이재빈,곽상현,김형준,박희대,김영식,Lee, Jae-Bin,Kwak, Sang-Hyon,Kim, Hyeong-Joon,Park, Hee-Dae,Kim, Young-Sik 한국재료학회 1999 한국재료학회지 Vol.9 No.12
An FBAR(Solidly Mounted Resonator) was fabricated using reflector layers which prohibit the penetration of bulk acoustic wave into substrate. The SMR consisted of top and bottom electrodes(Al films), a piezoelectric layer (ZnO film), reflector layers(W/$Si_2$ films) and Si substrate. The electrodes were deposited by dc sputtering. The piezoelectric layer and the reflector layers were deposited by rf magnetron sputtering. The control of crystallinity, microstructures and electric properties of each layer was essential for attaining the optimum FBAR characteristics. Under the best deposition conditions for FBAR devices, the ZnO films had highly c-axis preferred orientation(${\sigma}=2.17^{\circ}$), resistivity of $10^4\;{\omega}cm$, and surface roughness of 10.6 ${\AA}$. On the other hand, the surface roughness of W and $Si_2$ films was 16 ${\AA}$ and 33 ${\AA}$, respectively, and the resistivity of Al film was $5.1{\times}10^{-6}\;{\Omega}cm$. The SMR devices were fabricated by the conventional semiconductor processes. In the resonance conditions of the SMR, the series resonance frequency (fs) and the parallel resonance frequency(fp) were 1.244 GHz and 1.251 GHz, respectively and the quality factor(Q) was 1200. 본 실험에서는 반사층(reflector)을 이용한 FBAR (Film Bulk Acoustic Resonator) 즉, SMR (Solidly Mounted Resonator) 제조에 필요한 재료들의 최적 증착 조건을 설정하여, 이를 바탕으로 제조한 SMR의 특성을 보여주었다. SMR은 상하부 전극층, 압전 박막층, 반사층, 기판으로 구성된다. 상하부 전극으로 알루미늄(Al) 금속 박막을 사용하였고 압전 박막층으로 산화아연(ZnO) 박막을 사용하였다. 실리콘(Si) 기판과 하부 전극 사이에 위치하는 반사층은 5층의 이산화규소 ($Si_2$)와 텅스텐(W) 박막으로 구성되었다. 상하부 전극은 dc 스퍼터링 방법으로 증착아였으며 반사층과 압전 박막층은 rf 스퍼터링 방법으로 증착하였다. 최적 증착 조건에서 증착된 산화아연 (ZnO) 박막은 rocking curve에서 표준편차가 $2.17^{\circ}$의 우수한 c축 우선배향성, 비저항은 $10^4\;{\Omega}cm$이상, 막 표면 거칠기(rms roughness)는 10.6${\AA}$의 특성을 나타내었다. 최적 증착 조건에서 증착된 텅스텐(W)과 이산화규소($Si_2$) 박막의 특성은 박막 거칠기 (rms roughness)가 각각 16 ${\AA}$, 33 ${\AA}$을 나타내었다. 또한 증착된 알루미늄 금속 박막의 비저항은 $5.1{\times}10^{-6}\;{\Omega}cm$이었다. 반도체 기본 공정을 이용하여 면적 $250{\times}250\;{\mu}m^2$의 SMR 소자를 만들고, 네트웍 분석기로 SMR 소자의 공진 특성을 분석하였다. 공진특성은 1.244 GHz에서 직렬공진, 1.251 GHz에서 병렬공진을 나타내었다. SMR 소자의 공진특성에서 공진기의 Q값은 1200이었다.
탄소성 균열개시조건에 대한 원주방향 관통균열 배관의 부분안전계수 계산
이재빈(Jae-Bin Lee),허남수(Nam-Su Huh) 대한기계학회 2014 大韓機械學會論文集A Vol.38 No.11
최근 제4세대 원자로의 기기 최적설계를 위해 목표파손확률 기반 설계기법에 대한 연구가 활발히 진행되고 있다. 시스템기반코드(System-Based Code, SBC)가 대표적인 예로 설계 혹은 평가 결과는 부분안전계수(Partial Safety Factor, PSF)의 형태로 도출된다. 따라서 부분안전계수는 가동 기간 중 목표파손확률 기반 설계 및 평가를 위한 핵심 요소 가운데 하나이다. 본 연구에서는 특정 목표파손확률하에서 원주방향 관통균열이 존재하는 배관의 탄소성 균열개시 조건에 대한 부분안전계수 계산 기법을 정립하고 각 평가 인자가 균열개시에 미치는 중요도를 정량적으로 평가하였다. 균열 배관의 J-적분은 GE/EPRI법과 참조응력법으로 계산하였으며, 부분안전계수는 일차 및 이차신뢰도지수법으로 계산하였다. 또한 재료물성치의 통계적 분포 특성이 미치는 영향도 함께 평가하였다. Efforts are presently underway for developing an optimal design methodology for GEN-IV nuclear reactors based on target failure probabilities. A typical example is the system-based code, in which the results are represented in the form of partial safety factors (PSFs). Thus, a PSF is one of the crucial elements in either component design or integrity assessment based on target failure probabilities during the operation period. In the present study, a procedure for calculating the PSF of a circumferential through-wall cracked pipe based on the elastic-plastic crack initiation criterion is established, in which the importance of each input variable is assessed. Elastic-plastic J-integrals are calculated using the GE/EPRI and reference stress methods, and the PSF values are calculated using both first- and second-order reliability methods. Moreover, the effect of statistical distributions of assessment variables on the PSF is also evaluated.
이재빈 ( Jae Bin Lee ),우혜경 ( Hyekyung Woo ) 한국보건정보통계학회 2020 보건정보통계학회지 Vol.45 No.1
Objectives: Considering the limited resources, identification of the factors affecting length of stay (LOS) is of great value to determine the efficiency and optimal use of hospital resources. This study aimed to identify the LOS and the factors affecting the LOS for patients with ischemic heart disease. Methods: The Korean National Hospital Discharge In-depth Injury Survey Data (2017) collected by the Korea Centers for Disease Control and Prevention were used. We extracted 5,845 inpatients who principal diagnosis is ischemic heart disease. The factors affecting the LOS were identified through multiple regression analyses based on demographic, medical use, and disease characteristics. Results: The mean of the LOS was 4.27 days (standard deviation=7.97). The LOS was longer in women, elderly people, and medical aids recipients. Also, the results showed that the LOS has a significant relationship with the variables of type of admission (emergency), hospital residence (Seoul & metropolitan city), the number of beds (100 to 499 beds), surgery status (patients who underwent coronary procedure including coronary artery bypass grafting), the CCI severity and Primary diagnosis (acute myocardial infarction). Conclusions: This study found determinants of LOS for patients with ischemic heart disease include demographic, medical use, and disease characteristics. The identification of such factors could assist in optimizing patient LOS.