http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
환경비용과 전력거래요금 차이를 고려한 한-중 계통 연계선로 경제성 분석
정희원(Hui-Won Jeong),차준민(Junmin Cha),이규섭(Gyu-Sub Lee) 대한전기학회 2020 전기학회논문지 Vol.69 No.10
The Northeast Asia Super Grid, a large-scale power line interconnection project in Northeast Asia, is being reviewed in the second half of 2017. As a result, there is increasing interest in research on the feasibility of interconnection between countries. Prior to the interconnection business, reviewing the technical and economical analysis is an essential process. This paper is based on the review of technical feasibility in 2016 on the interconnected between Korea-China to submarine cable. There is based on the result of the technical feasibility of the shortest distance (380 km) of submarine cable among several Korea-China interconnection sites of previous studies. The Interconnection between Korea and China is configured by HVDC ±500kV submarine cable. The following three variables are considered to construct the scenario and analyze the economic feasibility : CO₂ reduction effect, power price uncertainty of both countries, economic comparison with additional power plants. For the analysis, we use the four indices NPV (Net Present Value), IRR (Internal Rate of Return), B/C ratio(Benefit-Cost ratio) and CRP(Cost Recovery Period). The economical analysis of these scenarios are shown in this study.
金炯徹(Hyungchul Kim),車濬敏(Junmin Cha),權世爀(Sae-hyuk Kwon) 대한전기학회 2006 전기학회논문지A Vol.55 No.5
The security analysis relates to the ability of the electric systems to survive sudden disturbances such as electric short circuits or unanticipated loss of system elements. It is composed of both steady state and dynamic security analyses, which are not two separate issues but should be considered together. In steady state security analysis including voltage security analysis, the analysis checks that the system is operated within security limits by OPF (optimal power flow) after the transition of a new operating point. On the other hand, dynamic security analysis deals that the transition will lead to an acceptable operating condition. Transient stability, which is the ability of power systems to maintain synchronism when subjected to a large disturbance, is a principal component in dynamic security analysis. Usually any loss of synchronism will cause additional outages. They make the present steady state analysis of the post-contingency condition inadequate for unstable cases. This is the reason of the need for dynamics of systems. Probabilistic criterion can be used to recognize the probabilistic nature of system components and shows the possibility of system security. A comprehensive conceptual framework for probabilistic static and dynamic assessment is presented in this paper. The simulation results of the Western System Coordinating Council (WSCC) system compare an analytical method with Monte-Carlo simulation (MCS). Also, a case study of the extended IEEE Reliability Test System (RTS) shows the efficiency of this approach.
김규형(Gyu-Hyoung Kim),차준민(Junmin Cha) 대한전기학회 2021 대한전기학회 학술대회 논문집 Vol.2021 No.10
우리나라에서는 신재생에너지 중 풍력 발전단지의 건설을 계획하고 있다. 풍력 발전단지가 추가됨에 따라 시스템의 고장률은 중요성이 매우 높다고 볼 수 있다. 본 논문에서는 고장률 산정을 위한 수식을 통해 풍력발전기의 구성요소별 고장률 산정하였다. 이후 풍력발전기를 포함한 시스템의 고장률을 산정하였고 풍력발전기의 댓수에 따른 고장률 산정을 수행하였다.
김형철(Hyungchul Kim),차준민(Junmin Cha),김진오(Jin-O Kim) 대한전기학회 2008 대한전기학회 학술대회 논문집 Vol.2008 No.10
RCM(reliability Centered Maintenance) 적용 시 나타나는 장점으로 인해 이미 여러 산업 분야에 적용되고 있다. 설비의 안정성을 중요시하는 원자력발전 부문에서 처음으로 도입 후 전력산업분야 대부분에서 RCM을 적용하거나 적용연구가 진행되고 있다. 철도산업에서도 전력산업 분야와 같이 안정적이면서 경제적인 전력을 공급하는 것이 중요하므로 정비업무의 중요성이 크다고 할 수 있다. 특히 철도 시스템 중 한전에서 154㎸나 345㎸를 수전 받아 철도 시스템에 전력을 공급하는 변전소의 역할은 매우 중요하다. 따라서 철도 변전소를 구성하고 있는 설비의 특성과 운영방식에 대한 연구를 통해 적절한 RCM적용 방안을 위한 고장모드 및 임계분석(FMECA: Failure Mode, Effects and Criticality Analysis) 연구의 필요성이 대두된다. RCM과 FMECA는 적용 산업분야에 따라 적용 절차를 다르게 적용되어진다. 따라서 철도 변전소에 대한 고장데이터와 설비들의 특성 및 현재 운용방식 등을 종합적으로 고려하여 적절한 수립방법 연구가 필요하다.