http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Zhang, Peng,Li, Su-qin,Guo, Zi-jie,Zhang, Chang-quan,Yang, Chang-qiao,Han, Shuai-shuai The Korea Institute of Applied Superconductivity a 2018 한국초전도저온공학회논문지 Vol.20 No.2
Comprehensive utilization of zinc smelting iron slag not only solves environmental problems but also creates huge economic benefits. This study was conducted on the enrichment and recovery of ${\alpha}-Fe_2O_3$ from zinc smelting iron slag by superconducting HGMS technology. Several variables such as slurry flow velocity, slag concentration, magnetic field intensity and the amount of dispersing agent were tested in magnetic separation. In the experiments, obtained optimal magnetic separation parameters were 1.60 T of magnetic flux intensity, 600 mL/min of slurry flow velocity of, 15 g/L of slag concentration of, 0.10 g/L of dispersing agent. Under this condition, the content of ${\alpha}-Fe_2O_3$ was increased from 86.22% to 94.39% that can approach the Chinese national standard requirements (A level) of iron oxide red. It was concluded that using superconducting HGMS technology was an effective method for the purification of ${\alpha}-Fe_2O_3$ from zinc smelting iron slag.
Peng Wang,You-min Guo,Min Liu,Yong-qian Qiang,Xiao-juan Guo,Yi-li Zhang,Xiao-Yi Duan,Qiu-Juan Zhang,Weifeng Liang 대한영상의학회 2008 Korean Journal of Radiology Vol.9 No.5
Objective: We aimed to do a meta-analysis of the existing literature to assess the accuracy of prostate cancer studies which use magnetic resonance spectroscopy (MRS) as a diagnostic tool. Materials and Methods: Prospectively, independent, blind studies were selected from the Cochrane library, Pubmed, and other network databases. The criteria for inclusion and exclusion in this study referenced the criteria of diagnostic research published by the Cochrane center. The statistical analysis was adopted by using Meta-Test version 6.0. Using the homogeneity test, a statistical effect model was chosen to calculate different pooled weighted values of sensitivity, specificity, and the corresponding 95% confidence intervals (95% CI). The summary receiver operating characteristic (SROC) curves method was used to assess the results. Results: We chose two cut-off values (0.75 and 0.86) as the diagnostic criteria for discriminating between benign and malignant. In the first diagnostic criterion, the pooled weighted sensitivity, specificity, and corresponding 95% CI (expressed as area under curve [AUC]) were 0.82 (0.73, 0.89), 0.68 (0.58, 0.76), and 83.4% (74.97, 91.83). In the second criterion, the pooled weighted sensitivity, specificity, and corresponding 95% CI were 0.64 (0.55, 0.72), 0.86 (0.79, 0.91) and 82.7% (68.73, 96.68). Conclusion: As a new method in the diagnostic of prostate cancer, MRS has a better applied value compared to other common modalities. Ultimately, large scale RCT randomized controlled trial studies are necessary to assess its clinical value. Objective: We aimed to do a meta-analysis of the existing literature to assess the accuracy of prostate cancer studies which use magnetic resonance spectroscopy (MRS) as a diagnostic tool. Materials and Methods: Prospectively, independent, blind studies were selected from the Cochrane library, Pubmed, and other network databases. The criteria for inclusion and exclusion in this study referenced the criteria of diagnostic research published by the Cochrane center. The statistical analysis was adopted by using Meta-Test version 6.0. Using the homogeneity test, a statistical effect model was chosen to calculate different pooled weighted values of sensitivity, specificity, and the corresponding 95% confidence intervals (95% CI). The summary receiver operating characteristic (SROC) curves method was used to assess the results. Results: We chose two cut-off values (0.75 and 0.86) as the diagnostic criteria for discriminating between benign and malignant. In the first diagnostic criterion, the pooled weighted sensitivity, specificity, and corresponding 95% CI (expressed as area under curve [AUC]) were 0.82 (0.73, 0.89), 0.68 (0.58, 0.76), and 83.4% (74.97, 91.83). In the second criterion, the pooled weighted sensitivity, specificity, and corresponding 95% CI were 0.64 (0.55, 0.72), 0.86 (0.79, 0.91) and 82.7% (68.73, 96.68). Conclusion: As a new method in the diagnostic of prostate cancer, MRS has a better applied value compared to other common modalities. Ultimately, large scale RCT randomized controlled trial studies are necessary to assess its clinical value.
Physical properties and chemical composition of the cores in the California molecular cloud
Zhang, Guo-Yin,Xu, Jin-Long,Vasyunin, A. I.,Semenov, D. A.,Wang, Jun-Jie,Dib, Sami,Liu, Tie,Liu, Sheng-Yuan,Zhang, Chuan-Peng,Liu, Xiao-Lan,Wang, Ke,Li, Di,Wu, Zhong-Zu,Yuan, Jing-Hua,Li, Da-Lei,Gao, Springer-Verlag 2018 Astronomy and astrophysics Vol.620 No.-
<P><I>Aims.</I> We aim to reveal the physical properties and chemical composition of the cores in the California molecular cloud (CMC), so as to better understand the initial conditions of star formation.</P><P><I>Methods.</I> We made a high-resolution column density map (18.2′′) with <I>Herschel</I> data, and extracted a complete sample of the cores in the CMC with the fellwalker algorithm. We performed new single-pointing observations of molecular lines near 90 GHz with the IRAM 30m telescope along the main filament of the CMC. In addition, we also performed a numerical modeling of chemical evolution for the cores under the physical conditions.</P><P><I>Results.</I> We extracted 300 cores, of which 33 are protostellar and 267 are starless cores. About 51% (137 of 267) of the starless cores are prestellar cores. Three cores have the potential to evolve into high-mass stars. The prestellar core mass function (CMF) can be well fit by a log-normal form. The high-mass end of the prestellar CMF shows a power-law form with an index <I>α</I> = −0.9 ± 0.1 that is shallower than that of the Galactic field stellar mass function. Combining the mass transformation efficiency (<I>ε</I>) from the prestellar core to the star of 15 ± 1% and the core formation efficiency (CFE) of 5.5%, we suggest an overall star formation efficiency of about 1% in the CMC. In the single-pointing observations with the IRAM 30m telescope, we find that 6 cores show blue-skewed profile, while 4 cores show red-skewed profile. [HCO<SUP>+</SUP>]/[HNC] and [HCO<SUP>+</SUP>]/[N2H<SUP>+</SUP>] in protostellar cores are higher than those in prestellar cores; this can be used as chemical clocks. The best-fit chemical age of the cores with line observations is ~5 × 10<SUP>4</SUP> yr.</P>
Guo, Pi,Shen, Shun-Li,Zhang, Qin,Zeng, Fang-Fang,Zhang, Wang-Jian,Hu, Xiao-Min,Zhang, Ding-Mei,Peng, Bao-Gang,Hao, Yuan-Tao Asian Pacific Journal of Cancer Prevention 2014 Asian Pacific journal of cancer prevention Vol.15 No.14
Objectives: To evaluate the performance of clustering methods used in the prognostic assessment of categorical clinical data for hepatocellular carcinoma (HCC) patients in China, and establish a predictable prognostic nomogram for clinical decisions. Materials and Methods: A total of 332 newly diagnosed HCC patients treated with hepatic resection during 2006-2009 were enrolled. Patients were regularly followed up at outpatient clinics. Clustering methods including the Average linkage, k-modes, fuzzy k-modes, PAM, CLARA, protocluster, and ROCK were compared by Monte Carlo simulation, and the optimal method was applied to investigate the clustering pattern of the indices including platelet count, platelet/lymphocyte ratio (PLR) and serum aspartate aminotransferase activity/platelet count ratio index (APRI). Then the clustering variable, age group, tumor size, number of tumor and vascular invasion were studied in a multivariable Cox regression model. A prognostic nomogram was constructed for clinical decisions. Results: The ROCK was best in both the overlapping and non-overlapping cases performed to assess the prognostic value of platelet-based indices. Patients with categorical platelet-based indices significantly split across two clusters, and those with high values, had a high risk of HCC recurrence (hazard ratio [HR] 1.42, 95% CI 1.09-1.86; p<0.01). Tumor size, number of tumor and blood vessel invasion were also associated with high risk of HCC recurrence (all p< 0.01). The nomogram well predicted HCC patient survival at 3 and 5 years. Conclusions: A cluster of platelet-based indices combined with other clinical covariates could be used for prognosis evaluation in HCC.
Peng Zhang,Su-qin Li,Zi-jie Guo,Chang-quan Zhang,Chang-qiao Yang,Shuai-shuai Han 한국초전도.저온공학회 2018 한국초전도저온공학회논문지 Vol.20 No.2
Comprehensive utilization of zinc smelting iron slag not only solves environmental problems but also creates huge economic benefits. This study was conducted on the enrichment and recovery of α-Fe2O3 from zinc smelting iron slag by superconducting HGMS technology. Several variables such as slurry flow velocity, slag concentration, magnetic field intensity and the amount of dispersing agent were tested in magnetic separation. In the experiments, obtained optimal magnetic separation parameters were 1.60 T of magnetic flux intensity, 600 mL/min of slurry flow velocity of, 15 g/L of slag concentration of, 0.10 g/L of dispersing agent. Under this condition, the content of α-Fe2O3 was increased from 86.22% to 94.39% that can approach the Chinese national standard requirements (A level) of iron oxide red. It was concluded that using superconducting HGMS technology was an effective method for the purification of α-Fe2O3 from zinc smelting iron slag.
Cross-Technology Localization: Leveraging Commodity WiFi to Localize Non-WiFi Device
( Dian Zhang ),( Rujun Zhang ),( Haizhou Guo ),( Peng Xiang ),( Xiaonan Guo ) 한국인터넷정보학회 2021 KSII Transactions on Internet and Information Syst Vol.15 No.11
Radio Frequency (RF)-based indoor localization technologies play significant roles in various Internet of Things (IoT) services (e.g., location-based service). Most such technologies require that all the devices comply with a specified technology (e.g., WiFi, ZigBee, and Bluetooth). However, this requirement limits its application scenarios in today's IoT context where multiple devices complied with different standards coexist in a shared environment. To bridge the gap, in this paper, we propose a cross-technology localization approach, which is able to localize target nodes using a different type of devices. Specifically, the proposed framework reuses the existing WiFi infrastructure without introducing additional cost to localize Non-WiFi device (i.e., ZigBee). The key idea is to leverage the interference between devices that share the same operating frequency (e.g., 2.4GHz). Such interference exhibits unique patterns that depend on the target device's location, thus it can be leveraged for cross-technology localization. The proposed framework uses Principal Components Analysis (PCA) to extract salient features of the received WiFi signals, and leverages Dynamic Time Warping (DTW), Gradient Boosting Regression Tree (GBRT) to improve the robustness of our system. We conduct experiments in real scenario and investigate the impact of different factors. Experimental results show that the average localization accuracy of our prototype can reach 1.54m, which demonstrates a promising direction of building cross-technology technologies to fulfill the needs of modern IoT context.
Li Qin Zhang,Xiao Peng Zhang,Yu Ying Hao,Bao Li Zhang,Xin Dong Guo 한국공업화학회 2020 Journal of Industrial and Engineering Chemistry Vol.88 No.-
When overexposed to ultraviolet B (UVB) irradiation, skin can cause a series of abnormal reactions, suchas excessive pigmentation and solar elastosis. In order to better treat the skin after overexposed to UVB,we designed a dissolving microneedles (MNs) loading hydrophilic ascorbic acid and hydrophobic vitaminA palmitate to achieve codelivery. Here, we confirmed that MNs had enough mechanical strength toinsert the skin and two drugs were delivered subcutaneously in sequence in vitro. In white guinea pigs,surface observation and histological observation results confirmed that two drugs by MNs transdermaldelivery were better than topical administration in the treatment of UVB-damaged skin. The MNs providea method of loading different drugs into the needles and advance the development of transdermal drugdelivery.