http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
A Technical Planning for Emotion Evaluation of Art Performance using the Human Emotional Data
Hyo-Jung Moon(문효정),Hee-Kyung Ko(고희경),Young-Ho Park(박영호) 한국디지털콘텐츠학회 2017 한국디지털콘텐츠학회논문지 Vol.18 No.1
Recently, several kinds of researches using IoT wearable devices are active in the field of sports, design, emotional sciences and so on. The human bio data such as blood pulse, ECG, SKT signal, and GSR Signal producing from IoT wearable devices such as Watch, Smart-band, Grass can adapt to the meaningful future applications. Using the human’s emotional data and a physical status with variation and so on, we can individually get the personal status. Due to knowing the personal emotion or physical status is related and connected to the valuable wallet of customers, the approach is more important in nowadays. Therefore, the personal information can effectively adapt to the marketing of the culture industry, which deals with emotions of customers. The research shows implementation steps for explaining overall architecture of the convergence research between Art and Technologies.
채한욱,박재용,문효정,Chae, Han-Uk,Park, Jae-Yong,Moon, Hyo-Jung 한국환경보건학회 1999 한국환경보건학회지 Vol.25 No.3
For the purpose of inquiring into the actual conditions of water quality management of Simple Piped Water Supply(SPWS) and the satisfaction and attitudes of inhabitants about utilizing water-supply, this research was done through the questionnaires, the investigation of surrounding environment and water quality analysis in the Sangju city, Kyungsang-pookdo during 4 months from March to June, 1998. The fountainhead of SPES using ground water accounted for 65.3%, which was the highest rate in the group. Most of them was at least 10 years in the number of utilization year. 79.6% of them were exposed to many sorts of surrounding pollution origins. The examination of water was performed only through a test about water purification and 24.5% of them disinfection by chlorine also no residual chlorine was detected at all. All the waterworks did not have any education to the managers of water quality and 81.5% of them held physical examination. As a result of the water examination about SPWS, 65.3% of them were found incongruity and the valley and springing water accounted for higher than the underground water in the rate of incongruity. Looking into the details of the result in the water examination, a category of colon bacilli was ranked in the highest rate and the next one was general bacilli, nitric acid nitrogen and turbidity in order. In the satisfaction degree of the water quality, the satisfied accounted for 44.6%, and 29.2% each. Over the state of satisfaction about the ways of water examination, satisfaction accounted for 44.6%, and unsatisfaction 28.3%. Summarizing the result of the above-stated, the state of Water Quality Management of the SPWS was in a poor condition. Thus for the water Quality Management, systematic and scientific water Quality Management mainly by the administrative organization other than voluntary management by the village should be done beyond doubt. Additionally the opinions and demands of inhabitants utilizing the water supply have to be positively reflected in the affairs of water Quality Management so that the distrust of inhabitants to the SPWS should be settled.
김두희,장봉기,홍성철,문효정,이덕희,오혜주,Kim, Doo-Hie,Jang, Bong-Ki,Hong, Sung-Chul,Moon, Hyo-Jung,Lee, Duck-Hee,Oh, Hae-Ju 대한예방의학회 1993 예방의학회지 Vol.26 No.2
The aquatic quality of the Naktong river after two or three months in June, 1991 with phenol spillage from a electrical factory in Kumi was investigated. The samples were collected at six sites of the Naktong river basin and Kachang and Kongsan lakes. Phenol was not detected from all water samples. Turbidity was very much increased to the down stream in the Naktong river. The BOD and COD values exceeded the 2nd grade(3mg/l) of the Korean standard quality of Environmenal Water Act at the all sampling sites of the Naktong river. Especially, the value of COD at Kaejin (12.5mg/l) was poorly classified as to the 5th grade of water class for the environmental quality standards. Organophosphorous pesticides such as parathion, malathion, fenitrothion and diazinon were investigated but not detected. Diazinon was only detected at the Ilsan bridge(1.42ppb), Okkye stream(6.95ppb), Waekwan bridge(0.32ppb), Gangjung reservior(0.13ppb), Kaejin (0.05ppb). Of the carbamates such as carbanyl, isoprocarb and cabofuran, the carbofuran was detected all sites except tap water, and Kachang and Kongsan lakes. The content of heavy metals such as Cd, Pb, Zn, Fe, Mn, Hg were not exceeding for drinking water standards at the all sampling region, but only mecury was detected from Okkye stream(0.018ppb) and Kaejin (0.09ppb). In the regions of Kachang and Kongsan lakes, the content of heavy meatals were lower than that of reservior of Naktong river.