천무 발사대와 복합항법장치의 정렬절차 개선을 위한 연구
배공명,이시호,김성광,강태우,Bae, Gong-Myeong,Lee, See Ho,Kim, Sung-Kwang,Kang, Taewoo 한국군사과학기술학회 2018 한국군사과학기술학회지 Vol.21 No.3
Boresight process is to match the misalignment between PNU(Position Navigation Unit) and the reference axis of K-MLRS cage. It is important process to ensure accuracy of K-MLRS. When PNU is removed from cage in the previous alignment procedure, there is a misalignment angle with cage of K-MLRS during reassembly process. Therefore, boresight process is always need to align reference axes between PNU and K-MLRS cage. However, this study has proposed the case alignment process that it enable to correspond to reference axes between ISA (Inertial Sensor Assembly) block and PNU case. So, improved alignment procedure enables to install PNU in the reassembly process without additional boresight process.