http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
해상부이 데이터 분석을 통한 한반도 해역의 바람자원 평가
오기용(Oh, Ki-Yong),김지영(Kim, Ji-Young),이준신(Lee, Jun-Shin) 한국신재생에너지학회 2011 신재생에너지 Vol.7 No.1
In recent years, many countries have been endeavoring to exploit the offshore wind energy in terms of overcoming the limitations of on-land wind energy. Considering that mountains cover 70 percent of the Korean Peninsula and arable plains for wind energy are negligibly small, Korean government aggressively drives the offshore wind development of the Korean Peninsula. As part of preliminary investigation of offshore wind resources, KEPCO-RI (Korea Electric Power Corporation-Research Institute) has been analyzing marine buoy datasets measured at 5 positions over the period of 12 years, including estimation of extreme wind speed. It can be observed that variation of yearly wind speed, monthly wind speed as well as frequency distribution of wind direction. Wind classes of buoy sites are estimated by extrapolated average wind speed using log law. In addition, wind turbine class based on IEC code is assessed for evaluation of suitable wind turbine.
오기용(Oh, Ki-Yong),이준신(Lee, Jun-Shin),박준영(Park, Joon-Young),이재경(Lee, Jae-Kyung),김지영(Kim, Ji-Young) 한국신재생에너지학회 2009 신재생에너지 Vol.5 No.2
The performance test of a wind turbine in a wind farm is generally carried out by the owner to verify the power curve of the wind turbine given by the turbine manufacturer. The international electro-technical commission provides the IEC 61400-12-1 standard on Power performance measurements of electricity producing wind turbines. By using this code, one can easily find the suitable met-mast (meteorological mast) location for the wind data whether a wind farm is potential or already built. In this paper, the valid sectors for wind turbines installed in the HanKyoung wind farm, south-west in Jeju island are analyzed on the basis of the code by considering the wind farm layout. Among these sectors, the optimal met-mast location is presented for the power curve verification of the wind farm.
퍼지 로직 및 모델 예측 제어기 적용을 통한 초초임계압 화력발전소 부하 응답 최적화 운전 방법 설계
吳沂鏞(Ki-Yong Oh),金好烈(Ho-Yol Kim) 대한전기학회 2008 전기학회논문지 Vol.57 No.12
Even though efficiency of coal-fired power plant is proportional to operating temperature, increasement of operating temperature is limited by a technological level of each power plant component. It is an alternative plan to increase operating pressure up to ultra super critical point for efficiency enhancement. It is difficult to control process of power plant in ultra super critical point because that point has highly nonlinear characteristics. In this paper, new control logic, Unit Response Optimizer Controller (URO Controller) which is based on Fuzzy logic and Model Predictive Controller, is introduced for better performance. Then its performance is tested and analyzed with design guideline.
오기용(Ki-Yong Oh),박준영(Joon-Young Park),이재경(Jae-Kyung Lee) 대한전기학회 2008 대한전기학회 학술대회 논문집 Vol.2008 No.10
송전선로에 절연물로 사용되는 애자는 설치 이후 장시간 사용에 따라 고전압 스트레스, 기계적 스트레스, 열 및 환경 스트레스 등으로 열화가 진행되기 때문에 안정적인 전력설비 운영을 위하여 활선 애자의 비파괴 열화 상태 점검이 필요하다. 본 연구에서는 비파괴 상태 진단 감시 기술인 주파수 응답 함수 측정을 통한 고유 진동수 분석을 통하여 현재 활선 애자로 사용되고 있는 NGK210, KRI210, NGK300 및 KRI300 4가지 종류 애자의 동특성 실험을 수행하였으며, 이를 통하여 애자의 결함이 발생하였을 때 고유진동수 변화를 분석하였다.