냉각수 급수온도에 따른 직팽식 AHU-수랭식 VRF 민감도 분석
연상훈(Sang Hun Yeon),이제헌(Je Hveon Lee),문진우(Jin Woo Moon),이광호(Kwang Ho Lee) 대한설비공학회 2017 대한설비공학회 학술발표대회논문집 Vol.2017 No.6
Recently, VRF(Variable Refrigerant Flow) system has been attracting attention in commercial buildings due to its energy efficiency and capability to control characteristics and load of each room. VRF heat pump system can be actively controled under part load operation and it is possible to control the flow rate of the refrigerant individually according to the load by connecting a large number of indoor units to a single outdoor unit. This study is to assess a direct expansion (DX) air handling unit (AHU)-water source VRF system through co-simulation between EnergyPlus and Matlab and to perform the sensitivity analysis of cooling energy depending on the entering condenser fluid temperature. As a result, when condenser fluid temperature was elevated from 28 ℃ to 34 ℃, there was a tradeoff between outdoor unit energy reduction and cooling tower energy increase and thus the total cooling energy variation was only around 4%.
장의 급성 이식편대숙주병에서 대변미생물무리이식을 시행한 2예
연상훈 ( Sang Hoon Yeon ),이명원 ( Myung-won Lee ),조덕연 ( Deog-Yeon Jo ),허부연 ( Bu-Yeon Heo ),권재열 ( Jaeyul Kwon ),송익찬 ( Ik-Chan Song ) 대한내과학회 2021 대한내과학회지 Vol.96 No.4
급성 이식편대숙주병은 동종 조혈모세포이식의 비-재발(non-relapse) 사망률과 연관되어 있는 중요한 합병증 중 하나이다. 대변미생물무리이식을 통해 장의 미생물무리를 복원함으로써 장의 이식편대숙주병을 치료하려는 노력이 시도되고 있다. 저자들은 장의 스테로이드 불응 이식편대숙주병이 있는 환자 2명에게 대변미생물무리이식을 시행한 경험을 문헌고찰과 함께 보고하고자 한다. 첫 번째 증례는 43세 남자로 형제로부터 동종 조혈모세포이식을 받았고, 두 번째는 70세 여자로 아들로부터 사람백혈구항원 반일치 조혈모세포이식을 받았다. 두 환자는 각각 이식 후 7주 및 4주째에 급성 이식편대숙주병이 장에 발생하였다. 두 환자 모두에서 조혈모세포이식의 공여자로부터 대변을 제공받아 대변미생물무리이식을 시행하였다. 이후, 두 환자 모두에서 임상적인 증상의 호전을 보였으며, 첫 번째 환자는 완전 반응을, 두 번째 환자에서는 부분 반응을 보였다. RNA 염기서열 분석을 통해 대변미생물무리이식 전과 후의 대변을 분석하였을 때 대변 미생물무리이식 후 미생물무리의 다양성이 회복되는 것이 관찰되었다. 이로써 동종 조혈모세포이식 후에 발생하는 장의 스테로이드 불응-급성 이식편대숙주병의 치료 방법으로 대변미생물무리이식을 적극적으로 고려해야 하겠다. Restoring the microbiota via fecal microbiota transplantation (FMT) can be an effective treatment for steroid-refractory acute graft-versus-host disease (GVHD) of the gut. Here, we report two adult patients who underwent FMT to treat steroid-refractory acute GVHD of the gut. The first patient was a 43-year-old man who underwent allogeneic hematopoietic stem cell transplantation (HSCT) with cells from a matched sibling donor. The second patient was a 70-year-old woman who underwent haplo-identical HSCT with cells from her son. Gut GVHD developed at 7 and 4 weeks after HSCT, respectively. After undergoing FMT, the clinical symptoms improved; the first patient had a complete response and the second patient had a partial response. Microbial analyses using RNA gene sequencing showed that a diverse fecal microbiome was recovered by 4 weeks after FMT. FMT should be considered an effective therapeutic option for managing steroid-refractory acute GVHD of the gut. (Korean J Med 2021;96:358-362)
연상훈(Sang Hun Yeon),이광호(Kwang Ho Lee) 대한설비공학회 2018 설비공학 논문집 Vol.30 No.6
An underfloor air distribution (UFAD) system is an air conditioning system that enables the maintenance of indoor temperature with a relatively small supply-return air temperature gap and at a low supply air flow rate. UFAD offers a variety of advantages compared to conventional overhead systems, including improvements in comfort, health, work efficiency, indoor air quality, and ventilation efficiency for occupants, and improvements in life cycle cost decrease and lay-out flexibility for building services. In addition, using a UFAD system reduces the floor height because the duct space becomes unnecessary. A key factor for the improved energy performance of the UFAD system is stratification, which refers to the inconsistent vertical temperature distribution from the floor to the ceiling resulting from the buoyant effect of air. Stratification plays a critical role in determining the heat, ventilation, and energy performance of a system. However, based on a domestic literature review, research into the stratification of UFAD is insufficient, reflected by a lack of understanding of stratification and a lack of detailed research related to UFAD. Therefore, this study, by using the EnergyPlus simulation and Phi-Gamma formula, aims to assess variations in stratification according to diffuser condition.
UFAD 급기구의 유효면적 변화에 따른 온도 성층화 및 에너지 성능평가
연상훈(Sang-hun Yeon),손정은(Jeong-Eun Son),이광호(Kwang Ho Lee) 대한설비공학회 2016 대한설비공학회 학술발표대회논문집 Vol.2016 No.6
Recently tendency to introduce a UFAD system for environmentally friendly buildings as an alternative to OH systems clearly increased. Also LEED which is a green building certification system developed by the U.S. Green Building Council proposes UFAD to be the system having improved control and efficiency. Room air stratification is a key feature for energy saving in UFAD systems. It is a vertical temperature distribution due to the difference in relative density of the air, which separates occupied space ino lower occupied zone and upper mixed zone in EnergyPlus. The upper mixed zones do not need to be conditioned and thus air stratification has great potentials to reduce HVAC energy in UFAD. This study, by using the Phi-Gamma formula, aims at assessment of the energy performance and temperature stratification according to the size of a design effective area of diffuser. As a result, stratification was improved with an increase in the effective area of diffuser and thus cooling load was reduced during the summer. However, the energy saving effect was insignificant due to the fact that the mixed air temperature is increased despite the reduction of AHU supply air volume.
폐 폴리머 콘크리트 및 모르터를 골재로 사용한 폴리머 콘크리트의 특성
연규석 ( Kyuseok Yeon ),현상훈 ( Sanghoon Hyun ),손승완 ( Seungwan Son ),차진윤 ( Jinyun Cha ) 한국농공학회 2010 한국농공학회 학술대회초록집 Vol.2010 No.-
최근 폴리머 콘크리트는 프리캐스트 제품용으로 다양하게 생산·이용되고 있다. 폴리머 콘크리트의 수요가 많아짐에 따라 그에 따른 폐기물 처리문제가 야기된다. 폴리머 콘크리트는 부식에 대한 저항성이 강해 자연적 분해를 기대할 수 없으며 결합재인 수지의 비싼 가격이 구조물 적용에 걸림돌이 되어왔다. 이러한 점에서 볼 때 폐 폴리머 콘크리트의 재활용에 대한 연구가 필요하다. 본 연구는 불량한 폴리머 콘크리트 제품을 파쇄하여 얻어진 골재를 사용하여 폴리머 콘크리트 제조에 재활용함으로써 환경적 부담을 줄이는데 목적이 있다. 실험은 파쇄한 폐 폴리머 콘크리트와 모르터를 골재로 사용한 폴리머 콘크리트에 대하여 압축강도, 휨강도, 인장강도, 탄성계수, 포아송 비 등을 시험하고 기존의 폴리머 콘크리트에 대한 시험결과와 비교하였던 바 유의수를 5% 범위 내에서 유의성을 보여 충분한 재활용의 가치가 있는 것으로 확인되었다.
연규석 ( Kyuseok Yeon ),현상훈 ( Sanghoon Hyun ),손승완 ( Seungwan Son ),차진윤 ( Jinyun Cha ) 한국농공학회 2010 한국농공학회 학술대회초록집 Vol.2010 No.-
폴리머 모르타르는 내동결융해 및 내부식성 등 내구성이 우수하며, 압축ㆍ휨ㆍ인장강도가 우수하다. 또한 계절에 따른 온도변화에 저항력이 강하고 경화시간이 시멘트 콘크리트에 비해 빠르기 때문에 열악한 환경 조건에서의 구조재로서 매우 유리하다. 따라서 본 연구는 불포화 폴리에스터를 MMA로 개질한 폴리머 모르타르의 저온에서의 경화 및 강도 발현 특성에 대해 연구하였다. 결합재와 모르타르의 시험온도는 20, 5, 0, -5, -10, -20℃로 촉진제에 따른 수지와 모르타르의 가사시간을 구명하였고, 그에 관한 상관관계식을 도출하여 온도별 촉진제에 따른 가사시간을 예측할 수 있었다. 양생온도에 따른 각각의 강도 시험은 모르타르의 가사시간 측정을 통해 얻은 결과를 바탕으로 개시제 1.5%, 촉진제 2%를 사용하였으며, 추가 변수로 상온(20℃)과 저온(5, 0, -5, -10, -20 ℃)에서 보관한 재료를 사용하요시간별(3, 6, 12, 24, 48, 72, 120, 168 시간) 강도 시험을 실시하였다. 연구결과 상온(20 ℃)에 보관된 재료로 제작한 시험체에 비해 저온(0, -10, -20 ℃)보관된 시험체의 압축강도는 20 - 25 %, 휨강도는 5 - 15 %, 인장강도는 6 - 13 %의 강도 저하가 나타났다. 또한 온도에 관계없이 모든 시험체의 강도값은 24 시간 내에 7일(168시간)강도의 70 %이상 발현하였다. 그러나 저온에서 양생된 시험체는 상온에 비해 압축강도는 30 %, 인장강도는 50 %, 휨강도는 30 %로 상대적으로 낮은 값을 보였다.