http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
20대 정상성인의 발목에 부가된 하중이 보행중 에너지 소모도에 미치는 영향
김용건,한동욱,Kim, Yong-Gun,Han, Dong-Uck 대한물리치료과학회 2000 대한물리치료과학회지 Vol.7 No.1
80 persons who don't have past history of cardiopulmonary and neuromuscular disease. The results were as follow; 1. PCI(Physiological Cost Index) value without loading to ankle were significantly increased compared to 1kg, and 2kg (p<0.01). 2. Female Subjects showed more increased PCI value in without loading and lkg, 2kg loading compared to male subjects (p<0.01). 3. In every PCI condition the difference among height groups was observed (p<0.01). 4. The difference among weight groups in each PCI condition was observed (p<0.01). These results showed that energy consumption was increased according to loading on the ankle during gait so weight of orthosis or prosthesis must be considered when choosing them and during gait training with these ones.
김용건,이규복,Kim, Yong-Gun,Lee, Kyu-Bok Korean Academy of Stomatognathic Function and Occl 2018 구강회복응용과학지 Vol.34 No.2
목적: 임플란트 표면의 특성과 임플란트 디자인은 성공적인 초기 고정을 얻는데 중요한 변수이다. 이 연구의 목적은 치유기간 동안 테이퍼드 직선형 디자인을 가진 SLA (Sandblasted and Acid-etched) 임플란트의 ISQ (Implant Stability Quotient) 값을 측정하고 임플란트의 안정성에 미치는 영향을 평가하는 것이다. 연구 재료 및 방법: 임플란트의 안정성을 측정하기 위하여 26명의 환자(여자 13명, 남자 13명)의 44개 임플란트에 대한 자기공명주파수분석(Resonance Frequency Analysis)을 실시하였다. 골질 및 골량에 대한 임상적 평가는 Lekholm & Zarb (1985)의 기준에 따라 시행하였다. 시간경과에 따른 임플란트 안정성변화(총 ISQ 값)를 고정체 식립 시 그리고 12주후 치유지대주 연결 시 측정하고 RFA와 식립토크, RFA와 골질, RFA와 상, 하악골 사이의 상관관계를 평가하였다. 결과: 임플란트의 평균 ISQ값은 임플란트 식립 당시(기준선) $69.4{\pm}10.2$, 치유지대주연결에서(두번째수술) $81.4{\pm}6.9$였다(P < 0.05). RFA와 골질, RFA와 상하악골 사이에 유의한 차이가 있었다(P < 0.05). RFA와 식립토크, 식립부위, 고정체 직경, 임플란트 길이 사이에는 유의한 차이가 없었다(P > 0.05). 결론: 본 연구의 제한된 범위내에서 테이퍼드 직선형 디자인을 가진 SLA 임플란트의 ISQ값은 고정체 식립시와 치유지대주 연결 시 모두 높은 값을 보였다. 따라서 테이퍼드 직선형 디자인을 가진 SLA 임플란트는 초기안정성 및 2차 안정성을 향상시킬 수 있으며, 즉시 또는 초기하중을 적용할 수 있을것으로 사료된다. Purpose: Implant surface modification and implant design are the principle targets for achieving successful primary stability. The aim of this study was to measure implant stability quotient (ISQ) values of sandblasted, large-grit, acid-etched (SLA) implants with tapered straight body design during the healing period, and to determine the various factors affecting implant stability. Materials and Methods: To measure implant stability, resonance frequency analysis (RFA) was performed in 26 patients (13 women and 13 men) with 44 SLA implants with tapered straight body design. Implant stability (ISQ values) was evaluated at baseline and healing abutment connection (12 weeks), and the correlations between RFA and insertion torque (IT), bone quality, and jawbone were determined. Results: The mean ISQ value of the implants was $69.4{\pm}10.2$ at the time of implant placement (baseline) and $81.4{\pm}6.9$ at the time of healing abutment connection (P < 0.05). Significant differences were found between RFA and bone quality and between RFA and jawbone (P < 0.05). No significant differences were found between RFA and IT, insertion area, fixture diameter, and implant length (P > 0.05). Conclusion: ISQ values of SLA implants with tapered straight body design were high at baseline and healing abutment connection. It was concluded that SLA implants with tapered straight body design show improved primary and secondary stability, and that immediate or early loading may be applicable.
덮개 나사 조기 노출이 임플란트의 생존율에 미치는 영향
김용건,이재관,장범석,엄흥식,Kim, Yong-Gun,Lee, Jae-Kwan,Chang, Beom-Seok,Um, Heung-Sik 대한치주과학회 2006 Journal of Periodontal & Implant Science Vol.36 No.4
The early exposure of cover screws is a common complication of 2-stage implant technique. The exposure of cover screws between stage I and IT surgery may cause inflammation in the soft tissues surrounding the implants, and lead to peri-implantitis or marginal bone loss. The purpose of this study was to evaluate the effect of the early exposure of cover screws on implants placed using 2-stage technique. Two hundred and nineteen implants in 77 patients were examined for cumulative survival rate, radiographic marginal bone level change, cause and frequency of the early exposure. The results were as follows: 1. Twenty-five implants showed early exposure of cover screws with a frequency of 11.4%. 2. Cumulative survival rate of the implants with early cover screw exposure was 88.0%, and that of the implants without cover screw exposure was 96,9%. 3. At the time of stage IT surgery and 1 year after loading, the marginal bone loss was greater around the implants with early exposure of cover screws than around the implants without cover screw exposure(p <0.05), 4, There was no statistically significant difference in the frequency of the early exposure according to the implant diameter, gender, and smoking(p >0,05).
김용건(Yong-Gun Kim),이재목(Jae-Mok Lee) 대한치과의사협회 2014 대한치과의사협회지 Vol.52 No.7
Peri implant diseases are inflammatory lesions, which include peri implant mucositis and peri implantitis. Peri implant mucositis is described as the presence of inflammation in the mucosa around implants without any bone loss. By contrast, in peri implantitis, besides the inflammation in the peri implant mucosa, loss of supporting bone is also seen. Diagnosis of peri implant diseases require the use of gentle probing(0.2 ~ 0.3N) to identify the presence of bleeding on probing, probing depth and suppuration, both signs of clinical inflammation. Radiographs are required to detect loss of supporting bone. Baseline probing measurements and high quality, long cone periapical radiographs should be obtained once the restoration of the implant is completed to make possible longitudinal monitoring of peri implant tissue.