RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 무료
      • 기관 내 무료
      • 유료
      • SCOPUSKCI등재

        적층형 ZnO바리스터의 내부전극과 Bi$_2$O$_3$ 와의 반응

        김영정,김환,홍국선,이종국,Kim, Young-Jung,Kim, Hwan,Hong, Kook-Sun,Lee, Jong-Kook 한국세라믹학회 1998 한국세라믹학회지 Vol.35 No.11

        Reactions between Ag-Pd internal electrode materials and{{{{ { {Bi }_{2 }O }_{3 } }} in multilayer chip varistor were in-vestigated. For more than 1 mol%{{{{ { {Bi }_{2 }O }_{3 } }} in varistor composition internal electrode structure was destroyed due to the reaction between internal electrode and{{{{ { {Bi }_{2 }O }_{3 } }} But for typical varistor compositions (below 1 mol% of{{{{ { {Bi }_{2 }O }_{3 } }} content) microstructural changes around the internal electrode were not observed. However SEM-EDS and TEM-EDS analysis showed the uneven distribution of{{{{ { {Bi }_{2 }O }_{3 } }} in the internal electrode which was due to the migration of{{{{ { {Bi }_{2 }O }_{3 } }} to the electorde during sintering. As a results the nonlinear coefficient of multilayer varistor showed very large distribution as well as the breakdown voltage.

      • KCI등재

        임상에서 실패된 치과 임플란트 고정체의 표면분석

        최한철 ( Han Cheol Choe ),홍국선 ( Kook Sun Hong ),고영무 ( Yeong Mu Ko ),김병옥 ( Byung Ock Kim ) 대한금속재료학회 ( 구 대한금속학회 ) 2006 대한금속·재료학회지 Vol.44 No.6

        The aim of this investigation was to analyze surface of clinically failed dental implant fixture in order to determine possible causes of failure. The failed implants were classified into three groups; 3 and 5 month used implant, 19 and 60 month used implant, and fractured implant, after implantation for 33 month and 120 month in patient jaws. The topography and surface chemical composition were studied with energy dispersive x-ray spectroscopy(EDS) and field emission scanning electron microscope(FE-SEM) to analyze elements on the surface of flank and bottom of thread. Evaluations were performed at the upper, middle and lower implant fixture. From surface observation of 3 and 5 month used implant, contaminants were detected in the middle and lower part of implants. Overall, foreign elements such as silicon, carbon, oxygen, zinc, sulfur, zirconium, and chloride were detected in failed implants. From surface observation of 19 and 60 month used implant, the corrosion was accelerated at the bottom of thread that was accumulated chloride. Corrosion products showed in the bottom of thread including dissolution elements, such as Au, Cu, Ag, from suprastructure of dental implant system. From surface observation of fatigue fractured implants, the crack were nucleated in the bottom of thread and the crack of corrosion fatigue was predominantly propagated. The corrosion products including chloride were found opposite side of starting point of corrosion fatigue crack. We could find the fatigue striation and estimate the dimple fracture of implants.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼