RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
          펼치기
        • 등재정보
        • 학술지명
          펼치기
        • 주제분류
        • 발행연도
          펼치기
        • 작성언어

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재후보

        화재에 대한 Extra-dosed 교 케이블의 안전성 평가

        봉조,용선,박원태 한국방재학회 2008 한국방재학회논문집 Vol.08 No.05

        Extra dosed bridge among the Cabled-stayed bridges have been increasingly built in korea in recently. But such bridges were often damaged by fire due to car collison. In this study Extra dosed bridges among the cabled-supported bridges are selected to analysis model frequently to be designed and/or constructed in recent and furture in this study. COSMOS FloWorks 2007 software are used for Heat Transfer Analysis and Thermal Stress Analysis. The safety of wire, HDPE pipe and stainless steel pipe are investigated. In the case of the constant of the temperature of the heat source, the significant three variables for the analysis are selected for study : (1) the distance between the fire-proof bulk head and the heat source, (2) wind velocity, (3) the height of the end of Stainless steel pipe. 최근 국내에서 케이블을 이용한 Extradosed 교 형식의 대교들이 건설되고 있다. 이러한 교량에서 자동차 충돌등으로 인한 화재에 의해 교량이 손상을 입는 사고가 발생되고 있어 화재에 대한 안정성해석이 필요하다. 본 연구에서는 케이블 교량형식 중 최근 국내에서 사용빈도가 높은 Extradosed 교 형식을 해석모델로 하였으며, 상용소프트웨어인 Solid Works 2007을 사용하여 모델링하고, COSMOS FloWorks 2007소프트웨어에 의한 열전달 해석 및 열응력 해석을 통하여 교량위 화재 발생시 와이어, 사재방재 파이프 및 그 주변에 대한 열유동 해석 및 사재방재 케이블의 안전을 검토하였다. 열원의 온도가 일정한 경우에 대해 다음 3개의 중요변수를 해석변수로 사용하였다. : (1)방호책과 열원사이의 거리, (2)풍속, (3) 스테인레스 강관의 끝단의 높이.

      • KCI등재후보

        화재에 대한 Extra-dosed교 케이블의 안전성 평가

        봉조,용선,박원태,Rhu. Bong-Jo,Song. Young-Sun,Park. Weon-Tae 한국방재학회 2008 한국방재학회논문집 Vol.8 No.5

        최근 국내에서 케이블을 이용한 Extradosed 교 형식의 대교들이 건설되고 있다. 이러한 교량에서 자동차 충돌등으로 인한 화재에 의해 교량이 손상을 입는 사고가 발생되고 있어 화재에 대한 안정성해석이 필요하다. 본 연구에서는 케이블 교량형식 중 최근 국내에서 사용빈도가 높은 Extradosed 교 형식을 해석모델로 하였으며, 상용소프트웨어인 Solid Works 2007을 사용하여 모델링하고, COSMOS FloWorks 2007소프트웨어에 의한 열전달 해석 및 열응력 해석을 통하여 교량위 화재 발생시 와이어, 사재방재 파이프 및 그 주변에 대한 열유동 해석 및 사재방재 케이블의 안전을 검토하였다. 열원의 온도가 일정한 경우에 대해 다음 3개의 중요변수를 해석변수로 사용하였다. : (1)방호책과 열원사이의 거리, (2)풍속, (3) 스테인레스 강관의 끝단의 높이. Extra dosed bridge among the Cabled-stayed bridges have been increasingly built in korea in recently. But such bridges were often damaged by fire due to car collison. In this study Extra dosed bridges among the cabled-supported bridges are selected to analysis model frequently to be designed and/or constructed in recent and furture in this study. COSMOS FloWorks 2007 software are used for Heat Transfer Analysis and Thermal Stress Analysis. The safety of wire, HDPE pipe and stainless steel pipe are investigated. In the case of the constant of the temperature of the heat source, the significant three variables for the analysis are selected for study : (1) the distance between the fire-proof bulk head and the heat source, (2) wind velocity, (3) the height of the end of Stainless steel pipe.

      • 차량화재로 인한 금가대교 케이블의 안전성 검토

        봉조(Bong-Jo Ryu),이강수(Kang-Soo Lee),신광복(Kwang-Bok Shin),오부진(Boo-Jin Oh),양승민(Seung-Min Yang),용선(Young-Sun Song) 대한기계학회 2007 대한기계학회 춘추학술대회 Vol.2007 No.10

        This paper deals with the safety investigation of Kumga bridge cables, stainless steel pipe and HDPE(High Density Poly-Ethylene) pipe due to a vehicle fire. Kumga bridge under construction is a cable-stayed bridge located at Chungju city. Heat source of a fire in the analysis is assumed to be a large bus. Through the transient analysis, the temperature and fluid distribution for cables, stainless steel pipes and HDPE pipes of the bridge are demonstrated. Commercial software SolidWorks and COSMOSFloWorks were used for three dimensional modeling of the bridge, thermal analysis and fluid analysis, respectively. The purpose of the study is to investigate the safety of cables and pipes of a Kumga bridge due to a fire through heat transfer analyses and fluid ones.

      • KCI등재후보

        고관절 및 습관절 수술전후의 폐색전증 발생빈도에 관한 연구

        용선(Yong Sun Ju),최승원(Seung Won Choi),김우성(Woo Sung Kim),김원동(Won Dong Kim),고윤석(Youn Suck Koh),이수호(Soo Ho Lee),조우신(Woo Shin Jo),김기용(Key Yong Kim),문대혁(Dae Hyuk Moon),진숙(Jin Sook Ryu),이명혜(Myeong Hye Lee) 대한내과학회 1994 대한내과학회지 Vol.47 No.1

        Background: Pulmonary embolism is common complication following orthopedic joint replacement procedures. The incidence of pulmonary embolism (PE) after elective hip or knee replacement has not been reported in Korean population. Methods: To find out the incidence of PE related to elective hip or knee replacement, we performed perfusion (QS) and ventilation scintigraphy (VS) preoperatively and postoperatively in 157 patients who underwent hip or knee replacement procedures, QS was performed preoperatively, and then again 7 days after surgery, VS was obtained within a day in patients with significant perfusion defects on QS using 99mTc-diethylenetriamine-pentacetic acid (DTPA) aerosol. PE was diagnosed either by pulmonary angiography, or by changing persusion pattern on sequential QS in case of high-probability scan. QS and VS were read according to PIOPED (Prospective Investigation of Pulmonary Embolism Diagnosis) criteria. Results: Among 157 preoperative studies, 5 high-and 6 intermediate-probablity scans were observed. Five patients with intermediate-probablity scan underwent pulmonary angiogrphy, and PE were confirmed in 3 patients. All 8 patients with PE (5 patients with high- probability scan and 3 confirmed patients by pulmonary angiography) were asymptomatic and showed improvement on QS after 7 days of heparin therapy. Of 146 patients, 12 patients (8.2%) showed significant changes from low-probability or normal scan to 5 high-and 7 intermediate-probability scans postoperatively, compared to preoperative QS. Among 7 patients with intermediate-probability, PE were confirmed in 4 patients by pulmonary angiography. Among 9 patients with PE, 7 patients showed improvement on QS after heparin therpy, and 1 patient did not undergo follow-up QS, and 1 patient died of hypoxic respiratory failure. In 9 patients with PE, 8 patients were asymptomatic. Conclusion: The incidence of PE following total hip or knee replacement was 6.1%(9/146). Preoperative prevalence of PE was 5.1%(8/157). Combination of preand past-operative scintigraphic imaging is a useful diagnostic modality for screening PE, because most patients are not clinically suspected.

      • KCI등재

        PCB 産業에서 배출되는 산성 염화동 폐액으로부터 입자형상이 제어된 산화동 회수에 관한 연구

        김영희,도형,김수룡,용선 한국자원리싸이클링학회 2001 資源 리싸이클링 Vol.10 No.6

        구리를 포함하는 산성 염화동 폐액으로부터 입자형상이 제어된 고순도의 산화동을 중화법을 사용하여 제조하였다 PCB(Printed Circuit Board)제조 산업은 구리 소재를 이용한 전자 부품 가공 산업으로서 제조 공정인 부식 과정에서 다량의 구리가 함유된 에칭 폐액이 발생한다. 환경과 경제적인 측면에서 폐액으로부터 구리성분을 재회수하는 기술의 개발은 매우 중요하다. 본 연구에서는 폐액으로부터 산화동을 회수하는 공정 중 반응 온도를 조절하여 생성물의 입자 크기와 형상을 제어하였다. $40 ^{\circ}C$미만에서 회수한산화동은 입자모양이 침상이었으며 $40^{\circ}C$이상에서 회수한 산화동은 판상을 보여 주었다. 생성물의 물리적 특성을 SEM, XRD, TGA그리고 원자 흡수 분광기를 사용하여 분석하였다. Shape-controlled copper oxides have been recovered from copper-containing waste etchant by neutralization with alkalihydroxide. Large amount of copper-containing waste etchant is generated from Printed Circuit Board industry. In an environmental and economic point of view, retrieve of the valuable natural resource from the waste is important. In recycling process of copper oxide from the waste etchant, reaction temperature controls shapes and sizes of the products. Copper oxide recovered below reaction temperature $40^{\circ}C$ was of a needle shape, while copper oxide comes in a platy shape above $40 ^{\circ}C$ . Physical properties of samples have been characterized using SEM, XRD, TGA and Atomic absorption spectroscopy.

      • KCI등재

        체외순환 없이 시행한 관상동맥 우회로 조성술 후 부신성 위기

        안병희,용선,상완,홍성범,정명호,김상형 대한흉부외과학회 2004 Journal of Chest Surgery (J Chest Surg) Vol.37 No.7

        Addisonian crisis, also commonly referred to as adrenal crisis, occurs when the cortisol produced by the adrenal gland is insufficient to meet the body's needs. Pituitary apoplexy usually occurs as hemorrhagic and ischemic necrosis in the presence of a pre-existing pituitary adenoma, and is a rare sequela of cardiovascular surgery. Most pituitary apoplexy that happens in cardiovascular surgery has been known to be related to harmful effects of the cardiopulmonary bypass. The case presented herein illustrates occult pituitary apoplexy that occurred after off-pump coronary artery bypass grafting. In this patient, the initial signs of addisonian crisis was similar to those of septic shock, and were overlooked. However, once recognized, they were reduced dramatically with standard stress-dose cortisone. 부신성 위기라 불리는 Addisonian crisis는 스트레스 호르몬의 일종인 cortisol이 분비되어야 하는 상황에서 정상적으로 분비되지 못함으로써 발생한다. 뇌하수체 졸중은 기존에 있던 뇌하수체 선종이 어떤 원인에 의해 출혈성 또는 허혈성 변성에 의해 발생하는 것으로 알려져 있으며 심혈관계 수술에 있어 매우 드문 합병증이다. 더구나 심혈관계 수술에서 발생하는 대부분의 뇌하수체 졸중은 체외순환과 연관이 있는 것으로 알려져 있다. 본 증례는 체회순환 없이 시행한 관상동맥 우회로 조성술 후에 뇌하수체 졸중이 발생한 경우로 처음 보였던 여러 증상이 마치 폐혈성 쇼크와 유사하여 진단이 늦어지게 되었다. 그러나 일단 진단이 된 후에는 스트레스 용량의 부신 호르몬을 투여함으로써 급격한 증상 호전을 보였다.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼