http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
전현도(Jun Hyun-Do),박진철(Park Jin-Chul),이언구(Rhee Eon-Ku) 대한건축학회 2009 대한건축학회 학술발표대회 논문집 - 계획계/구조계 Vol.29 No.1(계획계)
The findings of this study can be summarized as follows. As for an super high rise building, it is analyzed that it's profitable to import a wind power system because we can get over 10m/s wind velocity on the higher stories than lower stories. In setting up a wind power system at a super high rise building, it is important to consider integrated design to attract as much wind in the surroundings as possible to the building. Such preliminary study will become a valuable resource to the further study on its feasibility through the actually measured data about the building load, noise, oscillation, and harmony with the surrounding buildings; and through CFD simulation verification and validation,
전현도(Jun Hyun-Do),박진철(Park Jin-Chul),이언구(Rhee Eon-Ku) 대한건축학회 2010 대한건축학회논문집 Vol.26 No.8
The research was conducted for the application of wind generator systems in high-rise buildings, and drew out elements to consider for the application of wind generation in high-rise buildings, especially, by providing a design process for application to high-rise buildings. Also, basic data for applying the wind generation system in high-rise buildings has been provided by case analysis and CFD simulation. The research results are summarized as follows; In an urban wind environment, the volatility of wind speeds become more severe as it gets closer to the surface of the earth, but because wind speeds become stronger with the rise in altitude, applying a wind generation system to a high-rise building is possible, even in an urban setting. That is, the average wind speeds on 200m high-rise buildings were 5.7~7.4㎧, while they were 6.6~8.0㎧ on 500m buildings. Among the many methods of applying wind generation to high-rise buildings, installation on the highest floor or to the side of buildings presented most advantageous in Korea because the average wind direction changes from season to season. In the simulation following the wind generation application process (72 floor mixed-use high-rise residential building), high wind speeds were able to be secured due to the high elevation of the building, and installation to both the roof section of the highest floor and parts of the side were feasible. In particular, the installed wind generation system was able to sufficiently cover a part of the total energy consumption of the high-rise building.
全泫 충남대학교 의과대학 지역사회의학연구소 1979 충남의대잡지 Vol.6 No.2
This study was conducted to observe incidence of various abnormalities in urine of school children. 937 apparent normal children in Keum San area were selected and analyzed by labstix on protein, pH, glucose, keton and occult blood of their urine during June to August in 1979. The results was summarized as followings ; 1. The rate of proteinuria was 1.49%. 2. The rate of urine pH above 7.5 was 0.3%. 3. The rate of urine occoult blood was 0.1%. 4. No glucosuria or ketonuria was detected.