http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
연구논문 : 다중회귀모형을 이용한 벤츄리가 없는 충격기류식 여과집진장치 압력손실 예측
서정민 ( Jeong Min Suh ),박정호 ( Jeong Ho Park ),조재환 ( Jae Hwan Cho ),진경호 ( Kyung Ho Jin ),정문섭 ( Moon Sub Jung ),이병인 ( Pyong In Yi ),홍성철 ( Sung Chul Hong ),시바쿠마르최금찬 ( S Sivakumar ),최금찬 ( Kum Chan Choi ) 한국환경과학회 2014 한국환경과학회지 Vol.23 No.12
In this study, pressure drop was measured in the pulse jet bag filter without venturi on which 16 numbers of filter bags (Ø140 × 850 ℓ) are installed according to operation condition(filtration velocity, inlet dust concentration, pulse pressure, and pulse interval) using coke dust from steel mill. The obtained 180 pressure drop test data were used to predict pressure drop with multiple regression model so that pressure drop data can be used for effective operation condition and as basic data for economical design. The prediction results showed that when filtration velocity was increased by 1%, pressure drop was increased by 2.2% which indicated that filtration velocity among operation condition was attributed on the pressure drop the most. Pressure was dropped by 1.53% when pulse pressure was increased by 1% which also confirmed that pulse pressure was the major factor affecting on the pressure drop next to filtration velocity. Meanwhile, pressure drops were found increased by 0.3% and 0.37%, respectively when inlet dust concentration and pulse interval were increased by 1% implying that the effects of inlet dust concentration and pulse interval were less as compared with those changes of filtration velocity and pulse pressure. Therefore, the larger effect on the pressure drop the pulse jet bag filter was found in the order of filtration velocity(Vf), pulse pressure(Pp), inlet dust concentration(Ci), pulse interval(Pi). Also, the prediction result of filtration velocity, inlet dust concentration, pulse pressure, and pulse interval which showed the largest effect on the pressure drop indicated that stable operation can be executed with filtration velocity less than 1.5 m/min and inlet dust concentration less than 4 g/m3. However, it was regarded that pulse pressure and pulse interval need to be adjusted when inlet dust concentration is higher than 4 g/m3. When filtration velocity and pulse pressure were examined, operation was possible regardless of changes in pulse pressure if filtration velocity was at 1.5 m/min. If filtration velocity was increased to 2 m/min. operation would be possible only when pulse pressure was set at higher than 5.8 kgf/cm2. Also, the prediction result of pressure drop with filtration velocity and pulse interval showed that operation with pulse interval less than 50 sec. should be carried out under filtration velocity at 1.5 m/min. While, pulse interval should be set at lower than 11 sec. if filtration velocity was set at 2 m/min. Under the conditions of filtration velocity lower than 1 m/min and high pulse pressure higher than 7 kgf/cm2, though pressure drop would be less, in this case, economic feasibility would be low due to increased in installation and operation cost since scale of dust collection equipment becomes larger and life of filtration bag becomes shortened due to high pulse pressure.
설계인자 변화에 따른 소형 전기집진장치의 최적효율 예측
서정민 ( Jeong Min Suh ),이병인 ( Pyong In Yi ),정문섭 ( Moon Sub Jung ),박정호 ( Jeong Ho Park ),임우택 ( Woo Taik Lim ),박출재 ( Chool Jae Park ),최금찬 ( Kum Chan Choi ) 한국환경과학회 2013 한국환경과학회지 Vol.22 No.9
The result of a small electrostatic precipitator which is in order to decrease indoor air pollution for optimal efficiency was shown as follows. Although the closer distance between the discharge electrode and dust collecting electrode shows the better throughput efficiency by forming strong electrostatic Field, it does not have profound impact in case of optimal dust collecting area. G.P(gas passage) which is the distance from dust collecting electrode to dust collecting electrode is a crucial factor to decide dust collecting efficiency. The narrower distance of G.P shows the better throughput efficiency whereas it decreases when the distance is too narrow since sparks ensue by increasing the capacity of electrostatic charging system 5 mm regards as optimal efficiency in this experiment. Although the higher voltage shows the higher dust collecting efficiency overall, the experiment was not able to keep performing since the sparks which decrease dust collecting efficiency ensue over 40 kV. The efficient and safe voltage state is considered 3.6 kV in this experiment. The most crucial factor for dust collecting efficiency of an electrostatic precipitator which is in order to decrease indoor air pollution is applied voltage. In addition, optimal raw gas flow rate(2.4 m/sec) is more important factor than the excessive increase of dust collecting area.