 행한 유전층의 경우 최소 29V/μm의 절연 내력을 가졌고, 80%정도의 투과율을 나타내었다. 그러므로 AC PDP에서 적정유전층의 두께는 최고인 가전압에 대해서 약 80V 정도의 마진을 가지는 15μm정도가 적당하다고 생각된다. AC PDP(plasma display panel) is large display panel over 40 inch. The transparent dielectric layers in AC PDP are essential to the discharge cell structure, because they protect metal electrodes from sputtering by positive ion bombarding in discharge plasma and form a sheath of wall charges which are essential to memory function necessary to drive large panel. This layer should have high dielectric strength, and also be transparent because visiable light must pass through this layer. Therefore in this paper, we discussed the dielectric strength and transmittance coefficient of the dielectric layer under various conditions. As a result, on the 15μm thickness, the minimum dielectric strength was 29V/μm and the transmittance coefficient was about 80% after 570℃ firing process. It is considered that the resonable dielectric thickness in AC PDP is 15μm because it has about 80V margin on the maximum applied voltage.
광섬유 Fabry-Perot 간섭형 전류 및 전압센서 시스템의 제작
박동수,김명규,김창원,이정희,손병기 경북대학교 센서기술연구소 1994 센서技術學術大會論文集 Vol.5 No.1
Although the conventional current transformers(CTs) and the potential transformers(PTs) have been used in the power system, new method is demanded which can measure with safty, EMI(electro-magnetic interference)-free. Over the last few years, variours kinds of optical measurement systems have been studied. The optical CTs and PTs systems, however, are very complicated and large, and hence the systems have a difficulty to maintain and repair. A new type fiber optic voltage and current transducers were fabricated by using fiber optic Fabry-Perot interferometer and PZT. A simple optical signal processing circuits and its PC interface circuits were also designed.