http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
신윤섭 ( Yun Sup Shin ),박진무 ( Jin Moo Park ),이정욱 ( Jeong Uk Lee ),정미현 ( Mi Hyun Jeong ),서정교 ( Jeong Kyo Seo ),최인호 ( In Ho Choi ) 정보저장시스템학회 2005 추계학술대회논문집 Vol.2005 No.-
Air gap control method using a conventional actuator for near field recording technology has been reported. Toachieve good performance in the air gap servo and further experiments, the assembling between OL and SIL is the critical procedure. A lens set with NA 1.45 at 405 nm has been assembled and tested by using a Twyman-Green interferometer. The tolerance of assembling is very tight and the designing and adjusting adjusting procedure must be carefully controlled.
콘 관입저항치를 이용한 수직배수재 타설심도 결정에 관한 연구
김연정,김남호,신윤섭,Kim, Yeon-Jung,Kim, Nam-Ho,Shin Yun-Sup (사)한국토질및기초기술사회 2006 기술발표회 Vol.2006 No.-
최근 피조콘시험은 과거 일반적으로 사용되었던 표준관입시험과 함께 연약지반의 특성을 평가하기 위해 빈번히 사용되고 있다. 본 연구에서는 하부지반의 지층상태를 파악하고 설계를 위한 연약지반 심도 결정 및 시공시 수직배수재 타설심도 결정시 그 신뢰도를 향상시키기 위해서 표준관입시험결과(N치), 선행압밀하중(pc), 수직배수재 타설시 관입에너지와 피조콘시험을 통한 콘 관입저항치($q_c$)와의 관계를 분석하였다. 대상 지역별로 일정한 표준관입저항치를 기준으로 평균 연약지반심도를 결정하여, 동일한 심도에서 피조콘관입저항치를 값을 분석한 결과 $q_c$=(1.09~1.63)N, 선행압밀하중을 고려한 결과 $q_c$=(1.21~1.98)N의 관계를 나타내었다. 또한 수직배수재 타설시 관입에너지와 피조콘시험을 통한 콘 관입저항치($q_c$)와의 관계를 분석한 결과 평균적으로 피조콘 관입저항치 10kgf/$cm^2$의 경우 수직배수재 타설 시 관입저항치는 약 65~70.0kgf/$cm^2$의 값을 나타내였다. Recently, piezocone penetration test is frequently used in order to estimate the characteristics of soft ground with standard penetration test; generally used in the past In this study, standard penetration test, piezocone penetration test, driving resistance of vertical drain were used in order to increase the confidence for determination of soft ground depth. And the compressible layer was determined by the comparison between the preconsolidation pressure and the designed increase pressure. As the results, the relation between standard penetration test and piezocone penetration test shows $q_c$=(1.09~1.63)N at the soft ground, determined by 5/30 N value. And $q_c$(1.21~1.98)N was shown at the point of compressible layer, evaluated by the preconsolidation pressure. And driving resistance of vertical drain is 70 f/$cm^2$ which is equal to 10kgf/$cm^2$ cone penetration resistance.
이정욱 ( Jeong Uk Lee ),서정교 ( Jeong Kyo Seo ),신윤섭 ( Yun Sup Shin ),박진무 ( Jin Moo Park ),정미현 ( Mi Hyeon Jeong ),최인호 ( In Ho Choi ) 정보저장시스템학회 2005 추계학술대회논문집 Vol.2005 No.-
Near field recording (NFR) technology with SIL has been thought as the most promising generation optical storage device. A gap distance between the SIL and the disc should be controlled to be 20~40nm. We observed gap error signal in our NFR test-bed using a blue LD (405nm). The digital gap servo filter and control algorithm were developed to maintain a constant air gap by adopting a conventional actuator.