MCMB is the most commonly used anode for lithium-ion secondary cell. Good MCMB charge/discharge cycle stability is one of the most important criteria for reliable and long-lived lithium-ion battery operation. In this study, the cycling stability of a lithium-ion secondary cell have been studied. MCMB was made by the directly solvent extraction method. After the MCMB is formed by heat treatment the measurement of capacity and efficiency were carried out.
방사선원과 감마카메라 사이에 위치한 산란매질이 소형 감마카메라 영상에 미치는 영향 연구
서현관,최용,임기천,우상근,이준수,송태용,최연성,이경한,김병태,최영일,Seo, Hyun-Kwan,Choi, Yong,Im, Ki-Chun,Woo, Sang-Geun,Lee, Jun-Soo,Song, Tae-Yong,Choi, Yeon-Sung,Lee, Kyung-Han,Kim, Byung-Tae,Choi, Young-Il 한국의학물리학회 2002 의학물리 Vol.13 No.1
방사선원과 감마카메라 사이에 위치한 산란매질의 종류, 두께 그리고 조준기 종류가 감마카메라 영상에 미치는 영향을 고찰하기 위하여 실험과 시뮬레이션을 수행하였다. 감마카메라는 조준기, NaI(T1) 섬광결정(60$\times$60$\times$6 ㎣), 위치민감형 광전자증배관(PSPMT), NIMs, 제어용 컴퓨터를 사용하여 개발하였다. 시뮬레이션은 산란매질(아크릴매질/공기)의 두께 변화(0~8 cm)와 조준기의 종류(평행구멍형조준기/확산형조준기) 변화에 따라 계산하였으며 실험 역시 시뮬레이션과 같은 조건으로 수행하였다. 시뮬레이션 결과를 보면, 매질의 두께가 0 cmn에서 8 cm로 증가하면, 계수율은 평행구멍형조준기의 경우 17%(공기), 60%(아크릴) 감소하였으며 확산형 조준기의 경우 감소율이 더 심하여 각각 86%(공기), 98%(아크릴)의 계수율 감소를 보였다. 실제 실험 결과도 시뮬레이션 결과와 비슷하게 매질의 두께가 0 cm에서 8 cm로 증가하면 평행구멍형조준기의 경우 계수율은 10%(공기), 54%(아크릴) 감소하였으며 확산형조준기의 경우 36%(공기), 63%(아크릴)의 계수율 감소를 보였다. 영상의 공간분해능 역시 매질의 두께가 증가할수록 저하되었다. 연구결과 소형 감마카메라를 임상적으로 사용하고자 할 때 감마카메라를 질환 부위에 최대한 밀착시키고 산란매질 두께를 최소화해야 고효율, 고분해능 영상을 얻을 수 있음을 확인하였다. Effect of scatter media materials and thickness, located between radioactivity and small gamma camera, on imaging characteristics was evaluated. The small gamma camera developed for breast imaging was consisted of collimator, NaI(T1) crystal(60$\times$60$\times$6 ㎣), PSPMT(position sensitive photomultimplier tube), NIMs and personal computer. Monte Carlo simulation was performed to evaluate the system sensitivity with different scatter media thickness(0~8 cm) and materials(air and acrylic) with parallel hole collimator and diverging collimator. The sensitivity and spatial resolution was measured using the small gamma camera with the same condition applied to the simulation. Counts was decreased by 10%(air) and 54%(acryl) with the parallel hole collimator and by 35%(air) and 63%(acryl) with the diverging collimator. Spatial resolution was decreased as increasing the thickness of scatter media. This study substantiate the importance of a gamma camera positioning and the minimization of the distance between detector and target lesion in the clinical application of a gamma camera.
전립선 치료용 고강도 집속 초음파(HIFU) 시스템을 위한 MR 호환 변환자 구동장치 시제품 성능 평가
서현관(Hyunkwan Seo),이규찬(Kyu-Chan Lee),신지연(Jiyeon Shin),정연재(Yeonjae Jeong),고광연(Kwangyeon Ko),오창현(Changhyun Oh),황성관(Sungkwan Hwang),김민영(Minyoung Kim),김희원(Heewon Kim),이정준(Jungjoon Lee),정영립(Yeonglip Jeong) 대한전기학회 2021 대한전기학회 학술대회 논문집 Vol.2021 No.10
고강도 집속 초음파 시스템(HIFU)은 체내 병변의 한 점에 초음파 에너지를 모아 섭씨 60~100도의 발열을 유발하여 양/악성 종양을 괴사시키는 원리로 치료하는 시술이다. HIFU 치료는 비침습적 시술이므로 고통이 최소화되고, 정상조직에 해를 주지 않으므로 부작용이 적은 장점이 있다. 전립선 치료를 위해 MRI 가이드 HIFU 시스템을 개발하고 있으며, 프로브를 직장에 삽입하여 HIFU를 전립선에 조사하는 방식이다. 볼륨을 가진 전립선 종양을 치료하기 위해 변환자를 미세하게 전/후진 및 회전하도록 해야 하며, MRI 환경하에서 사용되므로, MR 호환되는 변환자 구동장치가 필요하다. 이를 위해 공압으로 변환자를 구동하는 장치를 개발하였으며, 변환자 구동 정확도를 성능 평가한 결과를 발표한다.