Wind Analysis and Site Assessment for Test Site of 3MW Wind Power System
우상우(Woo, Sangwoo),이기학(Lee, Ki-Hak),이상일(Lee, Sang-Il),박종포(Park, Jong-Po) 한국신재생에너지학회 2011 한국신재생에너지학회 학술대회논문집 Vol.2011 No.11
A wind turbine power performance test is very important to wind turbine manufacturers because a wind farm developer or planner must want to define power performance characteristics and reliability of new wind turbines. Based on the IEC 61400-12-1, A wind turbine test site has to be nicely installed at flat terrain for testing. We are developing the wind power system which is IEC wind class IIa model with rated power of 3MW. KEPCO's Gochang power testing center was considered as candidates to build the test site without site calibration. This paper aims to verify the validity of the test site by using implement site assessment result that was based on IEC 61400-12-1.